Summary
PRRES20201001
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE - UNFINISHED BASEMENT - COVERED PATIO
04/21/2020
04/28/2020
12/09/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/24/2020 04/28/2020
Dylan Eppert
Deck location
Corrective Action Required
04/23/2020

Deck location, with dimensions to property lines must be provided on the plot plan. COVERED PATIO EXTENDS PAST THE 20' REAR YARD SETBACK AND MUST BE REVISED.
Residential Plan Review Approved 04/24/2020 04/23/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,669.59 $1,669.59 Paid 04/28/2020
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 04/28/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 04/28/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 04/28/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 04/28/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/28/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/28/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/22/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/22/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/11/2020 (1:30) 5/11/2020 05/11/2020
Underslab Plumbing Inspection - Residential Failed 6/1/2020 6/1/2020 06/01/2020
R405 FOUNDATION DRAINAGE
Corrective Action Required
06/01/2020
-DRAIN TILE NOT INSTALLED
Underslab Plumbing Inspection - Residential Not Ready 6/2/2020 6/2/2020 06/02/2020
R405 FOUNDATION DRAINAGE
Corrective Action Required
06/01/2020
-DRAIN TILE NOT INSTALLED, 6/2 INTERIOR DRAIN TILE STILL NOT INSTALLED - MUD WATER COVERING DWV BY CLEANOUT, UNABLE TO INSPECT CONNECTIONS THAT ARE COVERED, PUMP OUT WATER OR WAIT UNTIL CONDITIONS ALLOW FOR COMPLETE INSPECTION BEFORE RESCHEDULING
Underslab Plumbing Inspection - Residential Failed 6/4/2020 6/4/2020 06/04/2020
R405 FOUNDATION DRAINAGE
Corrective Action Required
06/02/2020
- MUD WATER COVERING DWV BY CLEANOUT, UNABLE TO INSPECT CONNECTIONS THAT ARE COVERED, PUMP OUT WATER OR WAIT UNTIL CONDITIONS ALLOW FOR COMPLETE INSPECTION BEFORE RESCHEDULING - INTERIOR DRAIN TILE HAS BEEN INSTALLED BUT IS DROPPPED ACROSS THE MIDDLE OF BASEMENT, LAY DRAIN TILE OUT ALONG FOOTING AND AT OPPOSITE FOUNDATION FOOTING CORNER FROM SUMP PUMP
Underslab Plumbing Inspection - Residential Passed 6/5/2020 6/5/2020 06/05/2020
R405 FOUNDATION DRAINAGE
Resolved
06/05/2020
Piers/Caissons Inspection - Residential Passed 6/8/2020 6/8/2020 06/08/2020
All Rough Inspection - Residential Not Ready 7/27/2020 7/27/2020 07/27/2020
Misc
Corrective Action Required
07/27/2020
NO INSPECTION PERFORMED - BASEMENT UNACCESSIBLE DUE TO STANDING WATER, RESCHEDULE WHEN DRY -
Electrical Service Inspection Failed 7/29/2020 7/29/2020 07/29/2020
Misc
Corrective Action Required
07/29/2020
- UFER GROUND REQUIRED
Gas Piping Inspection - Residential Passed 7/29/2020 7/29/2020 07/29/2020
Gas Service Inspection - Residential Passed 7/29/2020 7/29/2020 07/29/2020
All Rough Inspection - Residential Failed 7/29/2020 7/29/2020 07/29/2020
Misc
Corrective Action Required
07/27/2020
- Garage PFH per plans - Exterior garage portal strap nails missed interior framing - Fireblock DWV furred out garage - Fireblock vertical to horizontal at furred down for DWV and HVAC in garage and seal all gaps - Fireblock all tub/shower traps - Seal all top plate penetrations - NM penetration at 1st/2nd floor stairway - Fireblock all chases and dead spaces - Fireblock all furred downs vertical to horizontal - Support DWV ever 48” o.c. , traps are not considered support - (3) 2x4 at corner HVAC to dining room framing per plans - Truss hangers per plans - EC#2 per plans - Connect top plates at top stair landing at 2x6 to 2x4 wall - Anchor all columns to floor in basement - UFER ground required - 3” steel column at stairs missing in basement, pier location “A”
All Rough Inspection - Residential Failed 7/31/2020 7/31/2020 07/31/2020
Misc
Corrective Action Required
07/29/2020
- Garage PFH per plans - Exterior garage portal strap nails missed interior framing - Fireblock vertical to horizontal at furred down for DWV and HVAC in garage - (3) 2x4 at corner HVAC to dining room framing per plans - Truss hangers per plans - EC#2 per plans - Connect top plates at top stair landing at 2x6 to 2x4 wall - Anchor all columns to floor in basement - UFER ground required - 3” steel column at stairs missing in basement, pier location “A”
All Rough Inspection - Residential Failed 8/4/2020 8/4/2020 08/04/2020
Misc
Corrective Action Required
07/31/2020
- Garage PFH per plans - bolts, nuts, washers missing - (3) 2x4 at corner HVAC to dining room framing per plans - Truss hangers per plans - EC#2 per plans - Connect top plates at top stair landing at 2x6 to 2x4 wall - Anchor all columns to floor in basement - UFER ground required - 3” steel column at stairs missing in basement, pier location “A”
