Summary
PRRES20201068
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
04/28/2020
05/07/2020
05/18/2021
Locations
Contacts
ROBERTSON REMODELING LLC, Address:500 James Rollo Dr, Phone:(816) 506-4090  
JASONFW1@COMCAST.NET  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
R-MECH HEATING COOLING PLUMBING/RHODES HEATING COOLING PLUMBING AND ROOTER, Address:1425 AGNES AVE, Phone:(816) 920-5955  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/06/2020 05/06/2020
Steve Conrick
Residential Plan Review Approved 05/06/2020 05/06/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,116.16 $1,116.16 Paid 05/06/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/06/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 05/06/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 05/06/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 05/06/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 05/06/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/20/2020 (1:00) 5/20/2020 05/20/2020
Erosion Control Inspection Residential Failed 06/09/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/09/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/09/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 6/9/2020 6/9/2020 06/09/2020
Sewer Service Inspection - R Passed 6/9/2020 (11:00) 6/9/2020 at 11:59 AM 06/09/2020
Misc
Informational
06/09/2020
- SEWER TRACER WIRE IN PLACE -
Water Service Inspection - R Partial 6/9/2020 at 11:58 AM 06/09/2020
Water Service Inspection - R Passed 6/10/2020 (8:45) 6/10/2020 06/10/2020
Electrical Service Inspection Passed 8/19/2020 8/19/2020 08/19/2020
Gas Service Inspection - Residential Failed 8/19/2020 8/19/2020 08/19/2020
Miscellaneous Correction
Corrective Action Required
08/19/2020
-INSTALL FIREPLACE
All Rough Inspection - Residential Failed 8/19/2020 8/19/2020 08/19/2020
Misc
Corrective Action Required
08/19/2020
-POST CLEAR ADDRESS -NAIL EXTERIOR SHEATHING PER PLANS -PROVIDE COLLAR TIES 48” OC IN GARAGE -CORRECT OVER NOTCHED STUDS IN GARAGE -REPLACE PORTAL FAME STUDS IN GARAGE CUT SHORT -PROTECT NM IN ATTIC BY ACCESS -PROVIDE (6) STUDS AT BEAM IN GARAGE PER PLAN -ADDRESS RAFTERS IN GARAGE NOT LANDING ON PLATES -INSTALL MISSING ROOF VENTS -INSTALL FIREPLACE -FIREBLOCK DEAD SPACE AT FIREPLACE -SECURE GAS LINE AT FIREPLACE -SEAL HOLE IN SUB FLOOR AT GARAGE ENTRY -ADDRESS RAFTERS AND HIP LANDING ON MULTIPLE BLOCKS THROUGHOUT -STRAP TOP PLATE AT KITCHEN WALL WHERE PLATE OVERLAP IS LESS THAN 24” -SECURE NM IN BED 2 OVER WINDOW -ADDRESS SPLIT OUT HIP IN MASTER -SEAL GAPS BETWEEN FLOORS IN MASTER SHOWER -PROVIDE (3) BEARING STUDS AT ENTRY PER PLAN -ALL 2X6 WALLS TO HAVE DOUBLE KING STUDS -PROVIDE (6) 2X4 AT LVL ENTRY PER PLAN -PROVIDE COLLAR TIES 48” OC OVER COVERED DECK -PROVIDE SOLID BLOCKING ABOVE BEAMS IN BASEMENT -FIRE BLOCK BEAMN WEBS IN FINISHED WALLS-FIRE BLOCK WEB AT BEAM WRAP AT SOUTH FUROUT WALL -PROVIDE CLIPS AND THRUST BLOCK CONNECTIONS ON STRINGERS PER PLANS
Gas Service Inspection - Residential Passed 8/31/2020 8/31/2020 08/31/2020
Miscellaneous Correction
Resolved
08/31/2020
-INSTALL FIREPLACE
All Rough Inspection - Residential Failed 8/31/2020 8/31/2020 08/31/2020
Miscellaneous Correction
Corrective Action Required
08/31/2020
-MAINTAIN GRAVEL FILTER -PROVIDE MINIMUM 1” CLEARANCE TO COMBUSTIBLES AT FIRE PLACE VENT -ADDRESS RAFTERS IN GARAGE NOT LANDING ON PLATES—MINIMUM 1 1/2” BEARING REQUIRED RAFTERS SUPPORTING VALLEY -SEAL EXTERIOR AT FIREPLACE -ADDRESS RAFTERS AND HIP LANDING ON MULTIPLE BLOCKS THROUGHOUT-ENGINEERED CORRECTION REQUIRED -ADDRESS SPLIT OUT HIP IN MASTER-ENGINEERED CORRECTION REQUIRED -ALL 2X6 WALLS TO HAVE DOUBLE KING STUDS -PROVIDE SOLID BLOCKING ABOVE BEAMS IN BASEMENT-MECHANICAL ROOM -PROVIDE THRUST BLOCK ON STRINGERS PER PLANS-
All Rough Inspection - Residential Passed 9/4/2020 9/4/2020 09/04/2020
Miscellaneous Correction
Corrective Action Required
08/31/2020
