Permit Application Status

PRRES20202669


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202669
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
08/31/2020
11/02/2020
09/12/2022
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
Reliable Mechanical Services, Inc. , Address:1025 W Couchman Dr.  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/02/2020 09/10/2020
Dylan Eppert
Basement egress
Corrective Action Required
09/02/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. PLEASE CONFIRM LOCATION OF EGRESS WITH BUILDER. IF THIS IS THE CORRECT SPOKE THE EGRESS WELL WILL NEED TO BE CHANGED ON THE HOUSE PLANS.
Miscellaneous Correction
Corrective Action Required
09/02/2020

Safehouse electric Company doesn't have an active business license and will need to before I can issue the permit.
Residential Plan Review Approved 09/02/2020 09/02/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,017.55 $1,017.55 Paid 11/02/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 11/02/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 11/02/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 11/02/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/02/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/02/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 09/01/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/4/2020 (1:00) 12/4/2020 12/04/2020
Misc
Informational
12/04/2020
Please provide building address and gravel filter at drive
Sewer Service Inspection - R Passed 1/19/2021 (1:00) 1/19/2021 01/19/2021
Water Service Inspection - R Partial 01/19/2021
Misc
Corrective Action Required
01/19/2021
Partial approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 1/20/2021 (3:00) 1/20/2021 01/20/2021
Misc
Resolved
01/20/2021
Partial approval from structure to metallic connection customer side of meter
Miscellaneous Inspection Failed 01/20/2021
Misc
Corrective Action Required
01/20/2021
Post site address
Underslab Plumbing Inspection - Residential Failed 1/29/2021 1/29/2021 01/29/2021
Misc
Corrective Action Required
01/29/2021
Protect water service at concrete floor penetration
Erosion Control Inspection Residential Failed 01/29/2021
Misc
Corrective Action Required
01/29/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -provide and maintain gravel filter -no further inspections until issues are resolved
Erosion Control Inspection Residential Failed 02/03/2021
Misc
Partial Correction
02/03/2021
-provide and maintain gravel filter
Miscellaneous Inspection Passed 02/03/2021
Misc
Resolved
02/03/2021
Post site address
Underslab Plumbing Inspection - Residential Passed 2/25/2021 2/25/2021 02/25/2021
Misc
Resolved
02/25/2021
Protect water service at concrete floor penetration
Piers/Caissons Inspection - Residential Passed 3/29/2021 (9:00) 3/29/2021 03/29/2021
All Rough Inspection - Residential Partial 3/29/2021 3/29/2021 03/29/2021
Misc
Informational
03/29/2021
portal frame approved
All Rough Inspection - Residential Failed 4/30/2021 4/30/2021 04/30/2021
Misc
Informational
03/29/2021
portal frame approved
Miscellaneous Correction
Corrective Action Required
04/30/2021
-Maintain silt fence at perimeter and gravel filter at drive -Complete nailing pattern at exterior sheathing
Miscellaneous Correction
Corrective Action Required
04/30/2021
-Maintain silt fence at perimeter and gravel filter at drive -Complete nailing pattern at exterior sheathing -Tighten anchor bolts in garage -Anchor bolts to be in middle third of plate at single car bay and NW corner -Provide anchor bolt at plate break west wall -Provide anchor bolt at end of plate east and north walls -Seal all plate penetrations throughout -Fireblock notched joist at DWV in garage -Fireblock tub traps -Seal all floor penetrations -Fur out for walls and ceiling in garage for insulation at mechanical -Nail double joists per code -Nail joist laps per code -Nail joist to rafters per code -Address rafters not landing on top plate/ not connected to joists -Structural strap at DWV and mechanical bores in top plate over 50% to extend 6" past bore each direction in garage/pantry and stairwell -Seal seam in FB at fireplace -FB HVAC chases in kitchen and upper level -Rafters not attached to joists at dining -Mechanical incomplete by kitchen -Fur out and Fireblock at mechanical in kitchen -Missing range circuit -Provide stud shoes at bored studs in exterior wall for medial at fireplace -Sheathing not nailed to top plate throughout upstairs -Provide snow blocking at master bed, master bath and upstairs bed -Repair moisture barrier and sheathing at snow blocking locations -Nail sheathing in master bed -Nail joists to hangers throughout upstairs -Provide joist hangers at all joists over 4'- closet wall and south hallway wall are not loadbearing walls -Provide protection plate and midpoint strap at DWV in blocking at upstairs tub exterior wall -Address beam in basement not fully bearing in pocket- this requires an engineered correction -Land electrical in boxes in basement ceiling
Electrical Service Inspection Passed 4/30/2021 4/30/2021 04/30/2021
Gas Service Inspection - Residential Passed 4/30/2021 4/30/2021 04/30/2021
All Rough Inspection - Residential Failed 5/17/2021 5/17/2021 05/17/2021
Misc
Informational
04/30/2021
portal frame approved
Miscellaneous Correction
Corrective Action Required
04/30/2021
-Maintain silt fence at perimeter and gravel filter at drive 5/17/21 inspection denied due to lack of compliance with above required corrective action
Miscellaneous Correction
Corrective Action Required
04/30/2021
