Permit Application Status

PRRES20202025


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202025
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED DECK ROOF TRUSSES
07/21/2020
07/27/2020
06/21/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/24/2020 07/24/2020
Steve Conrick
Residential Plan Review Approved 07/24/2020 07/24/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,498.98 $1,498.98 Paid 07/27/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/27/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/27/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/27/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/27/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 07/27/2020
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 07/27/2020
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/18/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 06/18/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/28/2020 (11:30) 8/28/2020 08/28/2020
Sewer Service Inspection - R Passed 10/7/2020 (9:30) 10/7/2020 10/07/2020
Water Service Inspection - R Passed 10/8/2020 (11:30) 10/8/2020 10/08/2020
Erosion Control Inspection Residential Failed 10/9/2020 10/9/2020 10/09/2020
DCM5 ESC INSP DENIED
Corrective Action Required
10/09/2020
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. - MAINTAIN SILT FENCE -CLEAN MUD AND GRAVEL IN STREET
Underslab Plumbing Inspection - Residential Failed 10/9/2020 10/9/2020 10/09/2020
Misc
Corrective Action Required
10/09/2020
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. - MAINTAIN SILT FENCE -CLEAN MUD AND GRAVEL IN STREET
Underslab Plumbing Inspection - Residential Passed 10/30/2020 10/30/2020 10/30/2020
Misc
Resolved
10/30/2020
Piers/Caissons Inspection - Residential Passed 12/15/2020 (8:00) 12/15/2020 12/15/2020
Electrical Service Inspection Passed 1/19/2021 1/19/2021 01/19/2021
Gas Service Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/19/2021
-GAS PRESSURE AT 4 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/19/2021
-Fireblock HVAC chase at garage -Fireblock vertical to horizontal at furred down in garage -Garage PFH per plans -Connect flat 2x4 at furred down in garage to floor joists above to support the ceiling load -Fireblock deadspace at garage entry -Secure all vertical DWV 2” or less at mid point -Structural straps at all top plates bored 50% or more on all exterior walls and all interior load bearing walls -Fireblock DWV chase at 1st floor shower -Fireblock deadspace at both sides of door, 1st floor bedroom -Protect vertical gas flex line at 1st floor closet per manufacturer installation instructions -Seal gas flex line top plate penetration 1st floor closet -Protection plate at top and bottom plate pex -see pantry -B vent at kitchen chase requires 1” clearance from combustibles -secure gas flex line at fireplace 1st floor living room and 2nd floor master bed -Fireblock chase, E side great room windows -security blocking at exterior doors -Remove lid at both front porch and back patio to allow for inspection Timon of trusses/truss hangers/H2.5 clips -LIB bracing, all locations per plans -(2) 2x10 joist 1st floor between owner entry and flex room entrance to be supported on (3) 2x4 at ends per plans -(3) 2x4 at W wall dining room 1st floor at garage wall intersecting per plans -Connect 2x4 to 2x6 top plate at 2nd floor stairs -2.5 clips at all trusses above stairs -Fireblock deadspace bedroom #2 at door -Fireblock deadspace bedroom #2 between bedroom and bathroom -Truss H2.5 clip bath#2 -B vent requires 1” clearance from combustibles, 2nd floor hall HVAC chase -DWV vent pipe located above 2nd floor attic access, 30” vertical clearance required -Fireblock master bed fireplace lid, 2nd floor -Maintain proper fall at DWV vent pipes in attic space -Truss hangers per plans -Truss bracing per plans -Joist hangers required at stair landings 4’ or more
Gas Piping Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/19/2021
-secure gas flex line at fireplace 1st floor living room and 2nd floor master bed -Protect vertical gas flex line at 1st floor closet per manufacturer installation instructions
All Rough Inspection - Residential Failed 1/22/2021 1/22/2021 01/22/2021
Miscellaneous Correction
Corrective Action Required
01/22/2021
