Permit Application Status

PRRES20201354


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201354
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - TRUSS PACKAGE - FINISHED BASEMENT
05/27/2020
06/02/2020
01/04/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 06/02/2020 06/02/2020
Dylan Eppert
Plot Plan Review Approved 05/29/2020 06/01/2020
Dylan Eppert
Residential Plan Review Approved 05/29/2020 05/29/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $822.50 $822.50 Paid 06/02/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 06/02/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 06/02/2020
Water Meter Fee $425.02 $425.02 Paid 06/02/2020
Right of Way Permit Fee $80.00 $80.00 Paid 06/02/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/02/2020
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 7/7/2020 7/7/2020 07/07/2020
Misc
Corrective Action Required
07/07/2020
NO INSPECTION PERFORMED - POST ADDRESS -
Footing Inspection - Residential Passed 07/07/2020
Underslab Plumbing Inspection - Residential Passed 7/8/2020 7/8/2020 07/08/2020
Misc
Corrective Action Required
07/07/2020
NO INSPECTION PERFORMED - POST ADDRESS -
Sewer Service Inspection - R Passed 8/21/2020 (1:00) 8/21/2020 08/21/2020
Water Service Inspection - R Passed 9/1/2020 (10:15) 9/1/2020 09/01/2020
Electrical Service Inspection Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
- Color code/label grounding electrode conductor
Gas Piping Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
- complete fireplace gas line install - Complete gas line installation, no gas line present - Gas Pressure test required
Gas Service Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
- complete fireplace gas line install - Complete gas line installation, no gas line present - Gas Pressure test required
All Rough Inspection - Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
- Clean mud/gravel at front of lot in street and maintain gravel filter - address before rescheduling any further inspections - Staple plans together in order - B vent - 1” clearance to combustible material required - strap top plate corner at master closet N wall - Structural straps required at top plates bored 50% or more on exterior walls and interior bearing walls - Seal all top plate penetrations - Fireblock deadspace between walls in kitchen - Fireblock unused bore in floor at 1st floor shower - EC#2 per plans - Protection plate required at DWV master closet - Anchor all columns to floor - Fireblock between top plate and foundation wall in basement - Fireblock vertical to horizontal at furred downs in basement - Attach EC#2 to framing in bedroom #3, rec room in basement - Fireblock deadspace between wall framing top plate bedroom #3 - Floor joist bored less than 2” from end of framing member for sump pump discharge line in basement - conductors stapled to bottom of floor joists in unfinished basement shall be run either through bored holes in joists or on running boards. - Color code/label grounding electrode conductor - No deck pier inspection performed - submit engineer report - Nail off joist hangers at deck - complete fireplace gas line install - Complete gas line installation, no gas line present
Erosion Control Inspection Residential Failed 09/08/2020
Misc
Corrective Action Required
09/08/2020
- Clean mud/gravel at front of lot in street and maintain gravel filter - address before rescheduling any further inspections
Electrical Service Inspection Passed 9/10/2020 9/10/2020 09/10/2020
Misc
Resolved
09/10/2020
Gas Piping Inspection - Residential Passed 9/10/2020 9/10/2020 09/10/2020
Misc
Resolved
09/10/2020
Gas Service Inspection - Residential Passed 9/10/2020 9/10/2020 09/10/2020
Misc
Resolved
09/10/2020
All Rough Inspection - Residential Passed 9/10/2020 9/10/2020 09/10/2020
Misc
Resolved
09/10/2020
Driveway Inspection Passed 10/1/2020 (P.M.) 10/1/2020 10/01/2020
Misc
Informational
10/01/2020
On Thursday, 10-01-2020. I performed a curb and driveway inspection and found sub grade and forming ready and passing inspection to pour.
Occupancy Inspection - Codes Residential Failed 12/9/2020 12/9/2020 12/09/2020
Misc
Corrective Action Required
09/10/2020
- No deck pier inspection performed - submit engineer report - Nail off joist hangers at deck
Miscellaneous Correction
Corrective Action Required
12/09/2020
No Deck pier inspection on record Sod splash blocks Repair drywall light switch garage near self closing door Nail joist hanger deck Sump pump discharge 36" from foundation Secure whip at A/C condenser Plans call for full height Continuous 6x6 cedar post at covered deck
Occupancy Inspection - Codes Residential Temporary C of O 12/31/2020 12/31/2020 12/31/2020
Misc
Corrective Action Required
12/09/2020
UNCOVER MANHOLE MH1-5 AS SHOWN ON PLOT PLAN OK FOR TCO - TCO EXPIRES 1-14-21
Miscellaneous Correction
Resolved
12/31/2020
Plot Plan Inspection Failed 12/31/2020 12/31/2020 12/31/2020
Misc
Corrective Action Required
12/31/2020
UNCOVER MANHOLE MH1-5 AS SHOWN ON PLOT PLAN
Plot Plan Inspection Passed 01/04/2021
Misc
Resolved
01/04/2021
Occupancy Inspection - Codes Residential Full C of O 1/4/2021 1/4/2021 01/04/2021
Misc
Resolved
01/04/2021
Documents & Images
Date Uploaded File Type Document Name
05/27/2020 Application Form H3 #4 - PERMIT APPLICATION
05/27/2020 4 Hawthorne Ridge Roof Layout- signed
05/27/2020 H3 #04 - Langston - Craftsman - Sheets- signed
05/27/2020 LOT 4 FINAL
05/27/2020 400156
05/29/2020 Specifications APPROVED TRUSS PACKAGE
05/29/2020 Drawing APPROVED TRUSS LAYOUT
05/29/2020 Plans APPROVED HOUSE PLANS
06/01/2020 Plot Plan APPROVED PLOT PLAN
06/02/2020 Plans Approved Elevations
06/02/2020 Receipt Receipt for transaction:2020-002570
06/02/2020 Letter DS Building Permit
06/15/2020 Letter Lot 4 Hawthorne Ridge -Footing Inspection
07/07/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter INSPECTION SUMMARY
09/01/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
09/10/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
12/29/2020 4 Hawthorne Ridge Non-continuous deck post letter
12/31/2020 Letter INSPECTION SUMMARY
12/31/2020 Letter Codes Temporary Certificate of Occupancy
12/31/2020 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/04/2021 Letter Field Certificate of Occupancy
01/04/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home