-Maintain silt fence at perimeter and gravel filter at drive -Complete nailing pattern at exterior sheathing -Tighten anchor bolts in garage -Anchor bolts to be in middle third of plate at single car bay and NW corner -Provide anchor bolt at plate break west wall -Provide anchor bolt at end of plate east and north walls -Seal all plate penetrations throughout -Fireblock notched joist at DWV in garage -Fireblock tub traps -Seal all floor penetrations -Fur out for walls and ceiling in garage for insulation at mechanical -Nail double joists per code -Nail joist laps per code -Nail joist to rafters per code -Address rafters not landing on top plate/ not connected to joists -Structural strap at DWV and mechanical bores in top plate over 50% to extend 6" past bore each direction in garage/pantry and stairwell -Seal seam in FB at fireplace -FB HVAC chases in kitchen and upper level -Rafters not attached to joists at dining -Mechanical incomplete by kitchen -Fur out and Fireblock at mechanical in kitchen -Missing range circuit -Provide stud shoes at bored studs in exterior wall for medial at fireplace -Sheathing not nailed to top plate throughout upstairs -Provide snow blocking at master bed, master bath and upstairs bed -Repair moisture barrier and sheathing at snow blocking locations -Nail sheathing in master bed -Nail joists to hangers throughout upstairs -Provide joist hangers at all joists over 4'- closet wall and south hallway wall are not loadbearing walls -Provide protection plate and midpoint strap at DWV in blocking at upstairs tub exterior wall -Address beam in basement not fully bearing in pocket- this requires an engineered correction -Land electrical in boxes in basement ceiling
Erosion Control Inspection Residential Failed 05/17/2021
Misc
Corrective Action Required
05/17/2021
-Maintain silt fence at perimeter and gravel filter at drive
All Rough Inspection - Residential Failed 5/19/2021 5/19/2021 05/19/2021
Misc
Informational
05/17/2021
portal frame approved
Miscellaneous Correction
Resolved
05/19/2021
-Maintain silt fence at perimeter and gravel filter at drive 5/17/21 inspection denied due to lack of compliance with above required corrective action
Miscellaneous Correction
Corrective Action Required
05/17/2021
-Complete nailing pattern at exterior sheathing -Tighten anchor bolt in garage -Nail joist to rafters per plan. Rafter bearing option three requires 3-16d at rafter to joist connections 6/S-1.2 — 3-10d at all other rafter/joist parallel heel joint locations, fastening schedule S-1.0 -Address beam in basement not fully bearing in pocket- this requires an engineered correction
All Rough Inspection - Residential Failed 6/4/2021 6/4/2021 06/04/2021
Misc
Informational
05/19/2021
portal frame approved
Miscellaneous Correction
Corrective Action Required
05/19/2021
-Complete nailing pattern at exterior sheathing. Minimum 6” edge & 12” field Ok to insulate and rock. Do not paint exterior until exterior sheathing fastening correction is resolved
Driveway Inspection Partial 8/3/2021 08/03/2021
Sidewalk Inspection Partial 8/3/2021 08/03/2021
Driveway Inspection Passed 8/5/2021 8/5/2021 08/05/2021
Sidewalk Inspection Passed 8/5/2021 08/05/2021
Occupancy Inspection - Codes Residential Failed 9/7/2021 9/7/2021 09/07/2021
Misc
Corrective Action Required
09/07/2021
-Provide erosion control at perimeter until sod is in place, clean mud from sidewalks, protect street and sidewalk. No further inspections until in compliance -Final grade and sod, splash blocks -Seal top of meter can, AC disconnect and all exterior penetrations -Clean debris from window well -Install stop at front sidelight windows -Patch holes in rock at garage/ dwelling separation -Anchor steel column base -Patch rock at dining room receptacle under window -Replace broken ring at water meter pit
All Rough Inspection - Residential Passed 09/07/2021
Misc
Resolved
09/07/2021
portal frame approved
Miscellaneous Correction
Resolved
09/07/2021
-Complete nailing pattern at exterior sheathing. Minimum 6” edge & 12” field Ok to insulate and rock. Do not paint exterior until exterior sheathing fastening correction is resolved
Occupancy Inspection - Codes Residential Temporary C of O 9/14/2021 9/14/2021 09/14/2021
Misc
Corrective Action Required
09/07/2021
-Final grade and sod, splash blocks -Replace broken ring at water meter pit **lower the meter lid to flush with final grade
Erosion Control Inspection Residential Passed 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
-Maintain silt fence at perimeter and gravel filter at drive
Plot Plan Inspection Passed 9/12/2022 09/12/2022
Occupancy Inspection - Codes Residential Full C of O 9/12/2022 9/12/2022 09/12/2022
Misc
Resolved
09/12/2022
-Final grade and sod, splash blocks -Replace broken ring at water meter pit **lower the meter lid to flush with final grade
Documents & Images
Date Uploaded File Type Document Name
08/31/2020 Scope of Work 2330 SW Old Port Rd - License Tax Application
08/31/2020 Scope of Work 2330 SW Old Port Rd - Permit Application
08/31/2020 LOT 727 FINAL PLOT PLAN
08/31/2020 DW Permit Plan Parker GR 2330 SW Old Port Rd Lot 727 Eagle Creek
09/02/2020 Letter Codes Residential Plan Review
09/10/2020 Plot Plan APPROVED PLOT PLAN
09/23/2020 Plans APPROVED HOUSE PLANS
11/02/2020 Receipt Receipt for transaction:2020-007311
11/02/2020 Letter DS Building Permit
12/04/2020 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
04/30/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter INSPECTION SUMMARY
06/02/2021 2330 SW Old Port Road - Structural Letter (June 2, 2021)
06/04/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
08/05/2021 Letter INSPECTION SUMMARY
09/01/2021 Receipt Receipt for transaction:2021-007054
09/07/2021 Letter INSPECTION SUMMARY
09/07/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter Codes Temporary Certificate of Occupancy
02/01/2022 Letter Codes 140 Day Letter
02/23/2022 Letter Codes 140 Day Letter
09/12/2022 Letter Codes Final Certificate of Occupancy
09/12/2022 Letter Field Certificate of Occupancy
09/12/2022 Letter INSPECTION SUMMARY
09/12/2022 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home