Summary
PRRES20203428
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
09/30/2020
10/02/2020
04/09/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/06/2020 10/02/2020
Kim Brennan
Residential Plan Review Approved 10/06/2020 10/02/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,156.72 $1,156.72 Paid 10/02/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/02/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/02/2020
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 10/02/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 10/02/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/02/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/02/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 04/07/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/16/2020 10/16/2020
Underslab Plumbing Inspection - Residential Passed 11/4/2020 11/4/2020 11/04/2020
Piers/Caissons Inspection - Residential Passed 11/20/2020 11/20/2020
Sewer Service Inspection - R Passed 12/15/2020 (10:30) 12/15/2020 12/15/2020
Water Service Inspection - R Partial 12/15/2020 12/15/2020 12/15/2020
Misc
Informational
12/15/2020
- PARTIAL INSPECTION ON PEX FROM MID POINT IN YARD TO ENTRANCE AT HOUSE. OK TO COVER PORTION INSPECTED
Water Service Inspection - R Passed 12/16/2020 (8:30) 12/16/2020 12/16/2020
Misc
Resolved
12/16/2020
- PARTIAL INSPECTION ON PEX FROM MID POINT IN YARD TO ENTRANCE AT HOUSE. OK TO COVER PORTION INSPECTED
Gas Service Inspection - Residential Passed 1/8/2021 1/8/2021 01/08/2021
Electrical Service Inspection Passed 1/8/2021 1/8/2021 01/08/2021
All Rough Inspection - Residential Failed 1/8/2021 1/8/2021 01/08/2021
Miscellaneous Correction
Corrective Action Required
01/08/2021
**THIS LIST MAY BE INCOMPLETE** -NO ACCESS TO EAST WALL AT BREAKFAST AND WEST WALL IN OFFICE -UNABLE TO VERIFY NAILING PATTERN AND HOLD DOWNS AT GARAGE PORTAL FRAME -UNABLE TO VERIFY INSTILLATION OF H2.5 AT FRONT PORCH -INSTALL ALL FLASHING AND WINDOWS -Complete nailing pattern at exterior sheathing per plan -Provide lag bolts at deck ledger -Provide angel clip to end joist/ ledger connection -Provide (2) bolts per post/ joist connection at deck -Anchor bolts in garage to be in middle third of plate throughout -Missing H2.5 at B3 truss above corner of single car bay -Provide truss hangers at trusses B3 and B4 in garage per plan -Fireblock soffit line in garage -Fireblock duct chase in garage to prevent vertical to horizontal fire spread -Connect all flat 2x4 framing at furdowns to ceiling joists so that span is no greater than 36” -Provide midpoint strap on all DWV 2” and smaller -Provide BOCCA plates at top and bottom wall plates at all DWV and PEX at all locations less than 1 1.25” from face of stud throughout -Seal penetrations in dead space at great room -Seal gaps in fireblocking at fireplace -Provide structural strap at all exterior walls where top plate is bored more than 50% -Provide stud shoes on all studs bored greater than 40% in exterior walls -Nail LVL beam to adjacent stud In pantry -Complete electrical in breakfast -Provide LIB at all locations -Provide EC2 all locations -Add 2x4 stud at bearing wall openings at garage entry and refrigerator alcove per plans -Missing (3) 2x10 beam at office -Missing (3) 2x4 studs in NW office corner for beam bearing -Nail double girder truss H4 per code -Seal plate penetrations in bed 1 -Seal nm penetrations in fireblocking at duct chase in laundry -Support DWV 4” OC in attic per code -Provide proper fall at DWV in attic per code -Provide lateral truss bracing at trusses E4, E7, E8, E9 per plans -Seal all plate penetrations in basement -Seal gaps in fireblocking at dead space by basement bathroom -Provide vertical fireblocking at max 10’ OC in east fur out wall basement -Seal gaps in vertical fireblocking at north and south walls basement -Fireblock beam webs in finished walls basement -Seal stud penetrations in return air space at mechanical room basement -Ensure access to cleanout under stairs in basement -Provide hangers on double 2x10 in rec room and bathroom basement -Complete DWV drain in closet at basement
All Rough Inspection - Residential Failed 1/14/2021 1/14/2021 01/14/2021
Miscellaneous Correction
Corrective Action Required
01/08/2021
-UNABLE TO VERIFY INSTILLATION OF H2.5 AT FRONT PORCH -Install flashing and windows basement -Provide angel clip to end joist/ ledger connection -Provide (2) bolts per post/ joist connection at deck -Connect all flat 2x4 framing at furdowns to ceiling joists so that span is no greater than 36”-see basement furred down -Provide BOCCA plates at top and bottom wall plates at all DWV and PEX at all locations less than 1 1.25” from face of stud throughout -see laundry room top plate 2nd floor -Provide LIB at all locations -Provide EC2 all locations -Missing (3) 2x10 beam at office -Seal plate penetrations in bed 1 -Seal gaps in fireblocking at dead space by basement bathroom -Provide vertical fireblocking at max 10’ OC in east fur out wall basement -Seal gaps in vertical fireblocking at north and south walls basement -Seal stud penetrations in return air space at mechanical room basement -Provide hangers on double 2x10 in rec room and bathroom basement
