Permit Application Status

PRRES20204442


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204442
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - FINISHED BASEMENT - COVERED DECK
11/23/2020
12/17/2020
10/07/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/30/2020 12/17/2020
Dylan Eppert
Planning Review (RES) Approved 12/18/2020 12/16/2020
Shannon McGuire
Residential Plan Review Approved 11/30/2020 11/30/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $913.42 $913.42 Paid 12/17/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 12/17/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/17/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/17/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/17/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/17/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 08/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/12/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/12/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 08/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 1/14/2021 01/14/2021
Misc
Informational
01/14/2021
- (3) 30 X 36 PIERS POURED WITH FOOTING -
Footing Inspection - Residential Passed 1/14/2021 01/14/2021
Misc
Informational
01/14/2021
- UFER REAR GARAGE FOUNDATION WALL -
Sewer Service Inspection - R Passed 2/5/2021 (9:45) 2/5/2021 02/05/2021
Underslab Plumbing Inspection - Residential Failed 2/8/2021 2/8/2021 02/08/2021
Misc
Corrective Action Required
02/08/2021
Complete interior underslab drain tile installation
Erosion Control Inspection Residential Failed 02/08/2021
Misc
Corrective Action Required
02/08/2021
-Erosion control requires continuous maintenance. Repair damaged sections at curb and establish methods rear of lot within 48 hours -provide and maintain gravel filter -no further inspections until issues are resolved
Underslab Plumbing Inspection - Residential Failed 2/19/2021 2/19/2021 02/19/2021
Misc
Corrective Action Required
02/08/2021
Complete interior underslab drain tile installation
Misc
Corrective Action Required
02/19/2021
- BASEMENT COVERED WITH TARP EXPOSE DRAIN TILE FOR INSPECTION -
Underslab Plumbing Inspection - Residential Failed 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
02/19/2021
Complete interior underslab drain tile installation
Misc
Resolved
02/23/2021
Misc
Corrective Action Required
02/23/2021
Complete connection of drain tile to sump
Underslab Plumbing Inspection - Residential Passed 2/24/2021 2/24/2021 02/24/2021
Misc
Resolved
02/24/2021
Misc
Resolved
02/24/2021
Water Service Inspection - R Passed 2/24/2021 (1:00) 2/24/2021 02/24/2021
All Rough Inspection - Residential Failed 4/16/2021 4/16/2021 04/16/2021
Miscellaneous Correction
Corrective Action Required
04/16/2021
House not ready for inspection this list was made without looking at plans or truss package list subject to change after trade make corrections complete below list and call for reinspect Fire blocking fireplace Seal penetration bottom plate master water closet Expose H2.5s deck Provide H2.5 or truss screws garage Provide truss screws double girder truss Provide 1 1/2 bearing girder truss at single car both ends Fire blocking at b vent laundry Fire stopping at beams Over bored joist above basement stairs Provide anchor bolts within 12" of plate breaks basement Support gas line per code Support DWV every 4' NE bed basement Seal upward penetrations throughout !!!!! Provide double joist hangers deck at fireplace Strap header at windows under deck Strap Corner at beam under deck Tighten anchor bolts throughout Provide truss screws above front door Tie top plate together above front door Secure gas line fire place Support header covered deck ( remove plywood expose king studs) Nail corner studs per code Roof vents partially covered Provide 5/8 anchor bolts PFH portal garage Fire blocking basement furr outs Comply with fire resistance rating for exterior wall/projections less than 5' from property line ( see 2018 IRC R302.1 (1)
Electrical Service Inspection Passed 4/21/2021 04/21/2021
Gas Service Inspection - Residential Passed 4/21/2021 04/21/2021
All Rough Inspection - Residential Not Ready 4/21/2021 4/21/2021 04/21/2021
Miscellaneous Correction
Corrective Action Required
04/16/2021
House not ready for inspection this list was made without looking at plans or truss package list subject to change after trade make corrections complete below list and call for reinspect Fire blocking fireplace Seal penetration bottom plate master water closet Expose H2.5s deck Provide H2.5 or truss screws garage Provide 1 1/2 bearing girder truss at single car both ends Fire blocking at b vent laundry Fire stopping at beams Over bored joist above basement stairs Provide anchor bolts within 12" of plate breaks basement Support gas line per code Support DWV every 4' NE bed basement Seal upward penetrations throughout !!!!! Provide double joist hangers deck at fireplace Strap header at windows under deck Strap Corner at beam under deck Tighten anchor bolts throughout Tie top plate together above front door Support header covered deck ( remove plywood expose king studs) Nail corner studs per code Roof vents partially covered Fire blocking basement furr outs Comply with fire resistance rating for exterior wall/projections less than 5' from property line ( see 2018 IRC R302.1 (1) Provide lateral truss bracing per plans C4,C5,C6
Misc
Corrective Action Required
04/21/2021
- UPWARD & EXTERIOR PENETRATIONS STILL NOT SEALED - NOT READY Michael Harkins 04/21/2021 10:47 AM
All Rough Inspection - Residential Failed 5/5/2021 5/5/2021 05/05/2021
Miscellaneous Correction
Corrective Action Required
05/05/2021
Tape nail holes in moisture barrier at PFH Unable to verify braced wall nailing pattern throughout Fire blocking fireplace-seal all gaps Seal penetration bottom plate master water closet-seal penetration through floor Expose H2.5s deck Repair exterior sheathing and repair moisture barrier Seal gaps in exterior sheathing at fireplace and repair moisture barrier Provide 1 1/2 bearing girder truss at single car both ends-tie plates together with strap Fire blocking at b vent laundry-seal gaps Fire stopping at beams in finished walls Over bored joist above basement stairs Provide anchor bolts within 12" of plate breaks basement-tighten nuts Seal gaps and penetrations at fire blocking at top of fur out walls Seal penetrations in vertical fire blocking in fur out wall Tie exterior walls together at garage/ master closet- Provide engineered correction Missing truss screw master closet Strap header at windows under deck Strap Corner at beam under deck-both sides Tie top plate together above front door-neither side tied together at top plate per code Nail corner studs per code garage Fire blocking basement furr outs-Seal all gaps and penetrations Solid block to beam below at stud pack at corner of great room/dining and great room/ bed 1 for full bearing per plans Min (4) 2x4 studs at girder truss bearing per plan Comply with fire resistance rating for exterior wall/projections less than 5' from property line ( see 2018 IRC R302.1 (1) -Incomplete for length of protection at East wallet and west -Block corners East and west, fire caulk penetrations and gaps Provide lateral truss bracing per plans C4,C5,C6
Miscellaneous Correction
Corrective Action Required
05/05/2021
5-5-21 Not ready. Numerous items still not corrected from previous inspection.
Miscellaneous Correction
Informational
05/05/2021
- UPWARD & EXTERIOR PENETRATIONS STILL NOT SEALED - NOT READY Michael Harkins 04/21/2021 10:47 AM
All Rough Inspection - Residential Passed 5/13/2021 5/13/2021 05/13/2021
Miscellaneous Correction
Resolved
05/13/2021
Misc
Resolved
05/13/2021
Driveway Inspection Partial 5/21/2021 05/21/2021
Misc
Informational
05/21/2021
John M. Jackson Driveway 5/21/21 Forms and materials passed pre-inspection.
Driveway Inspection Passed 5/28/2021 5/28/2021 05/28/2021
Misc
Informational
05/21/2021
John M. Jackson Driveway 5/21/21 Forms and materials passed pre-inspection.
Misc
Informational
05/28/2021
Finished driveway meets LS and ADA specs. RP 5-28-21
Sidewalk Inspection Partial 7/19/2021 7/19/2021 07/19/2021
Misc
Informational
07/19/2021
Sidewalk was formed and rock was compacted. Also made them clean up in front of the house before passing the pre-pour. The forms appear to meed ADA standards.
