Summary
PRRES20202177
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
08/05/2020
08/14/2020
05/18/2021
Locations
Contacts
ROBERT A WASHAM CONSTRUCTION INC, Address:2058 NW SOUTH OUTER RD, Phone:(816) 224-5583  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
MARKV@ROBWASHAMHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/10/2020 08/14/2020
Kim Brennan
Property boundary
Corrective Action Required
08/07/2020

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. No distance or bearings shown on the right side of the lot
Misc
Corrective Action Required
08/07/2020

If a grinder pump is going to be used on this lot, the city requires the location of it to be drawn on the plot plan, as well the direction in which it will flow. The city also requires what type of grinder pump will be used to make sure that it is one of the systems approved by the city. Please provide the literature and drawing of the actual pump being used.
Residential Plan Review Approved 08/10/2020 08/06/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,478.20 $1,478.20 Paid 08/14/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 08/14/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/14/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/14/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/14/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/14/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/1/2020 (3:00) 9/1/2020 09/01/2020
Erosion Control Inspection Residential Failed 09/16/2020
Misc
Corrective Action Required
09/16/2020
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site
Sewer Service Inspection - R Passed 9/25/2020 (10:00) 9/25/2020 09/25/2020
Water Service Inspection - R Passed 9/25/2020 (10:00) 9/25/2020 09/25/2020
Underslab Plumbing Inspection - Residential Passed 10/5/2020 10/5/2020 10/05/2020
All Rough Inspection - Residential Partial 12/3/2020 12/3/2020 12/02/2020
Misc
Informational
12/02/2020
Portal frame approved
All Rough Inspection - Residential Failed 12/31/2020 12/31/2020 12/31/2020
Misc
Corrective Action Required
12/31/2020
Inspection denied, city approved plans must be on site for inspections
All Rough Inspection - Residential Failed 1/4/2021 1/4/2021 01/04/2021
Misc
Corrective Action Required
01/04/2021
-Missing exterior window, rear of structure -12” oc fastening stud to stud and abutting studs at intersecting braced walls -Properly fasten and ground metallic lighting outlet box over dining room -Fasten fireplace to framing -Seal penetration in stud where stud cavity is used as return Plenum, shelf/master hall wall -Provide security blocking, master bedroom exterior door -Complete bath/toilet room exhaust duct and termination per code -Midpoint support for all vertical 2” and smaller DWVV -Fireblock vertical to horizontal at both sides of front bedroom closet door -Provide stud shoe at over-bored stud penetration loadbearing wall, front bedroom closet -Fireblock all through floor penetrations -First and second floor bottom plate fastening per plan -Over bored load bearing interior top plates require structural straps that span minimum 6” beyond each side of penetrations with minimum 4-10D nails each side -four 2x4 under header at mud room/kitchen door per plan -three LVL above master walk-in -Provide purlins as shown on the plan -provide proper end support of all hips & valleys -Complete return air path, upstairs front bedroom -Fireblock vertical to horizontal, wall between loft and bedroom -Anchor steel columns -Provide solid blocking at all cantilevers and above all beams -Address damaged 2x10 floor joist for plumbing installation, basement -provide minimum unobstructed 30” height vertical clearance at second story attic access, duct blocking access -Provide king studs for headers right side of entry door -unable to verify anchor bolt placement and fastening per code, master bed south wall & dining north wall -fire block vertical to horizontal at fireplace -provide Stud shoe at master bath lav, 2” DWV stud penetration -Load bearing 2x4 wall between stairs to basement and foundation wall is supporting two floors plus roof/ceiling assembly. Provide engineered solution for repair or comply with table R602.3(5)
Electrical Service Inspection Passed 12/31/2020 01/04/2021
Gas Piping Inspection - Residential Passed 12/31/2020 01/04/2021
Gas Service Inspection - Residential Passed 12/31/2020 01/04/2021
All Rough Inspection - Residential Failed 1/15/2021 1/15/2021 01/15/2021
Misc
Corrective Action Required
01/04/2021
-Fireblock all through floor penetrations -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -Provide purlins as shown on the plan -Complete return air path, upstairs front bedroom -Provide solid blocking above all beams. second floor framing, beam between kitchen & living room