-MAINTAIN GRAVEL FILTER
Erosion Control Inspection Residential Failed 09/16/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
09/16/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2020
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN MUD AND DEBRIS FROM STREETS
Driveway Inspection Passed 10/2/2020 (P.M.) 10/2/2020 10/08/2020
Misc
Informational
10/08/2020
On Thursday, 10-08-2020. I performed a drive approach inspection and passed the inspection
Sidewalk Inspection Passed 10/8/2020 (P.M.) 10/8/2020 10/08/2020
Misc
Informational
10/08/2020
On Thursday, 10-08-2020. I performed a sidewalk inspection and inspection passed.
Erosion Control Inspection Residential Passed 10/09/2020
Misc
Resolved
10/09/2020
-Deficient erosion control, must be in compliance within two days or stop or order will be issued. Erosion control front of house requires maintenance -Remove debris from Street and curb/gutter immediately -Maintain gravel filter at driveway -Remove overgrown weeds and vegetation
Occupancy Inspection - Codes Residential Failed 1/7/2021 01/07/2021
Misc
Corrective Action Required
01/07/2021
-Remove trash and construction debris -Remove debris from street and sidewalk -Maintain erosion control methods until sod is in place -Final grade and sod per approved plot -Downspouts and sump piping to discharge minimum 36 inches from foundation -Seal all exterior penetrations . -Seal top insides of AC disconnect and electric meter enclosures. -door from garage to pantry required to self close and latch, also install door hardware . -remove paint covers from smoke/carbon alarms. -Complete lighting fixture installation, basement bathroom. -Exterior lighting fixtures at front man door require light source that is not readily accessible where below 8’ AFF. -All main or front entry doors to dwelling units shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. The view may be provided by a door viewer having a field of view of not less than one hundred eighty (180) degrees, by window(s), or by view port(s).
Occupancy Inspection - Codes Residential Temporary C of O 1/13/2021 1/13/2021 01/13/2021
Misc
Corrective Action Required
01/07/2021
-Final grade and sod per approved plot -Downspouts and sump piping to discharge minimum 36 inches from foundation TCO VALID THROUGH 02/13/21
Erosion Control Inspection Residential Passed 05/18/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/18/2021
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN MUD AND DEBRIS FROM STREETS
Piers/Caissons Inspection - Residential Passed 05/18/2021
Plot Plan Inspection Passed 05/18/2021
Occupancy Inspection - Codes Residential Full C of O 05/18/2021
Misc
Resolved
05/18/2021
-Final grade and sod per approved plot -Downspouts and sump piping to discharge minimum 36 inches from foundation TCO VALID THROUGH 02/13/21
Documents & Images
Date Uploaded File Type Document Name
04/28/2020 Permit application
05/01/2020 WWS008 Spec - Sealed Plans (March 2, 2020) (3)
05/01/2020 LOT 8 FINAL survey
05/06/2020 APPROVED WWS008 Spec - Sealed Plans (March 2, 2020) (3)
05/06/2020 APPROVED LOT 8 FINAL survey
05/06/2020 Receipt Receipt for transaction: 2020-001927
05/07/2020 Letter DS Building Permit
05/20/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
07/17/2020 Engineer Report/Study Final_2020.07.14_DPier_LSMO_Pat Cochran Concrete
08/19/2020 Letter INSPECTION SUMMARY
08/19/2020 Letter INSPECTION SUMMARY
08/19/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
09/04/2020 1909 River Run Drive - Structural Letter (September 3, 2020)
09/04/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
10/09/2020 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter Codes Temporary Certificate of Occupancy
01/13/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter INSPECTION SUMMARY
05/18/2021 Letter Codes Final Certificate of Occupancy
05/18/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home