Permit Application Status

PRRES20203786


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203786
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT
10/16/2020
01/14/2021
04/25/2021
01/18/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
YANCIK@SBCGLOBAL.NET  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/05/2020 11/03/2020
Dylan Eppert
Residential Plan Review Approved 11/05/2020 11/03/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
11/03/2020

HOUSE IS FLIPPED FROM WHAT IS PROPOSED ON THE PLOT PLAN. PLANS MUST MATCH THE PLOT PLAN. PLEASE REVISE.
Plot Plan Review Approved 10/26/2020 10/28/2020
Dylan Eppert
Spot elevations
Corrective Action Required
10/27/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. THE SOUTH SIDE DOESN'T HAVE A MINIMUM 2% SLOPE.
Residential Plan Review Rejected 10/26/2020 10/27/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
10/27/2020

HOUSE IS FLIPPED FROM WHAT IS PROPOSED ON THE PLOT PLAN. PLANS MUST MATCH THE PLOT PLAN. PLEASE REVISE.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $952.82 $952.82 Paid 01/13/2021
8331507-Sewer Connection Fee $330.00 $330.00 Paid 01/13/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 01/13/2021
Water Meter Fee $455.54 $455.54 Paid 01/13/2021
Right of Way Permit Fee $80.00 $80.00 Paid 01/13/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/13/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 2/1/2021 2/1/2021 02/01/2021
Miscellaneous Correction
Corrective Action Required
02/01/2021
-Post address -Backfill around foundation wall and provide access for inspection
Underslab Plumbing Inspection - Residential Passed 2/3/2021 02/03/2021
Miscellaneous Correction
Resolved
02/03/2021
-Post address -Backfill around foundation wall and provide access for inspection
Erosion Control Inspection Residential Failed 02/03/2021
Misc
Corrective Action Required
02/03/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -provide and maintain gravel filter -no further inspections until issues are resolved
Sewer Service Inspection - R Passed 3/3/2021 (8:00) 3/3/2021 03/03/2021
Water Service Inspection - R Passed 3/4/2021 (1:00) 3/4/2021 03/04/2021
All Rough Inspection - Residential Partial 3/30/2021 3/30/2021 03/30/2021
Misc
Informational
03/30/2021
portal frame approved
Electrical Service Inspection Failed 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
05/05/2021
SE Conductors require a minimum bending radius five times the diameter of the conductor
Gas Service Inspection - Residential Passed 5/5/2021 5/5/2021 05/05/2021
All Rough Inspection - Residential Failed 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
05/05/2021
-Make up all outlet boxes -Ground metallic outlet boxes -Address rafters bearing on blocks throughout -Secure vertical NM Conductors a minimum of 1.25” from face of stud throughout -Nail plate protection at Conductor stud, top/bottom plate Penetrations with Penetration is less than 1.25 from the face of the framing member, throughout -Fireblock top and bottom plate Penetrations with approved materials, not caulking, laundry -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Fireblock Penetration in subfloor, gas tubing to fireplace -Midpoint strap for all vertical 2 inch and smaller DWV -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side of straps. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -Fasten headers to King studs per code -Fireblock top plate Penetrations, pantry -Top plate splices to offset minimum 24 inches -Strap noncontinuous studs at gable wall, bed two -Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. 5 locations south foundation wall, 1 location in hall at bed 3 entrance, bed 3 at smoke alarm, two locations bed three closet, Three locations above bed three window, 2 locations above rec room -Grounding electrode conductor connection to concrete encased electrode is required to remain accessible -Secure framing at basement storage entrance -Support 2x4’s laid flat in soffit to floor framing above, where 2x4 exceeds 4’ -Unable to locate water heater circuit -Repair/replace full depth solid blocking over beams removed/damaged by other trades -Seal Penetration in Joist where cavity is used as return air Plenum, outside of bedroom three -Properly fireblock vertical to horizontal at soffit to wall connections -SE Conductors require minimum bending radius of five times the diameter of the conductor -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Install basement windows -Water system bleed and shutoff valve to remain accessible -Where opposing rafters meet the ridge they shall not offset more than 1 inch -Roof support per plan, master bedroom, see roof framing page -Minimum quarter inch of conductor outer sheating in boxes -More than 2 NM cables containing two or more current carrying conductors are installed in the same opening that is to be sealed with sealing foam the allowable of each conductor ampacity shall be adjusted per table 3705.3
All Rough Inspection - Residential Failed 5/10/2021 5/10/2021 05/10/2021
Misc
Corrective Action Required
05/05/2021
-Address rafters bearing on blocks throughout. Comply with section R802.5.2 or provide engineered solution for repair -Secure vertical NM Conductors a minimum of 1.25” from face of stud throughout or provide physical protection of conductors. See table E3802.1 -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side of straps. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1. Living room/toilet room wall -Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. 5 locations south foundation wall, 1 location in hall at bed 3 entrance, bed 3 at smoke alarm, two locations bed three closet, Three locations above bed three window, 2 locations above rec room. Comply with section 502.8.1 or provide engineered solution for repair -Install basement windows -Water system bleed and shutoff valve to remain accessible -More than two NM cables containing two or more current carrying conductors are installed in the same opening that is to be sealed with sealing foam, the allowable of each conductor ampacity shall be adjusted per table 3705.3, penetrations in top/bottom plates. Address this issue or derate conductor ampacity per table. See E3705.4.4