All Rough Inspection - Residential Failed 1/21/2021 1/21/2021 01/21/2021
Misc
Corrective Action Required
01/15/2021
-Provide solid blocking above all beams. second floor framing, beam between kitchen & living room
All Rough Inspection - Residential Passed 1/25/2021 1/25/2021 01/22/2021
Misc
Resolved
01/22/2021
-Provide solid blocking above all beams. second floor framing, beam between kitchen & living room
Driveway Inspection Passed 4/7/2021 4/7/2021 04/07/2021
Plot Plan Inspection Failed 4/27/2021 04/27/2021
Misc
Corrective Action Required
04/27/2021
-water meter pit lid to be at grade level and meter to be 14-18” below lid -water valve box lids to be at grade level, repair damaged risers & lids and remove debris from risers
Occupancy Inspection - Codes Residential Failed 5/4/2021 5/4/2021 05/04/2021
Misc
Corrective Action Required
05/04/2021
-Maintenance of erosion control methods is required until sod is in place -final grade and sod -address issues with failed plot plan inspection -Remove mud and debris from sidewalk and street -Driveway and sidewalk inspections pending -Seal exterior penetrations -Downspouts to discharge minimum 36 inches from foundation -Ensure minimum 6 inches fall in grade at 10 foot from foundation -Secure raceway at AC disconnect -Identify white insulated conductors to be used as current carrying conductors at both points of termination. AC circuit -Remove screen from clothes dryer vent termination -Address water leak in meter pit -Provide water hammer arrestors at clothes washing connection -Install weatherstrip at garage/dwelling separation door -Fireblock through floor Penetrations under kitchen island, easily accessible from basement -maximum gap of 1/8” between outlet boxes and gypsum, main level bath and pantry -secure water distribution piping to foundation wall -provide hose connection type backflow prevention device at hose bib water system drain
Plot Plan Inspection Passed 05/11/2021
Misc
Resolved
05/11/2021
-water meter pit lid to be at grade level and meter to be 14-18” below lid -water valve box lids to be at grade level, repair damaged risers & lids and remove debris from risers
Occupancy Inspection - Codes Residential Temporary C of O 5/11/2021 5/11/2021 05/11/2021
Misc
Corrective Action Required
05/04/2021
-Maintenance of erosion control methods is required until sod is in place -final grade and sod -Remove mud and debris from sidewalk and street -Driveway and sidewalk inspections pending, contact Development Services to resolve this issue -Seal exterior penetrations -Downspouts to discharge minimum 36 inches from foundation -Ensure minimum 6 inches fall in grade at 10’ from foundation, rear of structure -Lawn irrigation permit required TCO VALID THROUGH 06/11/2021
Sidewalk Inspection Passed 4/5/2021 4/5/2021 05/11/2021
Misc
Informational
05/11/2021
On Tuesday I preformed a sidewalk inspection and passed inspection of city sidewalk.
Erosion Control Inspection Residential Passed 05/18/2021
Misc
Resolved
05/18/2021
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete -Street cleanup required immediately. No further inspections until complete -Remove trash from site
Occupancy Inspection - Codes Residential Full C of O 5/19/2021 5/19/2021 05/18/2021
Misc
Resolved
05/18/2021
-Maintenance of erosion control methods is required until sod is in place -final grade and sod -Remove mud and debris from sidewalk and street -Driveway and sidewalk inspections pending, contact Development Services to resolve this issue -Seal exterior penetrations -Downspouts to discharge minimum 36 inches from foundation -Ensure minimum 6 inches fall in grade at 10’ from foundation, rear of structure -Lawn irrigation permit required TCO VALID THROUGH 06/11/2021
Documents & Images
Date Uploaded File Type Document Name
08/05/2020 Letter Permit Application and license tax form
08/07/2020 Drawing Approved Drawings
08/07/2020 Letter Codes Residential Plan Review
08/13/2020 Plot Plan Approved Plot Plan
08/14/2020 Drawing LIBERTY-P380-Series-Grinder Pump Spec-Sheet
08/14/2020 Receipt Receipt for transaction:2020-005250
08/14/2020 Letter DS Building Permit
09/01/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
12/02/2020 Letter INSPECTION SUMMARY
12/31/2020 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/14/2021 APEX
01/15/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
04/26/2021 Plot Plan Approved As Graded Plot Plan
04/27/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/05/2021 1801 RIVER DRIVE AS GRADED PLOT PLAN REV1
05/05/2021 LIBERTY-P380-Series-Grinder Pump Spec-Sheet (2)
05/11/2021 Letter INSPECTION SUMMARY
05/11/2021 Letter Codes Temporary Certificate of Occupancy
05/11/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter Codes Final Certificate of Occupancy
05/18/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home