Permit Application Status

PRRES20202000


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202000
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
07/20/2020
07/22/2020
06/09/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/22/2020 07/21/2020
Kim Brennan
Residential Plan Review Approved 07/22/2020 07/21/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,134.90 $1,134.90 Paid 07/21/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/21/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/21/2020
8331504-EFHB Middle Big Creek, Full $535.68 $535.68 Paid 07/21/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 07/21/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 07/21/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 07/21/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/14/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/14/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 05/14/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/15/2020 (2:15) 9/15/2020 09/15/2020
Erosion Control Inspection Residential Failed 10/8/2020 10/8/2020 10/08/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/08/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED AT FRONT OF LOT. CLEAN MUD AND GRAVEL AT STREET
Underslab Plumbing Inspection - Residential Failed 10/8/2020 10/8/2020 10/08/2020
Misc
Corrective Action Required
10/08/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED AT FRONT OF LOT. CLEAN MUD AND GRAVEL AT STREET
Underslab Plumbing Inspection - Residential Passed 10/12/2020 10/12/2020 10/12/2020
Misc
Resolved
10/12/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED AT FRONT OF LOT. CLEAN MUD AND GRAVEL AT STREET
Electrical Service Inspection Passed 1/8/2021 1/8/2021 01/08/2021
Gas Piping Inspection - Residential Passed 1/8/2021 1/8/2021 01/08/2021
Gas Service Inspection - Residential Failed 1/8/2021 1/8/2021 01/08/2021
Misc
Corrective Action Required
01/08/2021
-GAS PRESSURE AT 7 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 1/8/2021 1/8/2021 01/08/2021
Misc
Corrective Action Required
01/08/2021
-Joist hangers at header and sgl joist connection to header, over 4’, above dbl door garage -Seal DWV penetrations at top plate laundry -Nail truss H2.5 laundry -Flash/install windows -garage beam bears on (3) 2x6 per plans, bearing on (2) currently -security block exterior doors -Secure all DWV 2” or less at mid point -protection plates at refrigerator pex, master shower pex -structural straps at all top plates bored 50% or more, all interior load bearing walls and exterior walls -stud shoe at DWV master bath exterior wall, nail stud shoes already installed -Bocca protection plate at DWV master bath vanity top plate -Bocca protection plates at DWV, master shower top and bottom plates -protection plates on NM less than 1 1/4” from end of stud, master bed -EC#2 per plans -master bedroom -Remove lid at back patio to allow for inspection of truss H2.5 clips -Connect 2x6 to 2x4 top plates, 2nd floor stairs -Stud shoes required at DWV vanity bath#2, 2nd floor -Fireblock DWV floor penetrations behind bathtub bsth#2, 2nd floor -LIB bracing,all locations per plans -(2) 2x10 header at bedroom #4 door load bearing wall per plans, 2nd floor -Bedroom #4 ladder blocking per plans for 1st floor attic access -Properly support stair landing 2nd floor -Joist hanger at header connection above sump pump basement -basement stairs, (2) 2x10 at stringer with bearing on 3” SCH 40 steel column on pier pad “A” per plans -Nail sheathing per plans- 6” edge, 12” field
Sewer Service Inspection - R Passed 1/14/2021 (1:00) 1/14/2021 01/14/2021
Gas Service Inspection - Residential Passed 1/15/2021 1/15/2021 01/15/2021
Misc
Resolved
01/15/2021
All Rough Inspection - Residential Failed 1/15/2021 1/15/2021 01/15/2021
Misc
Corrective Action Required
01/08/2021
-Flash/install windows -garage beam bears on (3) 2x6 per plans, bearing on (2) ,currently (1) 2x6 cut short -terminate electrical at office wall -Bocca protection plate at DWV master bath vanity top plate -Bocca protection plates at DWV, master shower top and bottom plates,1st floor water closet at front -Remove lid at back patio to allow for inspection of truss H2.5 clips -Connect 2x6 to 2x4 top plates, 2nd floor stairs -seal unused penetration 2nd floor stair top plate -Fireblock DWV floor penetrations behind bathtub bsth#2, 2nd floor -(2) 2x10 header at bedroom #4 door load bearing wall per plans, 2nd floor -Bedroom #4 ladder blocking per plans for 1st floor attic access -Properly support stair landing 2nd floor -basement stairs, (2) 2x10 at stringer with bearing on 3” SCH 40 steel column on pier pad “A” per plans -Nail sheathing per plans- 6” edge, 12” field
Water Service Inspection - R Passed 1/19/2021 (10:45) 1/19/2021 01/19/2021
Driveway Inspection Partial 2/3/2021 (P.M.) 2/3/2021 02/03/2021
Misc
Informational
02/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Not Ready 1/25/2021 1/25/2021 02/10/2021
Misc
Corrective Action Required
01/15/2021
-Bocca protection plate at DWV master bath vanity top plate -Bocca protection plates at DWV, master shower top and bottom plates,1st floor water closet at front -Install structural screws at end of all trusses at covered patio -basement stairs, (2) 2x10 at stringer with bearing on 3” SCH 40 steel column on pier pad “A” per plans pier schedule -Nail sheathing per plans- 6” edge, 12” field *OK to Insulate*
All Rough Inspection - Residential Not Ready 2/8/2021 2/8/2021 02/10/2021
Misc
Corrective Action Required
01/25/2021
-Bocca protection plate at DWV master bath vanity top plate -Bocca protection plates at DWV,1st floor water closet at front -basement stairs, (2) 2x10 at stringer with bearing on 3” SCH 40 steel column on pier pad “A” per plans pier schedule -Nail sheathing per plans- 6” edge, 12” field-East side *OK to Insulate*
All Rough Inspection - Residential Not Ready 2/10/2021 2/10/2021 02/10/2021
Misc
Corrective Action Required
02/08/2021
-basement stairs, (2) 2x10 at stringer with bearing on 3” SCH 40 steel column on pier pad “A” per plans pier schedule Studs that were installed do not touch the 2-2x10's. install full length studs or install approved shims.
