Summary
PRRES20200522
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED PATIO
02/27/2020
03/30/2020
09/22/2020
05/17/2021
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
TROY@BELLAHHOMES.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 03/26/2020 03/30/2020
Steve Conrick
Plot Plan Review Approved 03/27/2020 03/27/2020
Steve Conrick
Basement egress
Corrective Action Required
03/26/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. Missing egress shown on elevations. make sure LAGs meet MBOEs
Residential Plan Review Approved 03/13/2020 03/16/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,350.27 $1,350.27 Paid 03/30/2020
Right of Way Permit Fee $80.00 $80.00 Paid 03/30/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/30/2020
8331507-Sewer Connection Fee $510.00 $510.00 Paid 03/30/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 03/30/2020
Water Meter Fee $425.02 $425.02 Paid 03/30/2020
Additional Permit Fee $30.00 $30.00 Paid 03/30/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/7/2020 04/16/2020
Informational
04/16/2020
-3rd party by signed & stamped by David Ainsworth - notes : ufer ground East foundation wall 5' north of garage wall
Underslab Plumbing Inspection - Residential Passed 5/6/2020 5/6/2020 at 7:22 AM 05/06/2020
Sewer Service Inspection - R Passed 5/12/2020 (10:15) 5/12/2020 05/12/2020
Water Service Inspection - R Passed 5/13/2020 at 11:05 AM 05/13/2020
All Rough Inspection - Residential Partial 8/7/2020 8/7/2020 08/07/2020
Misc
Informational
08/07/2020
- PORTAL FRAMING ONLY - - STHD14 NAILED OFF, NAILING PATTERN HEADER APPROVED -
All Rough Inspection - Residential Failed 9/14/2020 9/14/2020 09/14/2020
Misc
Corrective Action Required
09/14/2020
-Erosion control requires continuous maintenance -Gas vent clearance at roof penetration not compliant with figure G2427.6.4 2018 IRC -Provide soffit vents -Fire block concealed space in master bath -Fire block vertical to horizontal in shower space at steel column and provide structural straps -Ensure all top and bottom plate penetrations are fire blocked -Complete plumbing installation for tub in master bath -Complete and repair bath exhaust duct installation and terminations per code -Nail plate protection water distribution piping in pantry -Door jambs shall be installed with solid backing in a manner so no void exists between the strike side of the jamb and the frame opening for a vertical distance of twelve (12) inches each side of the strike. Filler material shall consist of a solid wood block. -At least two (2) wood screws, three (3) inches in length, penetrating at least one inch into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. -electrical bond connection shall be made downstream of the individual gas meter and upstream of any CSST connection per manufacturers installation instructions -Identify white service entrance conductor as ungrounded conductor At both ends -NM cables shall be run either through bored holes in joists or on running boards in unfinished basement -Provide joist hangers at headered floor joist, basement -Complete HVAC line set -Provide hardwired interconnected smoke alarm in basement area -Plan requires 2 x 12 ridge over bedroom two and bedroom four -Fire block concealed space bedroom three shower area -Provide attic access -Provide joist hangers in garage from steel beam to header at stairs DO NOT INSULATE OR ROCK RE-INSPECTION REQUIRED
Electrical Service Inspection Failed 9/14/2020 9/14/2020 09/14/2020
Misc
Corrective Action Required
09/14/2020
Identify white service Entrance conductor as ungrounded conductor
Gas Piping Inspection - Residential Passed 9/14/2020 9/14/2020 09/14/2020
Gas Service Inspection - Residential Failed 9/14/2020 9/14/2020 09/14/2020
Misc
Corrective Action Required
09/14/2020
-improper gas vent clearance at roof penetration -Improper electrical bonding of gas piping See all rough inspection report for detailed description
All Rough Inspection - Residential Failed 9/17/2020 9/17/2020 09/17/2020
Misc
Corrective Action Required
09/14/2020
-Erosion control requires continuous maintenance -Complete plumbing installation for tub in master bath -Door jambs shall be installed with solid backing in a manner so no void exists between the strike side of the jamb and the frame opening for a vertical distance of twelve (12) inches each side of the strike. Filler material shall consist of a solid wood block. ( UPPER DECK DOORS) -At least two (2) wood screws, three (3) inches in length, penetrating at least one inch into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. COF OK TO INSULATE RE-INSPECTION REQUIRED
Gas Service Inspection - Residential Passed 9/17/2020 9/17/2020 09/17/2020
Misc
Resolved
09/17/2020
Electrical Service Inspection Passed 9/17/2020 9/17/2020 09/17/2020
Misc
Resolved
09/17/2020
Sidewalk Inspection Partial 10/23/2020 (A.M.) 10/23/2020 10/23/2020
Misc
Corrective Action Required
10/23/2020
Forms were placed and aggregate was present and compacted, but under water. Need to wait for it to dry out. RP 10-23-20
Sidewalk Inspection Partial 10/28/2020 10/28/2020 10/28/2020
Misc
Corrective Action Required
10/23/2020
Forms were placed and aggregate was present and compacted, but under water. Need to wait for it to dry out. RP 10-23-20
Misc
Informational
10/28/2020
Terry’s crew pumped out excess water. RP 10-28-20