**Do not insulate ** -Fireblock HVAC chase at garage -Fireblock vertical to horizontal at furred down in garage-seal around dwv -Fireblock deadspace at garage entry-seal gaps -Structural straps at all top plates bored 50% or more on all exterior walls and all interior load bearing walls -Fireblock DWV chase at 1st floor shower-seal gaps -Fireblock deadspace at both sides of door, 1st floor bedroom-seal gaps -Protect vertical gas flex line at 1st floor closet per manufacturer installation instructions -B vent at kitchen chase requires 1” clearance from combustibles-add block to stop horizontal fire spread -Fireblock chase, E side great room windows-seal gaps -security blocking at exterior doors-seal gaps -Remove lid at both front porch to allow for inspection Timon of trusses/truss hangers/H2.5 clips -2.5 clips at all trusses above stairs -Fireblock deadspace bedroom #2 at door -Fireblock deadspace bedroom #2 between bedroom and bathroom -Truss H2.5 clip bath#2 -Fireblock master bed fireplace lid, 2nd floor -Truss hangers per plans-at G1 girder truss -Truss bracing per plans
All Rough Inspection - Residential Failed 1/26/2021 1/26/2021 01/26/2021
Miscellaneous Correction
Corrective Action Required
01/22/2021
**OK TO INSULATE** -Fireblock vertical to horizontal at furred down ends in garage -Structural straps at all top plates bored 50% or more on all exterior walls and all interior load bearing walls -see master bath exterior wall -Protect vertical gas flex line at 1st floor closet per manufacturer installation instructions -security blocking at exterior doors-seal gaps -Remove trim at front porch to allow for inspection of H2.5 clips -Truss hangers per plans-at G1 girder truss -Truss bracing per plans
Gas Service Inspection - Residential Passed 1/27/2021 1/27/2021 01/27/2021
Misc
Resolved
01/27/2021
Gas Piping Inspection - Residential Failed 1/27/2021 1/27/2021 01/27/2021
Misc
Corrective Action Required
01/19/2021
-Protect vertical gas flex line at 1st floor closet per manufacturer installation instructions
All Rough Inspection - Residential Failed 1/28/2021 1/28/2021 01/28/2021
Miscellaneous Correction
Corrective Action Required
01/26/2021
**OK TO INSULATE** -Protect vertical gas flex line at 1st floor closet per manufacturer installation instructions
All Rough Inspection - Residential Passed 1/29/2021 1/29/2021 01/29/2021
Miscellaneous Correction
Resolved
01/29/2021
Gas Piping Inspection - Residential Passed 1/29/2021 1/29/2021 01/29/2021
Misc
Resolved
01/29/2021
Driveway Inspection Partial 3/11/2021 3/11/2021 03/12/2021
Misc
Informational
03/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/19/2021 3/19/2021 03/22/2021
Misc
Informational
03/12/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 4/22/2021 4/22/2021 04/26/2021
Occupancy Inspection - Codes Residential Temporary C of O 5/3/2021 5/3/2021 05/03/2021
Misc
Corrective Action Required
05/03/2021
-FINAL GRADE AND SOD -SPLASH BLOCKS AT ALL DOWNSPOUT AND SUMP PUMP DISCHARGE LOCATIONS, MINIMUM 36" DISCHARGE FROM FOUNDATION -GUARDRAIL AT FRONT PORCH, MORE THAN 30" FROM GRADE -SEWER CLEANOUT AT FRONT OF LOT TO GRADE AND CAP CLEANOUT OK FOR TCO - TCO EXPIRES 5/21/21
Erosion Control Inspection Residential Passed 06/17/2021
DCM5 ESC INSP DENIED
Resolved
06/17/2021
Plot Plan Inspection Passed 6/17/2021 6/17/2021 06/17/2021
Occupancy Inspection - Codes Residential Temporary C of O 6/17/2021 6/17/2021 06/17/2021
Misc
Corrective Action Required
05/03/2021
-RESOLVE OUTSTANDING INSPECTION FEE(S) BEFORE FINAL C OF O OK FOR TCO - TCO EXPIRES 6/24/21
Occupancy Inspection - Codes Residential Full C of O 6/21/2021 6/21/2021 06/21/2021
Misc
Resolved
06/21/2021
Documents & Images
Date Uploaded File Type Document Name
07/21/2020 RR #64 - PERMIT APPLICATION
07/21/2020 LOT 64 FINAL
07/21/2020 400374
07/21/2020 RR #64 - Bristol Ridge - Craftsman - Sheets- signed
07/21/2020 RR #64 - TRUSS LAYOUT
07/27/2020 Receipt Receipt for transaction:2020-004704
07/27/2020 Letter DS Building Permit
07/27/2020 APPROVED 400374
07/27/2020 APPROVED LOT 64 FINAL
07/27/2020 APPROVED RR #64 - Bristol Ridge - Craftsman - Sheets- signed
07/27/2020 APPROVED RR #64 - TRUSS LAYOUT
08/13/2020 APPROVED REVISED 64 RESERVE AT STONEY CREEK 2ND FLOOR LAYOUT REVISED 8-7-20- signed
08/13/2020 APPROVED REVISED 64 RESERVE AT STONEY CREEK 1ST FLOOR LAYOUT REVISED 8-7-20- signed
08/13/2020 APPEOVED REVISED RR #64 - Bristol Ridge - Craftsman - Revision 8-7-20- signed
08/28/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
04/26/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter Codes Temporary Certificate of Occupancy
06/17/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter INSPECTION SUMMARY
06/17/2021 Letter Codes Temporary Certificate of Occupancy
06/18/2021 Receipt Receipt for transaction:2021-004655
06/21/2021 Letter Field Certificate of Occupancy
06/21/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home