Permit Application Status

PRRES20201863


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201863
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED DECK ROOF TRUSS PACKAGE
07/08/2020
07/13/2020
02/02/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/10/2020 07/10/2020
Steve Conrick
Residential Plan Review Approved 07/10/2020 07/10/2020
Steve Conrick
Planning Review (RES) Approved 07/10/2020 07/10/2020
Victoria Nelson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,415.09 $1,415.09 Paid 07/13/2020
Right of Way Permit Fee $80.00 $80.00 Paid 07/13/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/13/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/13/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 07/13/2020
Water Meter Fee $455.54 $455.54 Paid 07/13/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 01/21/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/3/2020 8/3/2020 08/03/2020
Sewer Service Inspection - R Passed 8/20/2020 (1:00) 8/20/2020 08/20/2020
Erosion Control Inspection Residential Failed 08/21/2020
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
08/21/2020
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
08/21/2020
- REPAIR DAMAGED SILT FENCE AT FRONT OF LOT
Underslab Plumbing Inspection - Residential Not Ready 8/21/2020 8/21/2020 08/21/2020
Misc
Corrective Action Required
08/21/2020
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
08/21/2020
REPAIR DAMAGED SILT FENCE AT FRONT OF LOT
Underslab Plumbing Inspection - Residential Passed 8/25/2020 8/25/2020 08/25/2020
Misc
Resolved
08/25/2020
Misc
Resolved
08/25/2020
Water Service Inspection - R Passed 8/27/2020 (1:00) 8/27/2020 08/27/2020
Gas Service Inspection - Residential Failed 11/5/2020 11/5/2020 11/05/2020
Miscellaneous Correction
Corrective Action Required
11/05/2020
-NO GAUGE PRESENT
Gas Piping Inspection - Residential Passed 11/5/2020 11/5/2020 11/05/2020
Electrical Service Inspection Passed 11/5/2020 11/5/2020 11/05/2020
All Rough Inspection - Residential Failed 11/5/2020 11/5/2020 11/05/2020
Miscellaneous Correction
Corrective Action Required
11/05/2020
**MAINTAIN GRAVEL FILTER** -PROVIDE 6” NAILING PATTERN AT BOTTOM EDGE OF EXTERIOR SHEATHING -BOLT OUTER PLY OF RIM TO LEDGER AT DECK AND ADD ANGEL CLIP TO INNER PLY -SUPPORT END JOIST AT WALL OFFEST AT DECK -PROVIDE (2) BOLTS PER POST/ RIM CONNECTION AT DECK -PROVIDE HANGERS ON STAIR HEADER -SEAL PLATE PENETRATION ABOVE 2 CAR GARAGE -PROVIDE H2.5 ON ALL HIP TRUSSES -PROVIDE APPROVED FIREBLOCKING IN ALL CHASES IN GARAGE AND DINING—FIBERGLASS INSULATION MUST FILL ENTIRE CAVITY AND BE 16” THICK TO BE USED AS FIREBLOCKING -SEAL GAPS IN FIREBLOCKING IN DEAD SPACES IN DINING AND LIVING ROOM -PROTECTION PLATE AT NM IN DUCT CHASE, IN WALL IN DINING, UNDER LIGHT SWITCH IN DINING/LIVING, ANDIN OWNER’S ENTRY CLOSET -NAIL DOUBLE 2X10 JOIST IN GREAT ROOM -ADDRESS OVER BORED JOIST IN GREAT ROOM -INSTALL H2.5 AT COVERED DECK DIRECTLY TO FRAMING -PROVIDE LIB AT ALL LOCATIONS FIRST AND SECOND FLOOR -MISSING (4) 2X4 UNDER LVL BEAM IN KITCHEN/ OWNER’S ENTRY -MISSING (3) 2X4 IN KITCHEN WALL -MISSING (3) 2X4 IN STAIRWELL BEARING WALL -MISSING (4) 2X4 IN GREAT ROOM WALL BY HVAC -ADD STUD UNDER GIRDER TRUSS IN BEARING WALL BED 2 -FIREBLOCK DEAD SPACE BETWEEN WALLS AT STAIRWELL -PROVIDE JOIST HANGERS AT STAIRWELL TRIMMER -TIGHTEN ANCHOR BOLTS IN BASEMENT -PROVIDE ANCHOR BOLTS WITHIN 12” OF PLATE BREAK AT WEST WALL NEAR DWV AND WEST WALL BY SW WINDOW -PROVIDE GAUGE FOR PRESSURE TEST ON GAS -SECURE GAS AT FIREPLACE
All Rough Inspection - Residential Failed 11/10/2020 11/10/2020 11/10/2020
Misc
Corrective Action Required
11/10/2020
-PROVIDE 6” NAILING PATTERN AT BOTTOM EDGE OF EXTERIOR SHEATHING -BOLT OUTER PLY OF RIM TO LEDGER AT DECK AND ADD ANGEL CLIP TO INNER PLY -SUPPORT END JOIST AT WALL OFFEST AT DECK -PROVIDE (2) BOLTS PER POST/ RIM CONNECTION AT DECK -PROVIDE HANGERS ON STAIR HEADER -PROVIDE H2.5 ON ALL HIP TRUSSES - GARAGE -ADD STUD UNDER GIRDER TRUSS IN BEARING WALL BED 2 -FIREBLOCK DEAD SPACE BETWEEN WALLS AT STAIRWELL -PROVIDE JOIST HANGERS AT STAIRWELL TRIMMER -PROVIDE ANCHOR BOLTS WITHIN 12” OF PLATE BREAK AT WEST WALL NEAR DWV -PROVIDE GAUGE FOR PRESSURE TEST ON GAS -SECURE GAS AT FIREPLACE OK TO INSULATE
All Rough Inspection - Residential Failed 11/12/2020 11/12/2020 11/12/2020
Miscellaneous Correction
Corrective Action Required
11/10/2020
-PROVIDE GAUGE FOR PRESSURE TEST ON GAS AND COMPLETE GAS LINE AT FURNACE OK TO ROCK
Driveway Inspection Passed 11/17/2020 (A.M.) 11/17/2020 11/17/2020
Misc
Informational
11/17/2020
On Tuesday, 11-17-2020. Performed Driveway inspection that met city spec’s. Driveway passed inspection.
