Summary
PRRES20202026
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK
07/21/2020
08/11/2020
01/24/2021
05/05/2021
Locations
Contacts
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
NZVACEK@GMAIL.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
COMFORT SYSTEMS HTG/CLG, Address:17232 BEL-RAY PL, Phone:(816) 322-1013  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/28/2020 08/03/2020
Steve Conrick
Spot elevations
Corrective Action Required
07/28/2020

Spot elevations, contours, and drainage flow arrows shall be provided throughout the lot. Please provide proposed contours. i see 1016 and 1017 but not 1018 or 1019.
As-graded plot plan
Corrective Action Required
07/28/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 07/28/2020 07/28/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,291.34 $1,291.34 Paid 08/11/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/11/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/11/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 08/11/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/11/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/20/2020 (3:00) 8/20/2020 08/20/2020
Underslab Plumbing Inspection - Residential Passed 10/16/2020 10/16/2020 10/16/2020
Gas Service Inspection - Residential Passed 12/23/2020 12/23/2020 12/23/2020
Electrical Service Inspection Passed 12/23/2020 12/23/2020 12/23/2020
All Rough Inspection - Residential Failed 12/23/2020 12/23/2020 12/23/2020
Misc
Corrective Action Required
12/23/2020
-Nail garage portal wall sheathing to sill plate w/8d@3” oc -Block joists below wall line above garage -Strap cut top plate at mud air plenum wall -Strap interior bearing wall top plates where bored more than 50% -Protect plumbing at master bathroom wall top plate -Protect wiring at rear master bedroom wall -Complete framing at fireplace and fasten fireplace to framing -Security block rear exterior door stud to corner -Install hangers at kitchen ceiling beam connections to lvl -Shim gap at lvl roof beam support stud at rear bedroom -Protect plumbing at rear bedroom closet -Snow block at front bedroom (above foyer) step flashings and nail all siding to studs per code -Insulate first, then solid block all cantilevered joists **OK TO INSULATE
Water Service Inspection - R Passed 12/30/2020 (10:45) 12/30/2020 12/30/2020
All Rough Inspection - Residential Passed 12/31/2020 12/31/2020 12/31/2020
Misc
Resolved
12/31/2020
Sewer Service Inspection - R Passed 12/23/2020 (1:30) 12/23/2020 01/04/2021
Piers/Caissons Inspection - Residential Passed 2/5/2021 2/5/2021 02/05/2021
Erosion Control Inspection Residential Failed 2/5/2021 2/5/2021 02/05/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
02/05/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/05/2021
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -MAINTAIN EROSION CONTROL AT FRONT OF LOT -CLEAN MUD AND GRAVEL IN STREET
Driveway Inspection Partial 3/23/2021 03/23/2021
Misc
Informational
03/23/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/30/2021 3/30/2021 03/30/2021
Misc
Informational
03/23/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 4/27/2021 04/27/2021
Misc
Corrective Action Required
04/27/2021
-final grade and sod -splash blocks at all downspouts and sump pump discharge, minimum 36" discharge from foundation -backfill at egress well -Tamper proof caps on AC compressor valves OK FOR TCO - TCO EXPIRES
Occupancy Inspection - Codes Residential Failed 5/3/2021 5/3/2021 05/03/2021
Misc
Corrective Action Required
04/27/2021
-Submit as graded plot plan for approval -backfill at egress well OK FOR TCO - TCO EXPIRES 5/11/21
Plot Plan Inspection Passed 5/5/2021 05/05/2021
Occupancy Inspection - Codes Residential Full C of O 5/5/2021 05/05/2021
Misc
Resolved
05/05/2021
Documents & Images
Date Uploaded File Type Document Name
07/21/2020 Lot 70 Summit View Farms Permit Application (version 3)
07/21/2020 Lot 70 Summit View Farms Tax App (version 3)
07/24/2020 Lot 70 Summit View Farms Blue Print Submitted
07/24/2020 Lot 70 Summit View Farms Submitted Plot Plan
07/28/2020 Letter Codes Residential Plan Review
07/28/2020 APPROVED Lot 70 Summit View Farms Blue Print Submitted
08/03/2020 Lot 70 2020-07-29
08/03/2020 APPROVED Lot 70 2020-07-29
08/11/2020 Receipt Receipt for transaction: 2020-005093
08/11/2020 Letter DS Building Permit
08/20/2020 Letter INSPECTION SUMMARY
10/16/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/30/2020 Letter INSPECTION SUMMARY
12/31/2020 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
03/23/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter Codes Temporary Certificate of Occupancy
05/03/2021 Letter INSPECTION SUMMARY
05/05/2021 Plot Plan Approved As Graded Plot Plan
05/05/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home