All Rough Inspection - Residential Failed 8/7/2020 8/7/2020 08/07/2020
Misc
Corrective Action Required
08/04/2020
- Garage PFH per plans - bolts, nuts, washers missing - (3) 2x4 at corner HVAC to dining room framing per plans - continuous framing member - Truss hangers per plans - EC#2 per plans - UFER ground required
All Rough Inspection - Residential Failed 8/10/2020 8/10/2020 08/10/2020
Misc
Corrective Action Required
08/07/2020
- Truss hangers per plans - garage - EC#2 per plans - dining room - UFER ground required
All Rough Inspection - Residential Failed 8/13/2020 8/13/2020 08/13/2020
Misc
Corrective Action Required
08/10/2020
- EC#2 per plans - dining room
Electrical Service Inspection Passed 8/13/2020 8/13/2020 08/13/2020
Misc
Resolved
08/13/2020
All Rough Inspection - Residential Passed 8/14/2020 8/14/2020 08/14/2020
Misc
Resolved
08/14/2020
Driveway Inspection Partial 8/28/2020 8/28/2020 08/28/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 8/28/2020 8/28/2020 08/28/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 9/3/2020 9/3/2020 09/04/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 9/3/2020 9/3/2020 09/04/2020
Misc
Informational
08/28/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sewer Service Inspection - R Passed 10/5/2020 (1:30) 10/5/2020 10/05/2020
Water Service Inspection - R Passed 10/8/2020 (11:30) 10/8/2020 10/08/2020
Occupancy Inspection - Codes Residential Failed 10/20/2020 10/20/2020 10/20/2020
Misc
Corrective Action Required
10/20/2020
-Complete final grade and sod -Seal around all exterior light fixtures -Seal all penetrations in siding, seal along top of meter can and AC disconnect -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Guardrail required at front porch, more than 30” from grade -exterior light fixtures less than 8’ from walking surface must be tamper resistant sealed type fixtures -Security screws at back door -Complete hood exhaust in kitchen -Adjust attic access door lids in garage to fit and seal properly -Complete ceiling light fixture install above front entry -Resolve outstanding inspection fee(s)
Occupancy Inspection - Codes Residential Temporary C of O 10/22/2020 10/22/2020 10/22/2020
Misc
Corrective Action Required
10/20/2020
**TCO ISSUED UNTIL 11-20-2020** -Complete final grade and sod -Seal around all exterior light fixtures -Seal all penetrations in siding, seal along top of meter can and AC disconnect -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Guardrail required at front porch, more than 30” from grade -exterior light fixtures less than 8’ from walking surface must be tamper resistant sealed type fixtures -Complete ceiling light fixture install above front entry -Resolve outstanding inspection fee(s)
Plot Plan Inspection Passed 12/09/2020
Occupancy Inspection - Codes Residential Full C of O 12/9/2020 12/9/2020 12/09/2020
Misc
Resolved
12/09/2020
Documents & Images
Date Uploaded File Type Document Name
04/21/2020 Application Form APP/LT FORM
04/21/2020 85 Reserve at Stoney Creek 1st Floor Layout- signed
04/21/2020 85 Reserve at Stoney Creek 2nd Floor Layout- signed
04/21/2020 LOT 85 FINAL
04/21/2020 RR #85 - Prescott - Mediterranean - Sheets- signed
04/21/2020 400223
04/23/2020 Plans APPROVED HOUSE PLANS
04/23/2020 Drawing APPROVED 1ST FLOOR LAYOUT
04/23/2020 Drawing APPROVED 2ND FLOOR LAYOUT
04/23/2020 Specifications APPROVED TRUSS PACKAGE
04/23/2020 Letter Codes Residential Plan Review
04/28/2020 Plans Approved Plot Plan
04/28/2020 Receipt Receipt for transaction:2020-001760
04/28/2020 Letter DS Building Permit
05/11/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/02/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter INSPECTION SUMMARY
06/05/2020 Letter INSPECTION SUMMARY
06/08/2020 Letter INSPECTION SUMMARY
07/27/2020 Letter INSPECTION SUMMARY
07/29/2020 Letter INSPECTION SUMMARY
07/29/2020 Letter INSPECTION SUMMARY
07/29/2020 Letter INSPECTION SUMMARY
07/29/2020 Letter INSPECTION SUMMARY
07/31/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/07/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/13/2020 Letter INSPECTION SUMMARY
08/13/2020 Letter INSPECTION SUMMARY
08/14/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
08/28/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter Codes Temporary Certificate of Occupancy
10/22/2020 Receipt Receipt for transaction: 2020-007098
12/09/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter Field Certificate of Occupancy
12/09/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home