Erosion Control Inspection Residential Failed 11/06/2020
Misc
Corrective Action Required
11/06/2020
-Deficient erosion control, methods require continuous maintenance. Reestablish erosion control at front and rear property lines within two days. -Immediate Street clean up required, front and rear -Post building address -No further inspections until issues are resolved
Sidewalk Inspection Passed 11/6/2020 11/6/2020 11/09/2020
Misc
Corrective Action Required
10/28/2020
Forms were placed and aggregate was present and compacted, but under water. Need to wait for it to dry out. RP 10-23-20
Misc
Informational
10/28/2020
Terry’s crew pumped out excess water. RP 10-28-20
Misc
Informational
11/09/2020
Finished sidewalk meets LS and ADA specs. RP 11-9-20
All Rough Inspection - Residential Passed 01/19/2021
Misc
Resolved
01/19/2021
-Erosion control requires continuous maintenance -Ensure all top and bottom plate penetrations are fire blocked ( low volt at SCH 40 column, upper deck room, 2nd floor bed near closet)) -Complete plumbing installation for tub in master bath -Complete and repair bath exhaust duct installation and terminations per code ( 1/2 bath near garage metallic tape) -Door jambs shall be installed with solid backing in a manner so no void exists between the strike side of the jamb and the frame opening for a vertical distance of twelve (12) inches each side of the strike. Filler material shall consist of a solid wood block. -At least two (2) wood screws, three (3) inches in length, penetrating at least one inch into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. DO NOT INSULATE OR ROCK RE-INSPECTION REQUIRED
Occupancy Inspection - Codes Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/19/2021
-Final grade and sod per approved plot -Remove excavation spoils from site -remove debris from street & sidewalk -Provide tamper resistant schrader valve caps at exterior HVAC equipment -Identify white insulated conductor to be used as current carrying conductor at both points of termination, condensing unit circuit -Seal top and sides of exterior lighting exposed to the elements -Secure grounding electrode conductor conduit to structure at electric meter enclosure -remove all paint covers from smoke/carbon monoxide alarms -return handrails, garage -complete range installation -install smoke alarm in basement
Occupancy Inspection - Codes Residential Temporary C of O 1/21/2021 1/21/2021 01/21/2021
Misc
Corrective Action Required
01/19/2021
-Final grade and sod per approved plot -Remove excavation spoils from site -remove debris from street & sidewalk -Seal top and sides of exterior lighting exposed to the elements TCO VALID THROUGH 02/21/2021
Occupancy Inspection - Codes Residential Temporary C of O 02/22/2021
Misc
Corrective Action Required
01/21/2021
-Final grade and sod per approved plot -Remove excavation spoils from site -remove debris from street & sidewalk -Seal top and sides of exterior lighting exposed to the elements TCO EXTENSION VALID THROUGH 03/21/2021 DUE TO WEATHER CONDITIONS
Erosion Control Inspection Residential Passed 05/17/2021
Misc
Resolved
05/17/2021
-Deficient erosion control, methods require continuous maintenance. Reestablish erosion control at front and rear property lines within two days. -Immediate Street clean up required, front and rear -Post building address -No further inspections until issues are resolved
Plot Plan Inspection Passed 05/17/2021
Occupancy Inspection - Codes Residential Full C of O 5/17/2021 5/17/2021 05/17/2021
Misc
Resolved
05/17/2021
-Final grade and sod per approved plot -Remove excavation spoils from site -remove debris from street & sidewalk -Seal top and sides of exterior lighting exposed to the elements TCO EXTENSION VALID THROUGH 03/21/2021 DUE TO WEATHER CONDITIONS
Documents & Images
Date Uploaded File Type Document Name
03/25/2020 BHPPergolaOxford4Lot101Sealed
03/25/2020 Lot101PlotPlan
03/26/2020 Application and Irrigation Permit
03/26/2020 Letter Codes Residential Plan Review
03/27/2020 Plot Plan PP 101 FINAL REV 1
03/27/2020 Letter Codes Residential Plan Review
03/27/2020 Plot Plan PP 101 FINAL REV 2
03/27/2020 Plot Plan Lot 101 PP - CITY STAMPED
03/30/2020 Plans CSM PergolaOxford4Lot101Sealed CITY STAMPED
03/30/2020 Receipt Receipt for transaction:2020-001312
03/30/2020 Letter DS Building Permit
04/08/2020 Engineer Report/Study 3229 SW Mary St LSMO Pergola Park Lot 101 Bella Permit 2020-0522 3rd Party Footing Inspection Sealed 4-7-20
04/16/2020 Letter INSPECTION SUMMARY
05/06/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
08/07/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/17/2020 Bellah Homes 3229 SW Mary St LSMO Roof Framing Issues R Submittal 9-14-20
09/17/2020 Bellah Homes 3229 SW Mary St LSMO Roof Framing Issues R Submittal 9-14-20[12222]
09/17/2020 Letter INSPECTION SUMMARY
09/17/2020 Letter INSPECTION SUMMARY
09/17/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/28/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/09/2020 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter Codes Temporary Certificate of Occupancy
01/21/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter Codes Temporary Certificate of Occupancy
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter Codes Final Certificate of Occupancy
05/17/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home