Electrical Service Inspection Passed 5/10/2021 5/10/2021 05/10/2021
Misc
Resolved
05/10/2021
SE Conductors require a minimum bending radius five times the diameter of the conductor
Footing Inspection - Residential Passed 05/12/2021
All Rough Inspection - Residential Failed 5/13/2021 5/13/2021 05/13/2021
Misc
Corrective Action Required
05/10/2021
-Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. 5 locations south foundation wall, 1 location in hall at bed 3 entrance, bed 3 at smoke alarm, two locations bed three closet, Three locations above bed three window, 2 locations above rec room. Comply with section 502.8.1 or provide engineered solution for repair Ok to insulate
Erosion Control Inspection Residential Failed 05/13/2021
Misc
Corrective Action Required
02/03/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -no further inspections until issues are resolved
All Rough Inspection - Residential Passed 5/17/2021 05/17/2021
Misc
Resolved
05/17/2021
-Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. 5 locations south foundation wall, 1 location in hall at bed 3 entrance, bed 3 at smoke alarm, two locations bed three closet, Three locations above bed three window, 2 locations above rec room. Comply with section 502.8.1 or provide engineered solution for repair Ok to insulate
Driveway Inspection Partial 6/14/2021 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
6/14/21 9:00AM- Drive approach has been compacted and is 6in deep, informed the crew to carry 1.5% for the sidewalk, to use KCMMB mix and to place expansion joint on the curb line.
Sidewalk Inspection Partial 6/14/2021 6/14/2021 06/14/2021
Misc
Informational
06/14/2021
6/14/21 9:00AM- Sidewalk is 4in in depth, 5ft off the back of the curb, 5ft wide and is carrying 1.5% or less. Sidewalk and drive are good to pour.
Driveway Inspection Passed 6/18/2021 6/18/2021 06/18/2021
Misc
Informational
06/14/2021
6/14/21 9:00AM- Drive approach has been compacted and is 6in deep, informed the crew to carry 1.5% for the sidewalk, to use KCMMB mix and to place expansion joint on the curb line.
Misc
Informational
06/18/2021
6/18/21 8:20- Driveway is carrying the correct % of slope for the sidewalk, expansion joints placed on the curb and easement line, and correct cure was placed.
Sidewalk Inspection Passed 6/18/2021 6/18/2021 06/18/2021
Misc
Informational
06/14/2021
6/14/21 9:00AM- Sidewalk is 4in in depth, 5ft off the back of the curb, 5ft wide and is carrying 1.5% or less. Sidewalk and drive are good to pour.
Misc
Informational
06/18/2021
6/18/21 8:20- Sidewalk is carrying the correct % throughout it and has the correct cure placed.
Occupancy Inspection - Codes Residential Failed 8/24/2021 8/24/2021 08/24/2021
Misc
Corrective Action Required
08/24/2021
-Provide erosion control at perimeter before any further inspections -As graded plot plan required -Final grade and sod -Provide splash blocks and sump discharge extension -Obtain lawn sprinkler permit and backflow certification -Provide missing exterior lighting- address illumination required at front and flood light at back -Install light fixture or cover plate at kitchen island -Complete plumbing at kitchen sink -Complete electrical at hot water heater -GFCI receptacle in basement bath won't reset -Provide lockouts at range and cooktop breakers -Seal exterior penetration at inter system bonding terminal -Secure AC whip at disconnect -Ensure sewer tracer wire and port are accessible and located at grade level
Occupancy Inspection - Codes Residential Temporary C of O 8/26/2021 8/26/2021 08/26/2021
Misc
Corrective Action Required
08/24/2021
TCO until 9-23-21 -Maintain erosion control at perimeter until sod is installed -As graded plot plan required -Final grade and sod -Obtain lawn sprinkler permit and backflow certification -Ensure sewer tracer wire and port are accessible and located at grade level
Erosion Control Inspection Residential Passed 07/22/2022
Misc
Resolved
07/22/2022
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -no further inspections until issues are resolved
Occupancy Inspection - Codes Residential Failed 7/22/2022 7/22/2022 07/22/2022
Misc
Corrective Action Required
08/26/2021
TCO until 9-23-21 -As graded plot plan required not on file, as of 07/22/2022 10:46 AM - TCO EXPIRED SUBMIT EXTENSION LETTER
Plot Plan Inspection Passed 1/18/2023 01/18/2023
Occupancy Inspection - Codes Residential Full C of O 1/18/2023 1/18/2023 01/18/2023
Misc
Resolved
01/18/2023
Documents & Images
Date Uploaded File Type Document Name
10/16/2020 Application Form SKM_C36820101613350
10/22/2020 winterset lot 1436 plot plan
10/22/2020 winterset lot 1436 digital plans
10/27/2020 Letter Codes Residential Plan Review
10/28/2020 Plot Plan APPROVED PLOT PLAN
11/03/2020 Plans APPROVED HOUSE PLAN
01/13/2021 Receipt Receipt for transaction:2021-000204
01/14/2021 Letter DS Building Permit
01/21/2021 Garys Fndn 153 NW Carson Dr Lee's Summit Mo 3rd Party Footing Inspection Report 1-20-21
02/01/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter Codes Residential Plan Review
02/03/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/12/2021 LOT 1436 ROOF REPORT
05/13/2021 Letter INSPECTION SUMMARY
05/13/2021 Letter INSPECTION SUMMARY
05/16/2021 153 NW Carson Dr LSMO Lot 1436 Winterset Framing Issues Report 5-14-21 (1)
05/17/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/14/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
08/24/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter Codes Temporary Certificate of Occupancy
07/22/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
12/09/2022 Letter Codes 140 Day Letter
01/17/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
01/18/2023 Letter INSPECTION SUMMARY
01/18/2023 Letter Codes Final Certificate of Occupancy
01/18/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home