Permit Application Status

PRRES20204069


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20204069
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINIHED BASEMENT
10/30/2020
11/09/2020
05/02/2021
09/28/2021
Locations
Contacts
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
JPROBERTS23@HOTMAIL.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/09/2020 11/09/2020
Dylan Eppert
North arrow and scale
Corrective Action Required
11/05/2020

The plot plan must be submitted on either (1) 81/2” x 11”, (2) 81/2”x 14”, or (3) 11” x 17” paper. All information on the plot plan must be drawn to scale. Scale must be 1” = 10’, 20’, or 30’; smaller scales that are multiples of the preceding scales may be used if necessary to represent large sites. All information on the plot plan must be clearly legible.) DIDN'T APPEAR TO BE TO SCALE ON THE 1"=30' OR THE 1"=20' DRAWING.
City infrustructure
Corrective Action Required
11/05/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING MANHOLE FOR STORM.
Spot elevations
Corrective Action Required
11/05/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ONCE PLOT PLAN IS TO SCALE I CAN CHECK THE SLOPE TO ENSURE THE 2% MINIMUM IS MET.
Planning Review (RES) Approved 11/05/2020 11/09/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
11/03/2020

EXTERIOR MATERIALS. Label the horizontal siding material on the elevations.
Residential Plan Review Approved 11/09/2020 11/05/2020
Dylan Eppert
Planning Review (RES) Rejected 11/03/2020 11/03/2020
Hector Soto Jr.
Miscellaneous Correction
Corrective Action Required
11/03/2020

EXTERIOR MATERIALS. Label the horizontal siding material on the elevations.
Plot Plan Review Rejected 11/03/2020 11/03/2020
Dylan Eppert
North arrow and scale
Corrective Action Required
11/03/2020

