Permit Application Status

PRRES20201729


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201729
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
06/25/2020
07/13/2020
05/10/2021
Locations
Contacts
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INHOME SYSTEMS LLC, Address:510 MISSION RD SW, Phone:(816) 372-0483  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
DROTHFUSS@CAPITALCONST.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 07/02/2020 07/13/2020
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
06/30/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provide the square footage for the unfinished basement
Plot Plan Review Approved 07/02/2020 07/08/2020
Kim Brennan
Property boundary
Corrective Action Required
06/30/2020

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. Please add the distance of 19.92' to the front of this lot and double check the distance of 119.44 that runs along the west side of the lot
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,274.46 $1,274.46 Paid 07/13/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 07/13/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 07/13/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 07/13/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 07/13/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 07/13/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/29/2020 (11:30) 7/29/2020 at 11:40 AM 07/29/2020
Underslab Plumbing Inspection - Residential Passed 8/12/2020 8/12/2020 at 7:45 AM 08/12/2020
Sewer Service Inspection - R Passed 8/26/2020 (10:30) 8/26/2020 08/26/2020
Water Service Inspection - R Passed 8/27/2020 (2:30) 8/27/2020 08/27/2020
Piers/Caissons Inspection - Residential Passed 9/21/2020 9/21/2020 09/21/2020
Miscellaneous Inspection Partial 9/21/2020 9/21/2020 09/21/2020
Informational
09/21/2020
**NAILING OF THE BRACE WALL IS OK; HOWEVER, INSTALL THE 2" ANCHOR WASHERS. CHECK THIS AT ROUGH-IN INSPECTION
Electrical Service Inspection Passed 10/14/2020 10/14/2020 10/14/2020
Gas Service Inspection - Residential Passed 10/14/2020 10/14/2020 10/14/2020
All Rough Inspection - Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Corrective Action Required
10/14/2020
FRAMING: -Install garage portal brace wall straps; install 2” washers -Nail corner studs with 16d@12” oc or equivalent nailing -Fb fireplace space from joist space -Solid block cantilevered joists above bearing wall -Provide 3 studs support for lvl beam at living rm angled wall -Install hanger support for trusses above rear dining -Block full width of hanger above cooktop -Provide full solid support for lvl beam point load inside return air space below closet near office -Have engineer address lvl beam with one ply break above office return air -Tempered glass window required at mid-stair landing -Some of the screws securing the trusses to the wall are installed too high near the top plate. -Fb master bathroom and laundry wall from roof -Provide solid support under rear dining I beam point load -Notched joist below half bathroom -Toe nail all joists to sill plates with 4-8d or 3-10d -Double every other joists under kitchen island ELECTRICAL: -Seal all penetrations of ceiling return air space -Protect oven wiring at bottom wall plate; home runs at front bedroom **DO NOT INSULATE
All Rough Inspection - Residential Failed 10/16/2020 10/16/2020 10/16/2020
Misc
Corrective Action Required
10/14/2020
-Solid block cantilevered joists above bearing wall **Insulate first, then block -Install hanger support for trusses above rear dining **Hammer the nails in -Have engineer address lvl beam with one ply break above office return air -Tempered glass window required at mid-stair landing -Notched joist below half bathroom **plumber needs to redo the plaumbing -Toe nail all joists to sill plates with 4-8d or 3-10d **Not all joists are nailed to sill plates. **OK TO INSULATE
All Rough Inspection - Residential Partial 10/22/2020 10/22/2020 10/22/2020
Misc
Corrective Action Required
10/16/2020
-Have engineer address lvl beam with one ply break above office return air -Tempered glass window required at mid-stair landing **OK TO ROCK PENDING APPROVAL FROM ENGINEER
All Rough Inspection - Residential Partial 10/22/2020 10/22/2020
Misc
Partial Correction
10/22/2020
-Tempered glass window required at mid-stair landing **OK TO ROCK
Driveway Inspection Partial 11/2/2020 11/02/2020
Misc
Informational
11/02/2020
Driveway - forms and materials passed pre-inspection.
Sidewalk Inspection Partial 11/2/2020 11/02/2020
Misc
Informational
11/02/2020
Sidewalk - forms and materials passed pre-inspection.
Sidewalk Inspection Passed 11/9/2020 11/9/2020 11/11/2020
Misc
Informational
11/02/2020
Sidewalk - forms and materials passed pre-inspection.
Misc
Informational
11/11/2020
Sidewalk - passed final inspection.
Driveway Inspection Passed 11/9/2020 11/9/2020 11/11/2020
Misc
Informational
11/02/2020
Driveway - forms and materials passed pre-inspection.
Misc
Informational
11/11/2020
Driveway - passed final inspection.
All Rough Inspection - Residential Passed 03/04/2021
Misc
Resolved
03/04/2021
-Tempered glass window required at mid-stair landing **OK TO ROCK
Occupancy Inspection - Codes Residential Failed 3/4/2021 3/4/2021 03/04/2021
Misc
Corrective Action Required
03/04/2021
-Obtain lawn irrigation permit and submit the backflow test report to city -Final grade, sod, gutters, downspout and sump pump extensions -Paint gas service piping -Garage: rock underneath boxed-out walls; extend duct chase to floor -Add another 3” screws at rear patio door for security -Kitchen countertop receptacle spacing not compliant -Provide gfci protection for hydro tub motor receptacle -Provide AFCI protection for all outlets required per NEC 210.12 (kitchen refrigerator) -Provide max 45 amp AC breaker
Occupancy Inspection - Codes Residential Full C of O 5/10/2021 5/10/2021 05/10/2021
Misc
Resolved
05/10/2021
-Sewer manhole at front is buried -Final grade, sod, gutters, downspout and sump pump extensions -Paint gas service piping -Garage: rock underneath boxed-out walls; extend duct chase to floor -Add another 3” screws at rear patio door for security -Kitchen countertop receptacle spacing not compliant -Provide gfci protection for hydro tub motor receptacle -Provide AFCI protection for all outlets required per NEC 210.12 (kitchen refrigerator) -Provide max 45 amp AC breaker
Documents & Images
Date Uploaded File Type Document Name
06/25/2020 Letter Permit Application and license tax form
06/30/2020 Letter Codes Residential Plan Review
07/08/2020 Plot Plan Approved Plot Plan
07/13/2020 Drawing Approved Drawings
07/13/2020 Receipt Receipt for transaction:2020-004419
07/13/2020 Letter DS Building Permit
07/29/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/16/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
05/10/2021 Letter Codes Final Certificate of Occupancy
05/10/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home