Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/10/2020 09/10/2020
Kim Brennan
Basement elevation
Corrective Action Required
09/08/2020

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) MDP calls for a daylight on this lot and you are proposing a walkout. Please explain.
Residential Plan Review Approved 09/10/2020 09/08/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,242.80 $1,242.80 Paid 09/10/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/10/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/10/2020
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 09/10/2020
8331507-Sewer Connection Fee $630.00 $630.00 Paid 09/10/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/10/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/10/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 04/06/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 04/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/29/2020 (1:15) 9/29/2020 09/29/2020
Underslab Plumbing Inspection - Residential Passed 10/20/2020 10/20/2020 10/20/2020
Piers/Caissons Inspection - Residential Passed 12/17/2020 (9:30) 12/17/2020 12/17/2020
All Rough Inspection - Residential Failed 1/14/2021 1/14/2021 01/14/2021
Misc
Corrective Action Required
01/14/2021
-Install anchor nut/bolt sgl car garage portal frame -Bocca protection plates at all DWV and pex at top and bottom plates within 1 1/2” end of plate -structural straps at top plates bored 50% or more on interior load bearing walls and all exterior walls require (4) nails rack side of strap -solid Fireblock at HVAV/DWV furr out in garage, area too large for loose insulation fill -Fireblock unused floor bore at 1st floor bath -security blocking - back door -Fireblock deadspace at refrigerator next to garage entrance -Fireblock deadspace at fireplace bump out top -unable to verify trusses/hangers/H2.5 clips at front porch and covered deck -Attic access garage per plans -LIB bracing per plans -garage -Solid block between joists at dining room/living room load bearing wall -connect 2x6 to 2x4 top plates 2nd floor -12” oc nailing at all intersecting and abutting wall corners (braced walls) -frame for jacuzzi tub motor access door -Fireblock deadspace at bed #2 door -Truss hanger at truss E7 2nd floor per plans -Truss bracing per plans -solid block between joists every 48” oc at kitchen island per plans -(2) bolts at post/beam connection deck -Complete nailing pattern at exterior sheathing per plan -Provide angel clip to end joist/ ledger connection -Provide (2) bolts per post/ joist connection at deck -Lag bolts at deck ledger per code, attach ledger to cantilever per detail 10 S2.0 in plans
Gas Piping Inspection - Residential Passed 1/14/2021 1/14/2021 01/14/2021
Gas Service Inspection - Residential Passed 1/14/2021 1/14/2021 01/14/2021
Electrical Service Inspection Failed 1/14/2021 1/14/2021 01/14/2021
Misc
Corrective Action Required
01/14/2021
-GEC CONNECT TO UFER GROUND LOCATED AT GARAGE WALL
Electrical Service Inspection Passed 1/15/2021 1/15/2021 01/15/2021
Misc
Resolved
01/15/2021
All Rough Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/14/2021
-Bocca protection plates at all DWV and pex at top and bottom plates within 1 1/2” end of plate -structural straps at top plates bored 50% or more on interior load bearing walls and all exterior walls require (4) nails rack side of strap -solid Fireblock at HVAV/DWV furr out in garage, area too large for loose insulation fill -unable to verify trusses/hangers/H2.5 clips at front porch and covered deck -connect 2x6 to 2x4 top plates 2nd floor -Complete nailing pattern at exterior sheathing per plan -Provide angel clip to end joist/ ledger connection -Lag bolts at deck ledger per code, attach ledger to cantilever per detail 10 S2.0 in plans
Sewer Service Inspection - R Passed 1/14/2021 (9:00) 1/19/2021 01/19/2021
Water Service Inspection - R Passed 1/19/2021 1/19/2021 01/19/2021
All Rough Inspection - Residential Not Ready 1/21/2021 1/21/2021 01/21/2021
Misc
Corrective Action Required
01/19/2021