The plot plan must be submitted on either (1) 81/2” x 11”, (2) 81/2”x 14”, or (3) 11” x 17” paper. All information on the plot plan must be drawn to scale. Scale must be 1” = 10’, 20’, or 30’; smaller scales that are multiples of the preceding scales may be used if necessary to represent large sites. All information on the plot plan must be clearly legible.) DIDN'T APPEAR TO BE TO SCALE ON THE 1"=30' OR THE 1"=20' DRAWING.
City infrustructure
Corrective Action Required
11/03/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. MISSING MANHOLE FOR STORM.
Spot elevations
Corrective Action Required
11/03/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ONCE PLOT PLAN IS TO SCALE I CAN CHECK THE SLOPE TO ENSURE THE 2% MINIMUM IS MET.
Residential Plan Review Approved 11/03/2020 11/03/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/04/2020
$1,077.12
New Longview Road and Bridge Escrow $1,077.12 $1,077.12 Paid 11/09/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 11/09/2020
8331507-Sewer Connection Fee $690.00 $690.00 Paid 11/09/2020
Water Meter Fee $455.54 $455.54 Paid 11/09/2020
Valuation Fee New Single Family $1,933.29 $1,933.29 Paid 11/09/2020
Right of Way Permit Fee $80.00 $80.00 Paid 11/09/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/1/2020 (2:00) 12/1/2020 12/01/2020
Underslab Plumbing Inspection - Residential Failed 12/30/2020 12/30/2020 12/29/2020
Misc
Corrective Action Required
12/29/2020
Connect interior underslab tile to sump pit
Underslab Plumbing Inspection - Residential Passed 12/31/2020 12/31/2020 12/30/2020
Misc
Resolved
12/30/2020
Connect interior underslab tile to sump pit
Erosion Control Inspection Residential Failed 01/08/2021
Misc
Corrective Action Required
01/08/2021
Immediate Street clean up required. No further inspections until issue is resolved
Miscellaneous Inspection Failed 01/08/2021
Misc
Corrective Action Required
01/08/2021
Post site address
Miscellaneous Inspection Passed 02/04/2021
Misc
Resolved
02/04/2021
Post site address
Erosion Control Inspection Residential Failed 02/04/2021
Misc
Corrective Action Required
01/08/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -immediate street cleanup required -no further inspections until issues are resolved
Sewer Service Inspection - R Passed 4/9/2021 (10:00) 4/9/2021 04/09/2021
Water Service Inspection - R Passed 4/12/2021 (8:30) 4/12/2021 04/12/2021
All Rough Inspection - Residential Failed 4/22/2021 4/22/2021 04/22/2021
Misc
Corrective Action Required
04/22/2021
-Protect nonmetallic Conductors minimum 6 inches AFF At floor penetrations -Nail joist hangers -Make up all outlet boxes and mechanically fastened spliced equipment grounding conductors -Replace full depth solid blocking removed or damaged by other trades -Submit suspended slab third-party inspection report -Anchor steel columns in basement -Complete electrical installation -Provide joist hangers first floor framing at furnace equipment -Full depth solid blocking where joist run parallel with foundation per plan -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -provide engineered solution for vertically drilled LVL at portal opening -Tighten anchor bolts garage Provide anchor bolt within 12" of plate break garage -Expose portal framing at garage ( holddowns, nailing pattern -Provide vertical support dwv 2" or smaller at midpoint -Seal pex at fireplace pan off -Support pex at fireplace -Provide 1" clearance fireplace vent -Seal low volt penetrations lv rm -Provide joist hangers in office -Strap top plate dwv office -Provide metallic tape exhaust fan -Address rafters landing on blocks master closet & master bedroom -Plans show double LVLs in loft -Bed #5 solid block / fire block closet at top plate -Seal upward penetration bath between bed 3 & 4 -2x8 purlin with 2 x 6 t brace detail #2 roof plan
Electrical Service Inspection Passed 5/6/2021 5/6/2021 04/22/2021
Gas Service Inspection - Residential Passed 5/6/2021 5/6/2021 04/22/2021
Erosion Control Inspection Residential Failed 04/22/2021
Misc
Corrective Action Required
02/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 5/4/2021 5/4/2021 05/04/2021
Misc
Corrective Action Required
04/22/2021
-Make up all outlet boxes and mechanically fasten spliced equipment grounding conductors -Replace full depth solid blocking over beams removed or damaged by other trades -Submit suspended slab third-party inspection report -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -Continue 3” grid at portal frame -Seal low volt penetrations lv rm -Seal upward penetration bath between bed 3 & 4
Erosion Control Inspection Residential Failed 05/04/2021
Misc
Corrective Action Required
04/22/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours -no further inspections until issues are resolved
All Rough Inspection - Residential Failed 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
05/04/2021
-mechanically fasten all spliced equipment grounding conductors Ok to insulate
All Rough Inspection - Residential Passed 5/6/2021 5/6/2021 05/06/2021
Misc
Resolved
05/06/2021
-mechanically fasten all spliced equipment grounding conductors Ok to insulate
Erosion Control Inspection Residential Passed 05/06/2021
Misc
Resolved
05/06/2021
Sidewalk Inspection Partial 8/20/2021 8/20/2021 08/20/2021
Misc
Informational
08/20/2021