All Rough Inspection - Residential Not Ready 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
02/10/2021
-basement stairs, (2) 2x10 at stringer with bearing on 3” SCH 40 steel column on pier pad “A” per plans pier schedule Studs that were installed do not touch the 2-2x10's. install full length studs or install approved shims.
Driveway Inspection Passed 2/10/2021 2/10/2021 02/22/2021
Misc
Informational
02/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 4/20/2021 4/20/2021 04/20/2021
Misc
Corrective Action Required
02/11/2021
-basement stairs, (2) 2x10 at stringers per plans
All Rough Inspection - Residential Passed 5/4/2021 5/4/2021 05/04/2021
Misc
Resolved
05/04/2021
-basement stairs, (2) 2x10 at stringers per plans
Occupancy Inspection - Codes Residential Temporary C of O 5/7/2021 5/7/2021 05/07/2021
Misc
Corrective Action Required
05/07/2021
-Resolve outstanding inspection fee(s) before final c of o -Connect gutter downspout discharge at front near garage -Add splash block or extension to sump pump discharge, minimum 36" discharge from foundation -Remove all trash and debris storm inlet back of lot -Uncover and raise to grade if necessary manhole at north front of lot as shown on plot plan **OK FOR TCO - TCO EXPIRES 5/21/21**
Plot Plan Inspection Failed 5/7/2021 5/7/2021 05/07/2021
Misc
Corrective Action Required
05/07/2021
-LOCATE AND RAISE TO GRADE IF NECESSARY MANHOLE AT NORTH FRONT OF LOT AS SHOWN ON PLOT PLAN
Occupancy Inspection - Codes Residential Failed 5/17/2021 5/17/2021 05/17/2021
Misc
Corrective Action Required
05/07/2021
-Remove all trash and debris storm inlet back of lot -Uncover and raise to grade if necessary manhole at north front of lot as shown on plot plan **OK FOR TCO - TCO EXPIRES 5/21/21**
Occupancy Inspection - Codes Residential Failed 5/26/2021 5/26/2021 05/26/2021
Misc
Corrective Action Required
05/17/2021
-Remove all trash and debris from storm inlet back of lot **OK FOR TCO - TCO EXPIRES 5/21/21**
Plot Plan Inspection Passed 06/09/2021
Misc
Resolved
06/09/2021
Erosion Control Inspection Residential Passed 06/09/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/09/2021
Occupancy Inspection - Codes Residential Full C of O 6/9/2021 6/9/2021 06/09/2021
Misc
Resolved
06/09/2021
Documents & Images
Date Uploaded File Type Document Name
07/20/2020 Letter Permit Application and license tax form
07/21/2020 Plot Plan Approved Plot Plan
07/21/2020 Drawing Approved Drawings
07/21/2020 Drawing Approved Truss Layout
07/21/2020 Drawing Approved Truss Package
07/21/2020 Receipt Receipt for transaction:2020-004590
07/22/2020 Letter DS Building Permit
09/15/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
02/03/2021 Letter INSPECTION SUMMARY
02/08/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/11/2021 Letter INSPECTION SUMMARY
02/16/2021 Letter INSPECTION SUMMARY
02/16/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter INSPECTION SUMMARY
04/20/2021 Letter INSPECTION SUMMARY
05/04/2021 Letter INSPECTION SUMMARY
05/07/2021 Letter Codes Temporary Certificate of Occupancy
05/07/2021 Letter INSPECTION SUMMARY
05/14/2021 Receipt Receipt for transaction:2021-003012
05/17/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter Field Certificate of Occupancy
06/09/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home