Permit Application Status

PRRES20203581


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203581
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - PARTIAL FINISHED BASEMENT
10/07/2020
10/14/2020
07/13/2022
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
WOODBROTHERSINC@GMAIL.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
BMW ELECTRIC CO, Address:1238 W 31ST, Phone:(816) 289-3474  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/09/2020 10/13/2020
Dylan Eppert
Misc
Corrective Action Required
10/09/2020

label covered deck
Basement egress
Corrective Action Required
10/09/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. please provide lag for the walkout .
Planning Review (RES) Approved 10/09/2020 10/09/2020
Dylan Eppert
Residential Plan Review Approved 10/09/2020 10/09/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,061.83 $1,061.83 Paid 10/14/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 10/14/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/14/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/14/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/14/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/14/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/20/2020 11/20/2020
Underslab Plumbing Inspection - Residential Passed 1/13/2021 1/13/2021 01/13/2021
Sewer Service Inspection - R Passed 1/29/2021 (11:30) 1/29/2021 01/29/2021
Water Service Inspection - R Passed 2/1/2021 (1:00) 2/1/2021 02/01/2021
Piers/Caissons Inspection - Residential Partial 3/3/2021 (1:15) 3/3/2021 03/03/2021
Misc
Corrective Action Required
03/03/2021
THE NORTH PIER IS FULL OF WATER. PUMP OUT WATER AND REMOVE CAVED-IN DIRT. OK TO POUR THE OTHER PIERS
Gas Service Inspection - Residential Failed 7/2/2021 7/2/2021 07/02/2021
Misc
Corrective Action Required
07/02/2021
-Complete gas piping to fireplace
Electrical Service Inspection Passed 7/2/2021 7/2/2021 07/02/2021
Misc
Corrective Action Required
07/02/2021
All Rough Inspection - Residential Failed 7/2/2021 7/2/2021 07/02/2021
Misc
Corrective Action Required
07/02/2021
-Maintain gravel filter, silt fence, and clean mud and debris from street before any further inspections -Fur out garage walls for R13 insulation at hvac -Strap top plate overlapping less than 2’ at north garage wall by beam -Seal top plate penetration garage by hvac -Address sheathing where staples are used in place of nails -Provide joist hanger at laundry -provide midpoint strap on all dwv 2” or smaller -Seal bottom plate penetration in master bed and master bath -Fix moisture barrier in corner of master bed not installed properly -Replace blocks in corner with full height stud at breakfast area -Provide (2) king studs at header in breakfast -Repair moisture barrier and land electrical in box at covered deck -Seal plate penetration at covered deck outlet -Fire block ceiling line at sides of fireplace -Complete gas to fireplace -Provide bonding screws and jumpers at metallic floor boxes -Seal plate penetration ls top and bottom in office -Provide joist hangers at stair landing joists over 4’ -Insulate and block cantilevers in basement -Provide (3) studs in corners of foundation walls -Complete electrical in basement -Fireblock top of stairwell wall and beam pocket -Security blocking at basement doors -Address missing 3” and 3.5” sch 40 columns at stairwell -Anchor steel columns to floor -FB tub trap office bath -Nail all exterior sheathing per code -Complete deck framing
All Rough Inspection - Residential Failed 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/02/2021
*2nd inspection -Strap top plate overlapping less than 2’ at north garage wall by beam -Seal top plate penetration garage by hvac -Address sheathing where staples are used in place of nails -Fire block ceiling line at sides of fireplace -Provide joist hangers at stair landing joists over 4’-Install missing nails -block cantilevers in basement -Provide (3) studs in corners of foundation walls -Complete electrical in basement -Address missing 3” and 3.5” sch 40 columns at stairwell -Nail all exterior sheathing per code -Complete deck framing
Gas Service Inspection - Residential Passed 7/14/2021 7/14/2021 07/14/2021
Misc
Resolved
07/14/2021
-Complete gas piping to fireplace
All Rough Inspection - Residential Failed 7/21/2021 7/21/2021 07/21/2021
Misc
Corrective Action Required
07/14/2021
-Strap top plate overlapping less than 2’ at north garage wall by beam **not done
Driveway Inspection Partial 8/24/2021 8/24/2021 08/26/2021
Misc
Informational
08/26/2021
On 8/24/2021 I conducted a subgrade inspection and subgrade passed inspection
Driveway Inspection Passed 9/1/2021 9/1/2021 09/23/2021
Misc
Informational
08/26/2021
On 8/24/2021 I conducted a subgrade inspection and subgrade passed inspection
All Rough Inspection - Residential Passed 11/29/2021
Misc
Resolved
11/29/2021
-Strap top plate overlapping less than 2’ at north garage wall by beam **not done
Piers/Caissons Inspection - Residential Passed 11/29/2021
Misc
Resolved
11/29/2021
THE NORTH PIER IS FULL OF WATER. PUMP OUT WATER AND REMOVE CAVED-IN DIRT. OK TO POUR THE OTHER PIERS
Occupancy Inspection - Codes Residential Temporary C of O 11/29/2021 11/30/2021 11/30/2021
Misc
Corrective Action Required
11/30/2021
-Final grade, sod, downspout and sump pump extensions -Garage door not self closing -Fb opening below garage boxed out walls -Provide fall protection devices for rear dining windows per IRC
Occupancy Inspection - Codes Residential Full C of O 7/13/2022 7/13/2022 07/13/2022
Misc
Resolved
07/13/2022
-Final grade, sod, downspout and sump pump extensions -Garage door not self closing -Fb opening below garage boxed out walls -Provide fall protection devices for rear dining windows per IRC
Documents & Images
Date Uploaded File Type Document Name
10/07/2020 Signed Building permit application
10/07/2020 Signed Excise tax application
10/07/2020 LOT 52 FINAL plot plan
10/07/2020 DW Revised Permit Plan Revised Willow Lot 52 Trails of Park Ridge 4068 NE Timberlake Ct 10_1_20
10/09/2020 Plans APPROVED HOUSE PLANS
10/09/2020 Letter Codes Residential Plan Review
10/14/2020 Receipt Receipt for transaction:2020-006930
10/14/2020 Letter DS Building Permit
11/20/2020 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/01/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/02/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
09/03/2021 Plot Plan APPROVED PLOT PLAN
09/23/2021 Letter INSPECTION SUMMARY
09/23/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
11/29/2021 Letter INSPECTION SUMMARY
11/30/2021 Letter Codes Temporary Certificate of Occupancy
07/13/2022 Letter Field Certificate of Occupancy
07/13/2022 Letter Codes Final Certificate of Occupancy
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:
Browse..





    Portal Home