Permit Application Status

PRRES20201552


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201552
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
06/10/2020
06/11/2020
12/22/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/12/2020 06/11/2020
Kim Brennan
Drainage swales
Corrective Action Required
06/10/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
Basement opening elevations
Corrective Action Required
06/10/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. The RMBOE should be 1026.22 instead of 1026.27
As-graded plot plan
Corrective Action Required
06/10/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 06/12/2020 06/10/2020
Kim Brennan
Planning Review (RES) Approved 06/12/2020 06/10/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,281.08 $1,281.08 Paid 06/11/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/11/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 06/11/2020
Water Meter Fee $425.02 $425.02 Paid 06/11/2020
Right of Way Permit Fee $80.00 $80.00 Paid 06/11/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 7/7/2020 7/7/2020 07/07/2020
Misc
Corrective Action Required
07/07/2020
- Interior drain tile cut short, extend interior drain tile to opposite end of foundation footing from sump.
Footing Inspection - Residential Passed 6/18/2020 6/18/2020 07/07/2020
Underslab Plumbing Inspection - Residential Passed 7/8/2020 7/8/2020 07/08/2020
Misc
Resolved
07/08/2020
All Rough Inspection - Residential Failed 9/3/2020 9/3/2020 09/03/2020
Misc
Corrective Action Required
09/03/2020
GENERAL -anchor steel columns FRAMING -Anchor bolts required within 12” bottom plate ends & splice -tighten anchor bolts -missing truss strap in garage -fireblock all furr outs -fireblock at tub traps -properly support and .... garage ceiling furr out -Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” oc per code -complete furr our- mechanical in living room -Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge at exterior doors -fireblock mechanical top plate penetration in dining room -properly nail truss hangers in garage -truss hangers per plans -ensure all to and bottom plates are fireblocked ELECTRICAL -relocate light boxes in garage for framing furr downs where necessary -conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. MECHANICAL -B vent requires minimum 1” clearance to combustibles GAS Pressure test required
Electrical Service Inspection Passed 9/3/2020 9/3/2020 09/03/2020
Gas Piping Inspection - Residential Failed 9/3/2020 9/3/2020 09/03/2020
Misc
Corrective Action Required
09/03/2020
Pressure test required
Gas Service Inspection - Residential Failed 9/3/2020 9/3/2020 09/03/2020
Gas Piping Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/03/2020
9/8 - Unable to check inspection items in basement due to standing water, pump out water and reschedule when dry - Complete gas line installation at fireplace - Gas pressure test required
Gas Service Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
9/8 - Unable to check inspection items in basement due to standing water, pump out water and reschedule when dry - Complete gas line installation at fireplace - Gas pressure test required
All Rough Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
9/8 - Unable to check inspection items in basement due to standing water, pump out water and reschedule when dry GENERAL -anchor steel columns FRAMING -missing H2.5 truss strap in garage -fireblock all furr outs garage, fireblock all vertical to horizontal - Fireblock HVAC and DWV chase in living room and Fireblock vertical to horizontal - Fireblock deadspace at kitchen entrance from garage -properly support and size members at garage ceiling furr out to support ceiling load -truss hangers per plans -ensure all to and bottom plates are Fireblocked ELECTRICAL -conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. MECHANICAL -B vent requires minimum 1” clearance to combustibles GAS - Complete gas line installation at fireplace - Gas Pressure test required
Gas Piping Inspection - Residential Passed 9/9/2020 9/9/2020 09/09/2020
Misc
Resolved
09/09/2020
Gas Service Inspection - Residential Failed 9/9/2020 9/9/2020 09/09/2020
Misc
Corrective Action Required
09/08/2020
- Gas pressure at 9 psi, minimum 10 psi hold for 15 minutes
All Rough Inspection - Residential Failed 9/9/2020 9/9/2020 09/09/2020
Misc
Corrective Action Required
09/08/2020
-anchor all steel columns in basement to floor -missing H2.5 truss strap in garage -fireblock all furr outs in garage - Fireblock deadspace at kitchen entrance from garage -Properly size studs at garage ceiling furr out and support 2x4 laid flat to floor joists above to properly support ceiling load -truss hangers per plans -conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. -B vent requires minimum 1” clearance to combustibles
Gas Service Inspection - Residential Passed 9/10/2020 9/10/2020 09/10/2020
Misc
Resolved
09/10/2020
All Rough Inspection - Residential Passed 9/10/2020 9/10/2020 09/10/2020
Misc
Resolved
09/10/2020
Sewer Service Inspection - R Passed 11/9/2020 (1:00) 11/9/2020 11/09/2020
Water Service Inspection - R Passed 11/11/2020 (1:00) 11/11/2020 11/11/2020
Driveway Inspection Passed 11/17/2020 (A.M.) 11/17/2020 11/17/2020
Misc
Informational
11/17/2020
On Tuesday, 11-17-2020. I performed and passed a driveway inspection that met city standard.
Sidewalk Inspection Passed 11/17/2020 (A.M.) 11/17/2020 11/17/2020
Misc
Informational
11/17/2020
On Tuesday, 11-17-2020. I performed and passed a sidewalk inspection that met city standard.
Piers/Caissons Inspection - Residential Passed 11/20/2020
Occupancy Inspection - Codes Residential Failed 11/20/2020 11/20/2020 11/20/2020
Misc
Corrective Action Required
11/20/2020
-Submit as graded plot plan for review -Complete final grade and sod -Place splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Remove all construction debris -Guardrail required at front porch, more than 30” from grade -security screws at doors -cover exposed NM at range exhaust -Remove all paint covers from smokes -Egress ladder required at basement egress window -Complete vanity lights 2nd floor bath
Occupancy Inspection - Codes Residential Temporary C of O 12/7/2020 12/7/2020 12/07/2020
Misc
Corrective Action Required
11/20/2020
-Complete final grade and sod -Place splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -See plot plan inspection report, correct grade at swale and clean debris/rocks from swale behind lot OK FOR TCO - TCO EXPIRES 12/21/20
Plot Plan Inspection Failed 12/7/2020 12/07/2020
Misc
Corrective Action Required
12/07/2020
- CORRECT GRADE AT SWALE, REMOVE ROCKS/DEBRIS FROM SWALE BACK OF LOT
Plot Plan Inspection Passed 12/22/2020 12/22/2020 12/22/2020
Misc
Resolved
12/22/2020
Occupancy Inspection - Codes Residential Full C of O 12/22/2020 12/22/2020 12/22/2020
Misc
Resolved
12/22/2020
Documents & Images
Date Uploaded File Type Document Name
06/10/2020 Letter Permit Application and license tax form
06/10/2020 Plans Approved Drawings
06/10/2020 Plans Approved Truss Package
06/10/2020 Plans Approved Truss Layout
06/10/2020 Letter Codes Residential Plan Review
06/11/2020 Plot Plan Approved Plot Plan
06/11/2020 Receipt Receipt for transaction:2020-002935
06/11/2020 Letter DS Building Permit
06/16/2020 Letter 35 Hawthorne Ridge Footing Location Letter
06/18/2020 Letter Lot 35 Hawthorne Ridge -Footing Inspection
06/25/2020 Letter Lot 35 Hawthorne Ridge Wall Inspection
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/03/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/09/2020 Letter INSPECTION SUMMARY
09/09/2020 Letter INSPECTION SUMMARY
09/09/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
11/09/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
12/04/2020 Plot Plan As Graded Plot Plan
12/07/2020 Letter Codes Temporary Certificate of Occupancy
12/07/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter Field Certificate of Occupancy
12/22/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home