Sidewalk Inspection Passed 11/17/2020 (A.M.) 11/17/2020 11/17/2020
Misc
Informational
11/17/2020
On Tuesday,11-17-2020. I performed and passed a sidewalk inspection that met city standards.
Gas Service Inspection - Residential Failed 11/19/2020 11/19/2020 11/19/2020
Miscellaneous Correction
Corrective Action Required
11/05/2020
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Passed 11/19/2020
Miscellaneous Correction
Resolved
11/19/2020
Gas Service Inspection - Residential Passed 11/23/2020 11/23/2020 11/23/2020
Miscellaneous Correction
Resolved
11/23/2020
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR 15 MINUTES
Occupancy Inspection - Codes Residential Failed 1/20/2021 1/20/2021 01/20/2021
Misc
Corrective Action Required
01/20/2021
-Resolve outstanding inspection fee(s) before final c of o -Complete final grade and sod -Obtain lawn irrigation system permit -dining room wall receptacles at wall trim, correct faceplates (no modification), max box setback 1/4” for non combustibles, no setback for combustibles -Cover plate at oven box, lockout required at breaker -Install security screws at back deck door and basement walkout -R303.7 Basement stairway lighting must have lighting control switch at top and bottom of stairway -breaker lockouts required on any hardwired appliances -AFCI protection required at washer circuit -Sump pump discharge minimum 36” from foundation
Plot Plan Inspection Failed 1/26/2021 1/26/2021 01/26/2021
Misc
Corrective Action Required
01/26/2021
-SLOPE GRADE PER PLOT PLAN, NEGATIVE SLOPE ON WEST SIDE OF HOUSE TOWARDS HOUSE -
Occupancy Inspection - Codes Residential Temporary C of O 1/26/2021 1/26/2021 01/26/2021
Misc
Corrective Action Required
01/20/2021
-WATER METER LID TO BE EVEN WITH GRADE, MAINTAIN 14”-18” DISTANCE BETWEEN TOP OF METER AND LID -SOD LESS THAN 6” FROM SIDING ON WEST SIDE OF HOUSE -SEE PLOT PLAN INSPECTION REPORT CONCERNING NEGATIVE SLOPE ON WEST SIDE OF HOUSE, GRADE PER PLOT PLAN OK FOR TCO - TCO EXPIRES 2/9/21
Plot Plan Inspection Passed 02/02/2021
Misc
Resolved
02/02/2021
-SLOPE GRADE PER PLOT PLAN, NEGATIVE SLOPE ON WEST SIDE OF HOUSE TOWARDS HOUSE -
Occupancy Inspection - Codes Residential Full C of O 2/2/2021 2/2/2021 02/02/2021
Misc
Resolved
02/02/2021
Documents & Images
Date Uploaded File Type Document Name
07/08/2020 HT #18 - PERMIT APPLICATION
07/08/2020 LOT 18 FINAL
07/08/2020 18 HAWTHORNE RIDGE TRUSS LAYOUT
07/08/2020 HT #18 - Charleston - Mediterranean - Sheets- signed
07/08/2020 400393
07/10/2020 HT #18 - Charleston - Mediterranean - Sheets- signed
07/10/2020 APPROVED 18 HAWTHORNE RIDGE TRUSS LAYOUT
07/10/2020 APPROVED 400393
07/10/2020 APPROVED HT #18 - Charleston - Mediterranean - Sheets- signed0
07/10/2020 APPROVED LOT 18 FINAL
07/13/2020 Receipt Receipt for transaction:2020-004347
07/13/2020 Receipt Receipt for transaction:2020-004348
07/13/2020 Letter DS Building Permit
07/21/2020 18 Hawthorne Ridge-Subgrade
08/03/2020 Lot 18 Hawthorne Ridge - Footing Inspection
08/03/2020 18 Hawthorne Ridge Subgrade Reinspection
08/03/2020 Letter INSPECTION SUMMARY
08/10/2020 Lot 18 Hawthorne Ridge wall
08/20/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
08/25/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/05/2020 Letter INSPECTION SUMMARY
11/10/2020 18 Hawthorne Ridge Floor Joists Holes Letter
11/10/2020 Letter INSPECTION SUMMARY
11/12/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
11/19/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/21/2021 Receipt Receipt for transaction:2021-000322
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter Codes Temporary Certificate of Occupancy
02/02/2021 Letter INSPECTION SUMMARY
02/02/2021 Letter Field Certificate of Occupancy
02/02/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents