Permit Application Status

PRRES20204231


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204231
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - UNCOVERED DECK
11/09/2020
12/16/2020
06/12/2021
07/21/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/18/2020 12/16/2020
Shannon McGuire
Plot Plan Review Approved 12/18/2020 12/16/2020
Kim Brennan
Basement opening elevations
Corrective Action Required
12/16/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 12/18/2020 12/16/2020
Kim Brennan
Plot Plan Review Rejected 11/12/2020 12/14/2020
Kim Brennan
Basement opening elevations
Corrective Action Required
12/14/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
Residential Plan Review Approved 11/12/2020 11/11/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,097.11 $1,097.11 Paid 12/16/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 12/16/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/16/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/16/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/16/2020
Outstanding Fees Amount Paid Owing Date Paid
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/8/2021 (11:30) 1/8/2021 01/08/2021
Misc
Informational
01/08/2021
- UFER SW FOUNDATION WALL REAR OF GARAGE -
Underslab Plumbing Inspection - Residential Failed 1/22/2021 1/22/2021 01/22/2021
Misc
Corrective Action Required
01/22/2021
- PROVIDE PERIMETER INTERIOR UNDERSLAB DRAIN TILE - - R506.2.5 / SEC 7-919
Underslab Plumbing Inspection - Residential Passed 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
Piers/Caissons Inspection - Residential Passed 2/26/2021 (1:00) 2/26/2021 02/26/2021
Misc
Corrective Action Required
02/26/2021
(2) 24 X 36 W/ (4) #4 BARS
Sewer Service Inspection - R Passed 3/11/2021 3/11/2021 03/11/2021
Water Service Inspection - R Passed 3/11/2021 (10:00) 3/11/2021 03/11/2021
Gas Service Inspection - Residential Failed 3/31/2021 03/31/2021
Misc
Corrective Action Required
03/31/2021
- COMPLETE GAS LINE CONNECTION TO FIREPLACE -
Electrical Service Inspection Passed 3/31/2021 03/31/2021
All Rough Inspection - Residential Failed 3/31/2021 3/31/2021 03/31/2021
Misc
Corrective Action Required
03/31/2021
Gas test fail Complete Connection to fireplace Electrical service pass :Call in above inspections with rough in : Provide lateral bracing truss D02 garage Address notched trusses garage/master closet ( engineer letter uploaded) Seal top plate penetration bed # 2 Seal bottom plate penetrations at kitchen sink Anchor bolts shall be in middle 1/3 of width of plate in garage Provide anchor bolts within 12" of plate break game room & behind patio door Tighten anchor bolts basement Provide (2) 2x10 joist game room /rec room per plan north end Fire block soffit game room Fire blocking top plate at furr out rec room Fire block top plate & soffit bed closet in basement south end
Gas Service Inspection - Residential Passed 4/6/2021 4/6/2021 04/06/2021
Misc
Resolved
04/06/2021
- COMPLETE GAS LINE CONNECTION TO FIREPLACE -
All Rough Inspection - Residential Failed 4/6/2021 4/6/2021 04/06/2021
Misc
Corrective Action Required
03/31/2021
Address notched trusses garage/master closet -(Use 3/4" Plywood or OSB per engineered correction, Master closet trusses not addressed at all) Anchor bolts shall be in middle 1/3 of width of plate in garage Fire block soffit line in game room Fire blocking top plate at furr out rec room-Seal gap middle of north wall Fire block soffit bed closet in basement south end
All Rough Inspection - Residential Failed 4/7/2021 4/7/2021 04/07/2021
Misc
Corrective Action Required
04/06/2021
**OK TO INSULATE-LEAVE BOTTOM PLATE IN GARAGE EXPOSED Address notched trusses garage/master closet -THE CORRECTIONS MADE AT THE GARAGE TRUSSES ARE NOT PER THE REPORT, THE TRUSSES NOTCHED IN THE MASTER CLOSET ARE NOT REPAIRED OR MENTIONED IN THE REPORT. PROVIDE ENGINEERED LETTER AND CORRECTION FOR TRUSSES IN THE MASTER CLOSET AND AND DOCUMENTATION THAT THE CORRECTIONS MADE TO THE GARAGE TRUSSES IS ADEQUATE -Anchor bolts shall be in middle 1/3 of width of plate in garage
All Rough Inspection - Residential Passed 4/13/2021 4/13/2021 04/13/2021
Misc
Resolved
04/13/2021
Driveway Inspection Partial 4/29/2021 4/29/2021 04/29/2021
Misc
Informational
04/29/2021
4-29-21 1:49pm The forms are set and the aggregate is compacted.
Driveway Inspection Passed 5/7/2021 5/7/2021 05/07/2021
Misc
Informational
04/29/2021
4-29-21 1:49pm The forms are set and the aggregate is compacted.
Misc
Informational
05/07/2021
Finished driveway meets LS specs. RP 5-7-21
Occupancy Inspection - Codes Residential Failed 6/25/2021 6/25/2021 06/25/2021
Miscellaneous Correction
Corrective Action Required
06/25/2021
Remove trash & construction debris Provide final grade & sod Seal exterior light fixtures at garage & open deck Seal top of meter can & A/C disconnect Remove dust covers smoke detectors Complete water heater b vent Through bolts deck beam Provide splash blocks Sump discharge 36" from foundation
Occupancy Inspection - Codes Residential Temporary C of O 7/14/2021 7/14/2021 07/14/2021
Miscellaneous Correction
Corrective Action Required
06/25/2021
Provide Through bolts deck beam
Occupancy Inspection - Codes Residential Full C of O 7/21/2021 7/21/2021 07/21/2021
Miscellaneous Correction
Resolved
07/21/2021
Documents & Images
Date Uploaded File Type Document Name
11/09/2020 Application Form Permit Application and license tax form
11/12/2020 Approved Plans Approved Truss Package
11/12/2020 Approved Plans Approved Truss Layout
12/11/2020 Approved Plans Approved Drawings
12/14/2020 Letter Codes Residential Plan Review
12/16/2020 Plot Plan Approved Plot Plan
12/16/2020 Receipt Receipt for transaction:2020-008062
12/16/2020 Letter DS Building Permit
01/08/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
02/26/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/11/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
04/02/2021 W2-4 Truss Repair
04/06/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/12/2021 Approved Plans Approved Truss Repair
04/13/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter INSPECTION SUMMARY
06/25/2021 Letter INSPECTION SUMMARY
07/02/2021 4 Woodside Ridge deck beam attachment letter
07/14/2021 Letter Codes Temporary Certificate of Occupancy
07/21/2021 Letter Field Certificate of Occupancy
07/21/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home