-NOT APPROVED TO BE INSULATED- -REMOVE INSULATION FOR INSPECTION -Bocca protection plates at all DWV and pex at top and bottom plates within 1 1/2” end of plate -structural straps at top plates bored 50% or more on interior load bearing walls and all exterior walls require (4) nails rack side of strap -unable to verify trusses/hangers/H2.5 clips at front porch and covered deck -connect 2x6 to 2x4 top plates 2nd floor -Complete nailing pattern at exterior sheathing per plan -Provide angel clip to end joist/ ledger connection -Lag bolts at deck ledger per code, attach ledger to cantilever per detail 10 S2.0 in plans
All Rough Inspection - Residential Failed 1/25/2021 1/25/2021 01/25/2021
Misc
Corrective Action Required
01/21/2021
-Lag bolts at deck ledger per code, attach ledger to cantilever per detail 10 S2.0 in plans **OK TO INSULATE AND ROCK**
Driveway Inspection Partial 3/1/2021 3/1/2021 03/02/2021
Misc
Informational
03/02/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/1/2021 3/1/2021 03/02/2021
Misc
Informational
03/02/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/9/2021 3/9/2021 03/22/2021
Misc
Informational
03/02/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/9/2021 3/9/2021 03/22/2021
Misc
Informational
03/02/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 4/5/2021 4/5/2021 04/05/2021
Misc
Corrective Action Required
04/05/2021
-Resolve all outstanding inspection fee(s) before final c of o -Final grade and sod -Obtain lawn irrigation system permit -Guardrail required at front porch, more than 30” from grade -splash blocks at all downpour and sump pump discharge locations, minimum 36” distance from foundation -seal all penetrations in siding, seal along top of meter can and AC disconnect -Security screws at back door and basement walkout, (2) 3” screws required at strike plate and each hinges -seal garage door bracket ceiling penetrations though rock -AFCI protection required at all locations per E3902.16 -Hot water heater blowout pipe minimum distance to floor, 2 times the diameter of pipe minimum, maximum 6” AFF -Exterior light at walkout must be sealed, tamper resistant type, less than 8’ from walking surface
All Rough Inspection - Residential Passed 04/05/2021
Misc
Resolved
04/05/2021
Occupancy Inspection - Codes Residential Temporary C of O 4/7/2021 4/7/2021 04/07/2021
Misc
Corrective Action Required
04/05/2021
-Final grade and sod OK FOR TCO - TCO EXPIRES 4/28/21
Plot Plan Inspection Failed 4/20/2021 4/20/2021 04/20/2021
Misc
Corrective Action Required
04/20/2021
-UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE AT NE OF REAR LOT AS SHOWN ON PLOT PLAN-
Occupancy Inspection - Codes Residential Failed 4/20/2021 4/20/2021 04/20/2021
Misc
Corrective Action Required
04/07/2021
-SEE PLOT PLAN INSPECTION REPORT -UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE AT NE OF REAR LOT AS SHOWN ON PLOT PLAN- OK FOR TCO - TCO EXPIRES 4/28/21
Plot Plan Inspection Passed 5/3/2021 5/3/2021 05/03/2021
Misc
Resolved
05/03/2021
Occupancy Inspection - Codes Residential Full C of O 5/3/2021 5/3/2021 05/03/2021
Misc
Resolved
05/03/2021
Documents & Images
Date Uploaded File Type Document Name
09/04/2020 Application Form Permit Application and license tax form
09/08/2020 Letter Codes Residential Plan Review
09/08/2020 Approved Plans Approved Drawings
09/08/2020 Approved Plans Approved Truss Package
09/08/2020 Approved Plans Approved Truss Layout
09/10/2020 Approved Plans Letter approving walkout basement
09/10/2020 Plot Plan Approved Plot Plan
09/10/2020 Receipt Receipt for transaction:2020-006114
09/10/2020 Letter DS Building Permit
09/29/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
12/17/2020 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/06/2021 Receipt Receipt for transaction:2021-001775
04/07/2021 Letter Codes Temporary Certificate of Occupancy
04/20/2021 Letter INSPECTION SUMMARY
04/20/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter Field Certificate of Occupancy
05/03/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home