All Rough Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Miscellaneous Correction
Corrective Action Required
01/14/2021
-UNABLE TO VERIFY INSTILLATION OF H2.5 AT FRONT PORCH -Install flashing and windows basement -Provide angel clip to end joist/ ledger connection -Provide (2) bolts per post/ joist connection at deck -Connect all flat 2x4 framing at furdowns to ceiling joists so that span is no greater than 36”-see basement furred down -Provide LIB at all locations-Second floor -Connect EC2 strap to beam-should connect top floor to bottom floor -Missing (3) 2x10 beam at office -Provide vertical fireblocking at max 10’ OC in east fur out wall basement -Provide hangers on double 2x10 in rec room and bathroom basement
All Rough Inspection - Residential Failed 1/25/2021 1/25/2021 01/25/2021
Miscellaneous Correction
Corrective Action Required
01/19/2021
-Install flashing and windows basement **OK TO INSULATE**
Driveway Inspection Partial 2/3/2021 (P.M.) 2/3/2021 02/04/2021
Misc
Informational
02/04/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 2/10/2021 2/10/2021 02/22/2021
Misc
Informational
02/04/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Passed 03/24/2021
Miscellaneous Correction
Resolved
03/24/2021
-Install flashing and windows basement **OK TO INSULATE**
Occupancy Inspection - Codes Residential Failed 3/24/2021 3/24/2021 03/24/2021
Misc
Corrective Action Required
03/24/2021
-Sidewalk required -Final grade and sod -Gutters, downspouts, splash blocks and sump pump discharge extension required -seal all penetrations in siding, seal along top of AC disconnect and meter can -Guardrail required at front porch, more than 30” from grade -Install cooktop and hood in kitchen -Dishwasher discharge line should go high and then low for disposal connection -High/low vents required at mechanical room for combustion air -Clip set screw on anti siphon on spigot at main water line in basement -Flue b vent at furnace requires 1” clearance from combustibles, secure UFER ground wire off b vent -Hot water heater blowout discharge line requires termination above floor not less than 2 times the pipe diameter, maximum 6" -Install lights at master bath vanity -Tempered glass required at window in master bath shower
Sidewalk Inspection Partial 3/24/2021 3/24/2021 03/24/2021
Misc
Informational
03/24/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/25/2021 3/25/2021 03/25/2021
Misc
Corrective Action Required
03/24/2021
-Final grade and sod -splash blocks and sump pump discharge extension required -seal all penetrations in siding, seal along top of AC disconnect and meter can -Guardrail required at front porch, more than 30” from grade -Tempered glass required at window in master bath shower "replace light fixtures, attic access covers, switch and outlet covers removed in garage for painters"
Occupancy Inspection - Codes Residential Temporary C of O 3/26/2021 3/26/2021 03/26/2021
Misc
Corrective Action Required
03/25/2021
-Final grade and sod -splash blocks and sump pump discharge extension required -seal all penetrations in siding, seal along top of AC disconnect and meter can -Guardrail required at front porch, more than 30” from grade OK FOR TCO - TCO EXPIRES 4/16/21
Sidewalk Inspection Passed 3/31/2021 3/31/2021 04/01/2021
Misc
Informational
03/24/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 4/7/2021 4/7/2021 04/07/2021
Misc
Corrective Action Required
03/26/2021
-RESOLVE OUTSTANDING INSPECTION FEES - (4) OCCUPANCIES CURRENTLY, (5) ALL ROUGH INSPECTIONS, ONLY (3) REINSPECTION FEES ADDED -OBTAIN LAWN IRRIGATION SYSTEM PERMIT -BURY SEWER TRACER BOX IN GRADE, ENSURE REMAINS ACCESIBLE FOR LOCATE -SPLASH BLOCK AT SE CORNER DOWNSPOUT OK FOR TCO - TCO EXPIRES 4/16/21
Occupancy Inspection - Codes Residential Full C of O 4/9/2021 4/9/2021 04/09/2021
Misc
Resolved
04/09/2021
Plot Plan Inspection Passed 04/09/2021
Documents & Images
Date Uploaded File Type Document Name
09/30/2020 Application Form Permit Application and license tax form
10/02/2020 Approved Plans Approved Drawings
10/02/2020 Approved Plans Approved Truss Layout
10/02/2020 Approved Plans Approved Truss Package
10/02/2020 Plot Plan Approved Plot Plan
10/02/2020 Receipt Receipt for transaction:2020-006660
10/02/2020 Letter DS Building Permit
10/16/2020 Letter INSPECTION SUMMARY
11/04/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/16/2020 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/24/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/26/2021 Letter Codes Temporary Certificate of Occupancy
04/01/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/07/2021 Receipt Receipt for transaction:2021-001817
04/09/2021 Letter Field Certificate of Occupancy
04/09/2021 Letter Codes Final Certificate of Occupancy
04/09/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home