Permit Application Status

PRRES20202364


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202364
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ENGINEERED FLOOR SYSTEM - UNFINISHED BASEMENT
08/17/2020
08/31/2020
09/22/2021
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
PERMITTING@JFECONSTRUCTION.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 08/24/2020 08/31/2020
Dylan Eppert
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
08/24/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) MISSING BASEMENT SQ FOOTAGE.
06 Designate use of each room or space
Corrective Action Required
08/24/2020

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. MASTER BATH APPEARS TO NOT HAVE ANY SINKS IS PLEASE CLARIFY.
Plot Plan Review Approved 08/24/2020 08/25/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,342.51 $1,342.51 Paid 08/31/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 08/31/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/31/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/31/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/31/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/31/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/14/2021 (1:00) 1/14/2021 01/14/2021
Sewer Service Inspection - R Passed 2/4/2021 (9:15) 2/4/2021 02/04/2021
Underslab Plumbing Inspection - Residential Failed 2/5/2021 2/5/2021 02/05/2021
Misc
Corrective Action Required
02/05/2021
Connect interior underslab drain tile to Sump pit
Water Service Inspection - R Passed 2/5/2021 02/05/2021
Erosion Control Inspection Residential Failed 2/24/2021 02/24/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/24/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Passed 2/24/2021 2/24/2021 02/24/2021
Misc
Resolved
02/24/2021
Electrical Service Inspection Passed 5/5/2021 05/05/2021
Gas Service Inspection - Residential Passed 5/5/2021 05/05/2021
All Rough Inspection - Residential Failed 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
05/05/2021
FRAMING: -Nail siding to sill plate at rear corner of house adjacent to window well -Nail rear living room CSPF wall siding to rim band, studs , and header per plan detail. Not supposeD to have any seam in siding just below header; install straps and nail front dining room CSPF wall per plan; frame CSPF wall at front stair wall per plan -Fb garage vertical space from soffit/roof space -Install a wall stud continuous from sill plate to top plate at garage/stoop wall adjacent to timber beam -Support ridge end and valley rafter at ridge above 2nd fl front bedroom ELECTRICAL: -For foyer larger than 5.6 sq meters, provide a wall receptacle for wall space wider than 3 ft **OK TO INSULATE
All Rough Inspection - Residential Passed 5/21/2021 5/21/2021 05/21/2021
Misc
Resolved
05/21/2021
FRAMING: -Nail siding to sill plate at rear corner of house adjacent to window well -Nail rear living room CSPF wall siding to rim band, studs , and header per plan detail. Not supposeD to have any seam in siding just below header; install straps and nail front dining room CSPF wall per plan; frame CSPF wall at front stair wall per plan -Fb garage vertical space from soffit/roof space -Install a wall stud continuous from sill plate to top plate at garage/stoop wall adjacent to timber beam -Support ridge end and valley rafter at ridge above 2nd fl front bedroom ELECTRICAL: -For foyer larger than 5.6 sq meters, provide a wall receptacle for wall space wider than 3 ft **OK TO INSULATE
Driveway Inspection Passed 6/4/2021 6/4/2021 06/07/2021
Erosion Control Inspection Residential Passed 09/14/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/14/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Occupancy Inspection - Codes Residential Temporary C of O 9/14/2021 9/14/2021 09/14/2021
Misc
Corrective Action Required
09/14/2021
-FINAL GRADE, SOD, DOWNSPOUT EXTENSIONS OR SPLASH BLOCKS -MAKE SURE THE WATER METER LID IS AT FINAL GRADE LEVEL
Occupancy Inspection - Codes Residential Full C of O 9/22/2021 9/22/2021 09/22/2021
Misc
Resolved
09/22/2021
-FINAL GRADE, SOD, DOWNSPOUT EXTENSIONS OR SPLASH BLOCKS -MAKE SURE THE WATER METER LID IS AT FINAL GRADE LEVEL
Documents & Images
Date Uploaded File Type Document Name
08/17/2020 Scope of Work 1097_001
08/17/2020 Scope of Work 1098_001
08/20/2020 EC-710
08/20/2020 20-07384 Silverton III Rev 1-plot 2nd floor only_VDA Review_8-20-20
08/20/2020 EC #710_2358 SW RIVER TRAIL RD_PERMIT_7-20-20
08/20/2020 Drawing APPROVED I JOIST PACKAGE
08/25/2020 Letter Codes Residential Plan Review
08/25/2020 Plot Plan APPROVED PLOT PLAN
08/31/2020 Plans APPROVED HOUSE PLAN
08/31/2020 Receipt Receipt for transaction:2020-005860
08/31/2020 Letter DS Building Permit
01/14/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/19/2021 2358 SW River Run Trail Rd_Framing Evaluation Report_5-19-21
05/21/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter Codes Temporary Certificate of Occupancy
09/22/2021 Letter Codes Final Certificate of Occupancy
09/22/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home