Permit Application Status

PRRES20200989


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200989
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - PARTIAL FINISHED BASEMENT
04/17/2020
04/23/2020
10/23/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/22/2020 04/23/2020
Dylan Eppert
Basement opening elevations
Corrective Action Required
04/22/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan. missing front and rear MBOE
Planning Review (RES) Approved 04/24/2020 04/22/2020
Dylan Eppert
Residential Plan Review Approved 04/22/2020 04/22/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $994.32 $994.32 Paid 04/23/2020
8331507-Sewer Connection Fee $330.00 $330.00 Paid 04/23/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 04/23/2020
Water Meter Fee $425.02 $425.02 Paid 04/23/2020
Right of Way Permit Fee $80.00 $80.00 Paid 04/23/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/23/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 09/16/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Not Ready 5/8/2020 5/8/2020 05/08/2020
Misc
Corrective Action Required
05/08/2020
INSPECTION NOT READY, NOT PERFORMED - POST ADDRESS - - BACKFILL AROUND FOUNDATION FOR ACCESS - - PLUMBING NOT COMPLETE, STILL BEING INSTALLED AT TIME OF INSPECTION, HAVE INSPECTION READY BY 7 AM DAY SCHEDULED- - RE ESTABLISH EROSION CONTROL AT LOT PRIOR TO INSPECTION - NOT READY FEE
Erosion Control Inspection Residential Failed 5/8/2020 05/08/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/08/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 5/12/2020 5/12/2020 05/12/2020
Misc
Corrective Action Required
05/08/2020
- INSPECTION NOT PERFORMED, NO ACCESS - - BACKFILL AROUND FOUNDATION FOR ACCESS -
Underslab Plumbing Inspection - Residential Passed 5/14/2020 5/14/2020 05/14/2020
Misc
Resolved
05/14/2020
Electrical Service Inspection Passed 7/8/2020 7/8/2020 07/08/2020
Gas Piping Inspection - Residential Passed 7/8/2020 7/8/2020 07/08/2020
Gas Service Inspection - Residential Passed 7/8/2020 7/8/2020 07/08/2020
All Rough Inspection - Residential Failed 7/8/2020 7/8/2020 07/08/2020
Misc
Corrective Action Required
07/08/2020
- Seal all top plate penetrations - garage, basement - H2.5 strap missing master closet - Secure and protect pex at showers per manufacturer listing - Support DWV every 48” o.c. - Truss hangers per plan - Nail dbl/triple truss per plans - Remove back porch lid so that both truss hangers can be inspected - Install missing window in kitchen - EC#2 Hold down per plans - Fireblock all traps and tubs, no light through - Anchor all columns in basement - Fireblock every 10’ vertical between framing and foundation wall in basement
All Rough Inspection - Residential Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/10/2020
- Secure and protect pex at showers per manufacturer listing - secure pex to support in bath #2 - Nail dbl truss per plans- above master bed/bath/closet - Install missing window in kitchen - Per contractor currently on backorder with manufacturer
All Rough Inspection - Residential Failed 7/13/2020 7/13/2020 07/13/2020
Misc
Corrective Action Required
07/10/2020
- Install missing window in kitchen - Per contractor currently on backorder with manufacturer OK to Insulate
Sewer Service Inspection - R Passed 8/17/2020 (10:15) 8/17/2020 08/17/2020
Water Service Inspection - R Passed 8/18/2020 (1:00) 8/18/2020 08/18/2020
All Rough Inspection - Residential Passed 08/18/2020
Misc
Resolved
08/18/2020
Driveway Inspection Passed 8/20/2020 (Ready Now) 8/20/2020 08/20/2020
Misc
Informational
08/20/2020
On Thursday, 8-20-2020. I conducted a field inspection for the drive approach and found sub-grade and forming meets standards and passes inspection.
Footing Inspection - Residential Passed 9/15/2020 9/15/2020 09/15/2020
Occupancy Inspection - Codes Residential Failed 9/15/2020 9/15/2020 09/15/2020
Misc
Corrective Action Required
09/15/2020
-All outstanding fees to be paid in full -Final grade per approved Plot plan and sod -complete downspout installation -minimum 36” splash blocks at downspouts -Sump to discharge minimum 36” from foundation -Seal unused hole in electric meter can -Complete conductor termination at condensing unit, NM Conductor not allowed in exterior raceway -Remove trash and construction debris -Identified dedicated circuits as non-GFCI protected in garage and unfinished basement -Replace damaged attic access hatch -Provide provision to drain water distribution system at main shut off valve -Open outlet box at fireplace -Repair cut out sheet rock at fireplace, Accessible conductors
Piers/Caissons Inspection - Residential Passed 09/22/2020
Occupancy Inspection - Codes Residential Failed 9/22/2020 9/22/2020 09/22/2020
Misc
Corrective Action Required
09/15/2020
-Final grade and sod -Obtain lawn irrigation system permit -minimum 36” splash blocks at downspouts -Sump to discharge minimum 36” from foundation -Handrail required at garage steps, 4 rises -Open outlet and switch box(s) at fireplace -Final driveway inspection
Occupancy Inspection - Codes Residential Temporary C of O 9/23/2020 9/23/2020 09/23/2020
Misc
Corrective Action Required
09/22/2020
-Final grade and sod OK for TCO
Erosion Control Inspection Residential Passed 10/23/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/08/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 10/23/2020
Occupancy Inspection - Codes Residential Full C of O 10/23/2020 10/23/2020 10/23/2020
Misc
Resolved
10/23/2020
-Final grade and sod OK for TCO
Documents & Images
Date Uploaded File Type Document Name
04/17/2020 Application Form H4 #53 - PERMIT APP
04/19/2020 LOT 53 FINAL
04/19/2020 53 Hawthorne Ridge Roof Layout- signed
04/19/2020 H4 #53 - Carbondale - Old World - Sheets- signed
04/19/2020 400213
04/22/2020 Plans Approved House Plans
04/22/2020 Plans Approved Roof Truss Layout
04/22/2020 Specifications Approved Roof Truss Package
04/22/2020 Letter Codes Residential Plan Review
04/22/2020 Approved Planning Elevations
04/23/2020 Plot Plan APPROVED PLOT PLAN
04/23/2020 Receipt Receipt for transaction:2020-001699
04/23/2020 Letter DS Building Permit
05/01/2020 Letter Foundation inspection report
05/01/2020 Letter Footing inspection report
05/08/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Engineer Report/Study 68 Hawthorne Ridge Framing Letter
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
08/17/2020 Letter INSPECTION SUMMARY
08/18/2020 Letter INSPECTION SUMMARY
08/18/2020 Letter INSPECTION SUMMARY
09/15/2020 Letter INSPECTION SUMMARY
09/15/2020 Letter INSPECTION SUMMARY
09/16/2020 Receipt Receipt for transaction: 2020-006267
09/22/2020 Letter INSPECTION SUMMARY
09/22/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter Codes Temporary Certificate of Occupancy
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter Codes 10 Day Letter (Verify Submittal (RES))
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter Codes Final Certificate of Occupancy
10/23/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home