Erosion Control Inspection Residential Failed 8/5/2021 08/05/2021
Misc
Corrective Action Required
02/08/2021
-Erosion control requires continuous maintenance. Repair damaged sections at curb and establish methods rear of lot within 48 hours -provide and maintain gravel filter -no further inspections until issues are resolved
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/05/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE UNTIL SOD COMPLETE _
Occupancy Inspection - Codes Residential Failed 8/5/2021 8/5/2021 08/05/2021
Miscellaneous Correction
Corrective Action Required
08/05/2021
Pay outstanding fees Sidewalk inspection still pending Provide final grade, sod & splash blocks Lower water meter lid to grade Submit back flow certification Provide access to test GFCI receptacle jacuzzi tub Install hood at cooktop Repair broken window dining room Complete fireplace deck A 4" sphere shall not pass through deck spindles Provide through bolts deck beam to post connection Complete treads deck stairway Sump discharge 36" from foundation Seal exterior penetrations irrigation at garage
Sidewalk Inspection Partial 8/12/2021 8/12/2021 08/12/2021
Misc
Informational
07/19/2021
Sidewalk was formed and rock was compacted. Also made them clean up in front of the house before passing the pre-pour. The forms appear to meed ADA standards.
Misc
Informational
08/12/2021
Forms were placed and aggregate was present and compacted. Water meter needs to be lowered. RP 8-12-21
Occupancy Inspection - Codes Residential Temporary C of O 8/13/2021 8/13/2021 08/13/2021
Miscellaneous Correction
Corrective Action Required
08/05/2021
Sidewalk inspection still pending Provide final grade, sod & splash blocks Lower water meter lid to grade Repair broken window dining room Provide through bolts deck beam to post connection Sump discharge 36" from foundation Seal exterior penetrations irrigation at garage
Occupancy Inspection - Codes Residential Failed 8/20/2021 8/20/2021 08/20/2021
Miscellaneous Correction
Corrective Action Required
08/13/2021
Sidewalk inspection still pending-NOT COMPLETED Provide final grade, sod- 6" fall in 10' required for drainage away from foundation, see Southwest Lower water meter lid to grade-14" to 18" from top of meter to top of can required AS WELL AS LID BEING AT GRADE Place tracer wire in box at grade Repair broken window dining room-NOT DONE
Sidewalk Inspection Passed 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/12/2021
Sidewalk was formed and rock was compacted. Also made them clean up in front of the house before passing the pre-pour. The forms appear to meed ADA standards.
Misc
Informational
08/12/2021
Forms were placed and aggregate was present and compacted. Water meter needs to be lowered. RP 8-12-21
Misc
Informational
08/20/2021
Finished sidewalk meets LS and ADA specs. RP 8-20-21
Occupancy Inspection - Codes Residential Failed 9/23/2021 9/23/2021 09/23/2021
Miscellaneous Correction
Corrective Action Required
08/20/2021
Lower water meter lid to grade-14" to 18" from top of meter to top of can required AS WELL AS LID BEING AT GRADE-NOT COMPLETE
Occupancy Inspection - Codes Residential Full C of O 10/7/2021 10/7/2021 10/07/2021
Miscellaneous Correction
Resolved
10/07/2021
Lower water meter lid to grade-14" to 18" from top of meter to top of can required AS WELL AS LID BEING AT GRADE-NOT COMPLETE
Documents & Images
Date Uploaded File Type Document Name
11/23/2020 Application Form W1 #10 - Permit App
11/24/2020 10 WOODSIDE RIDGE ROOF LAYOUT
11/24/2020 W1 #10 - Palermo - Mediterranean - Sheets- signed
11/24/2020 2523907 RF SEAL 11172020
11/24/2020 LOT 10 FINAL
11/30/2020 Drawing APPROVED ROOF TRUSS LAYOUT
11/30/2020 Specifications APPROVED TRUSS PACKAGE
12/10/2020 Plans APPROVED HOUSE PLAN
12/17/2020 Plot Plan APPROVED PLOT PLAN
12/17/2020 Receipt Receipt for transaction:2020-008075
12/17/2020 Letter DS Building Permit
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/08/2021 Letter INSPECTION SUMMARY
02/08/2021 Letter INSPECTION SUMMARY
02/19/2021 Letter INSPECTION SUMMARY
02/19/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
04/16/2021 Letter INSPECTION SUMMARY
04/19/2021 Approved Plans Approved Truss Revisons
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
04/21/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/21/2021 Letter INSPECTION SUMMARY
05/28/2021 Letter INSPECTION SUMMARY
07/19/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Letter INSPECTION SUMMARY
08/12/2021 Receipt Receipt for transaction:2021-006496
08/13/2021 Letter Codes Temporary Certificate of Occupancy
08/20/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
10/07/2021 Letter Codes Final Certificate of Occupancy
10/07/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home