Forms were placed and aggregate was present and compacted. The storm manhole for the junction box is located in the sidewalk, but the sanitary manhole is located outside of the sidewalk. RP 8-20-21
Sidewalk Inspection Failed 8/27/2021 8/27/2021 08/27/2021
Misc
Informational
08/20/2021
Forms were placed and aggregate was present and compacted. The storm manhole for the junction box is located in the sidewalk, but the sanitary manhole is located outside of the sidewalk. RP 8-20-21
Misc
Corrective Action Required
08/27/2021
Need to remove and replace broken panel. RP 8-27-21
Occupancy Inspection - Codes Residential Failed 9/3/2021 9/3/2021 09/03/2021
Misc
Corrective Action Required
09/03/2021
*9-3-21 INSPECITON DENIED -No address -No erosion control -Provide erosion control at perimeter of lot and maintain until sod is in place. Clean mud and debris from sidewalk, street and storm inlet. Protect street and sidewalks. No further inspections will be performed until in compliance
Erosion Control Inspection Residential Failed 09/03/2021
Miscellaneous Correction
Corrective Action Required
09/03/2021
*9-3-21 INSPECITON DENIED -No address -No erosion control -Provide erosion control at perimeter of lot and maintain until sod is in place. Clean mud and debris from sidewalk, street and storm inlet. Protect street and sidewalks. No further inspections will be performed until in compliance
Occupancy Inspection - Codes Residential Failed 9/7/2021 9/7/2021 09/07/2021
Misc
Corrective Action Required
09/03/2021
-Final sidewalk and driveway inspections required -obtain lawn irrigation system permit -Complete sod and landscaping install -Guardrail at front porch, more than 30” from grade -GFCI protection required at kitchen countertop receptacle right of fridge -security screws, (2) 3” screws at each hinge and strike plate at exterior doors, see kitchen ext door, back door at garage -Garage west wall duplex receptacle must be GFCI protected -Handrail required at ext door garage side, 4 rises
Occupancy Inspection - Codes Residential Temporary C of O 9/8/2021 9/8/2021 09/08/2021
Misc
Corrective Action Required
09/07/2021
-Final sidewalk and driveway inspections required -obtain lawn irrigation system permit -Complete sod and landscaping install -Guardrail at front porch, more than 30” from grade -Handrail required at ext door garage side, 4 rises **OK FOR TCO - TCO EXPIRES 10/8/21**
Occupancy Inspection - Codes Residential Failed 9/17/2021 9/17/2021 09/17/2021
Misc
Corrective Action Required
09/08/2021
-Final sidewalk and driveway inspections required -not approved -obtain lawn irrigation system permit - not paid for -Guardrail at front porch, more than 30” from grade , bring grade up to less than 30" at 36" out from porch, **OK FOR TCO - TCO EXPIRES 10/8/21**
Erosion Control Inspection Residential Passed 09/28/2021
Miscellaneous Correction
Resolved
09/28/2021
*9-3-21 INSPECITON DENIED -No address -No erosion control -Provide erosion control at perimeter of lot and maintain until sod is in place. Clean mud and debris from sidewalk, street and storm inlet. Protect street and sidewalks. No further inspections will be performed until in compliance
Occupancy Inspection - Codes Residential Temporary C of O 9/28/2021 9/28/2021 09/28/2021
Misc
Corrective Action Required
09/17/2021
-Final sidewalk and driveway inspections required -not approved **OK FOR TCO
Sidewalk Inspection Passed 9/28/2021 9/28/2021 09/28/2021
Misc
Informational
08/27/2021
Forms were placed and aggregate was present and compacted. The storm manhole for the junction box is located in the sidewalk, but the sanitary manhole is located outside of the sidewalk. RP 8-20-21
Misc
Corrective Action Required
08/27/2021
Need to remove and replace broken panel. RP 8-27-21
Misc
Informational
09/28/2021
Broken panel has been replaced. RP 9-28-21
Occupancy Inspection - Codes Residential Full C of O 9/28/2021 09/28/2021
Misc
Resolved
09/28/2021
-Final sidewalk and driveway inspections required -not approved **OK FOR TCO
Documents & Images
Date Uploaded File Type Document Name
10/30/2020 Application Form 3222 SW Pergola Park Permit Application
10/30/2020 COMPLETE SET LANDROCK - MCNUTT - GOOD - MO
10/30/2020 LOT 113 PERGOLA PARK FINAL
10/30/2020 3222 Pergola Park Excise Tax Application
11/03/2020 Plans APPROVED HOUSE PLANS
11/03/2020 Letter Codes Residential Plan Review
11/05/2020 APPROVED PLOT PLAN
11/09/2020 Receipt Receipt for transaction:2020-007466
11/09/2020 Letter DS Building Permit
12/01/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/30/2020 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
04/09/2021 Letter INSPECTION SUMMARY
04/12/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
05/03/2021 2021-05-03 Letter - Rough In Inspection
05/03/2021 A4- ROOF PLAN-3
05/03/2021 A2- FIRST FLOOR PLAN-17
05/04/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/03/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/08/2021 Letter Codes Temporary Certificate of Occupancy
09/16/2021 3222 SW PERGOLA PARK DR - IRRIGATION
09/17/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter Codes Temporary Certificate of Occupancy
09/28/2021 Letter INSPECTION SUMMARY
09/28/2021 Letter Field Certificate of Occupancy
09/28/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home