Summary
PRRES20201526
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
06/08/2020
06/18/2020
03/04/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 06/11/2020 06/09/2020
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
06/09/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No smoke detector shown in the unfinished basement
Plot Plan Review Approved 06/11/2020 06/09/2020
Kim Brennan
Planning Review (RES) Approved 06/11/2020 06/09/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $988.83 $988.83 Paid 06/18/2020
Right of Way Permit Fee $80.00 $80.00 Paid 06/18/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/18/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/18/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 06/18/2020
Water Meter Fee $425.02 $425.02 Paid 06/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 7/29/2020 7/29/2020 07/29/2020
All Rough Inspection - Residential Failed 10/7/2020 10/7/2020 10/07/2020
Misc
Corrective Action Required
10/07/2020
-H2.5 truss straps missing - garage, laundry, mud room, stairway -Anchor bolt nut missing garage -Structural straps at top plates all exterior walls and interior load bearing walls bored 50% or more -furred our at b vent be master bed entrance and Fireblock -Protection plate at refrigerator pex in kitchen -Truss hangers per plans -Fireblock deadspace laundry -Color code/label grounding electrode conductor -Shield main service panel from pex water line,DWV above -Joist hangers required at joist to header connection for b vent, over 4’ -conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. -Joist hangers at floor joist connection to dbl header joists above basement stairs, over 4’
Electrical Service Inspection Failed 10/7/2020 10/7/2020 10/07/2020
Misc
Corrective Action Required
10/07/2020
-Color code/label grounding electrode conductor
Gas Piping Inspection - Residential Passed 10/7/2020 10/7/2020 10/07/2020
Gas Service Inspection - Residential Failed 10/7/2020 10/7/2020 10/07/2020
Misc
Corrective Action Required
10/07/2020
-Gas pressure at 2 PSI, must maintain 10 PSI for 15 minutes
Electrical Service Inspection Passed 10/13/2020 10/13/2020 10/13/2020
Misc
Corrective Action Required
10/07/2020
-Color code/label grounding electrode conductor
Gas Service Inspection - Residential Passed 10/13/2020 10/13/2020 10/13/2020
Misc
Corrective Action Required
10/07/2020
-Gas pressure at 2 PSI, must maintain 10 PSI for 15 minutes
All Rough Inspection - Residential Failed 10/13/2020 10/13/2020 10/13/2020
Miscellaneous Correction
Corrective Action Required
10/13/2020
-Truss hangers per plans- missing at truss J1 in dining room -Missing/ bent nails in truss hangers in garage -Seal fire block in deadspace at laundry
All Rough Inspection - Residential Passed 10/14/2020 10/14/2020 10/14/2020
Misc
Resolved
10/14/2020
Driveway Inspection Passed 10/19/2020 (P.M.) 10/19/2020 10/19/2020
Misc
Informational
10/19/2020
On Monday, 10-19-2020. I performed a driveway inspection that passed city standards.
Sidewalk Inspection Passed 10/19/2020 (P.M.) 10/19/2020 10/19/2020
Misc
Informational
10/19/2020
I performed a sidewalk inspection on Monday, 10-19-2020 that passed city standards.
Sewer Service Inspection - R Passed 11/10/2020 11/10/2020
Water Service Inspection - R Passed 11/11/2020 (1:00) 11/11/2020 11/11/2020
Footing Inspection - Residential Passed 12/23/2020
Piers/Caissons Inspection - Residential Passed 12/23/2020
Occupancy Inspection - Codes Residential Failed 12/23/2020 12/23/2020 12/23/2020
Misc
Corrective Action Required
12/23/2020
-Remove trash and construction debris from site -Final grade and sod per approved plot -Maintain minimum 6” of fall 10’ from foundation -Maintain erosion control until sod is in place -Remove debris from street, curb/gutter, sidewalk and stormwater box inlet -Downspouts and sump piping to discharge minimum 36” from foundation -Ensure all downspouts are properly secured -Identify white insulated conductor used as current carrying Conductor in panel and disconnect, Condensing unit circuit -Remove covers from smoke/carbon monoxide alarms -Locate and expose connection to concrete encased electrode
Plot Plan Inspection Passed 12/30/2020 12/30/2020
Occupancy Inspection - Codes Residential Temporary C of O 1/21/2021 1/21/2021 01/21/2021
Misc
Corrective Action Required
12/23/2020
*TCO UNTIL 3-15-21 -Final grade and sod per approved plot -Maintain minimum 6” of fall 10’ from foundation -Maintain erosion control until sod is in place
Occupancy Inspection - Codes Residential Full C of O 3/4/2021 3/4/2021 03/04/2021
Misc
Resolved
03/04/2021
Documents & Images
Date Uploaded File Type Document Name
06/08/2020 Letter Permit Application and license tax form
06/09/2020 Plans Approved Truss Layout
06/09/2020 Plans Approved Truss Package
06/09/2020 Letter Codes Residential Plan Review
06/09/2020 Plans Approved Drawings
06/09/2020 Plot Plan Approved Plot Plan
06/18/2020 Receipt Receipt for transaction:2020-003191
06/18/2020 Letter DS Building Permit
06/24/2020 Letter 39 Hawthorne Ridge-Subgrade
06/29/2020 Letter Lot 39 Hawthorne Ridge Footing Inspection
07/14/2020 Lot 39 Hawthorne Ridge Wall Inspection
07/29/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/23/2020 Letter INSPECTION SUMMARY
12/28/2020 LOT 39 ASBUILT (002)
12/29/2020 Plot Plan As Graded Plot Plan
12/30/2020 Letter INSPECTION SUMMARY
01/21/2021 Letter Codes Temporary Certificate of Occupancy
01/21/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter Field Certificate of Occupancy
03/04/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home