Permit Application Status

PRRES20200452


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200452
Building Permit - Residential
Certificate of Occupancy
BRIAN CHANEY CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
02/24/2020
03/11/2020
10/22/2020
Locations
Contacts
BRIAN CHANEY CONSTRUCTION LLC, Address:2254 MILAM RD  
NICK ZVACEK CONSTRUCTION LLC, Address:1009 INDUSTRIAL DR, Phone:(816) 213-7204  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JEFF.BOEHM@ZVACEKCONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 02/26/2020 03/11/2020
Development Center
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
02/24/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provide square footage for covered deck
Plot Plan Review Approved 02/26/2020 03/03/2020
Kim Brennan
Deck location
Corrective Action Required
02/24/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show that this is a covered deck
Right-of-way
Corrective Action Required
02/24/2020

The right-of-way with dimensions must be provided on the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,082.00 $1,082.00 Paid 03/11/2020
Right of Way Permit Fee $80.00 $80.00 Paid 03/11/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/11/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 03/11/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 03/11/2020
Water Meter Fee $425.02 $425.02 Paid 03/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/11/2020 (1:30) 3/11/2020 at 1:40 PM 03/11/2020
Underslab Plumbing Inspection - Residential Passed 3/30/2020 3/30/2020 at 8:40 AM 03/30/2020
Suspended Slab Inspection Passed 04/20/2020
Informational
04/20/2020
Garage structural slab reinforced with #4 rebar at 12" oc EW-ok
Sewer Service Inspection - R Passed 6/26/2020 (11:30) 6/26/2020 at 1:15 PM 06/26/2020
Water Service Inspection - R Partial 6/26/2020 (11:15) 6/26/2020 06/26/2020
Water Service Inspection - R Passed 6/29/2020 (10:00) 6/29/2020 at 10:20 AM 06/29/2020
Electrical Service Inspection Passed 7/1/2020 7/1/2020 07/01/2020
Gas Service Inspection - Residential Failed 7/1/2020 7/1/2020 07/01/2020
Misc
Corrective Action Required
07/01/2020
-Provide min ten psi test pressure
All Rough Inspection - Residential Failed 7/1/2020 7/1/2020 at 9:20 AM 07/01/2020
Misc
Corrective Action Required
07/01/2020
**PROVIDE PLANS ON SITE FRAMING: -Provide min 2 anchors for each short sill plate in garage -Strap inner sides of the garage portal brace walls; add more nailing of h frames into stud per garage design document -Support valley and hip rafters above garage -Support roof beam above hallway/half bathroom to bearing wall -Install hangers for ceiling beam connections above foyer -Provide full bearing support for roof beam at front bedroom -Install exterior door frames per security code -Complete framing at deck door -Fb fireplace space from roof. Use 3/4” sheathing or other approved materials. Must make sure to have minimum 1” clearance from the fireplace vent -Lag deck ledger board every 16” -Nail master bedroom ceiling beam hangers -Move roof support struts above laundry/master bathroom wall to bearing point above I beam below -Install hangers for joists at basement stair wall; nail hanger at double joist connection -Fb basement wall space vertically every ten ft or less; Fb wall from ceiling fur down space -Toe nail basement joists to top plates with 4-8d or 3-10d box nails -Provide min 2 anchors for each short sill plate in basement; anchor within 12” of door -Tempered glass window required within 2 ft of basement exterior door PLUMBING: -Strap top plates at master bathroom exterior wall ELECTRICAL: -Make sure to provide proper clearance from basement bedroom closet storage space **OK TO INSULATE
Driveway Inspection Partial 7/7/2020 (A.M.) 7/7/2020 07/07/2020
Misc
Informational
07/07/2020
Driveway - forms and materials passed pre-inspection.
Electrical Service Inspection Passed 7/8/2020 07/08/2020
Gas Service Inspection - Residential Passed 7/8/2020 07/08/2020
Misc
Resolved
07/08/2020
-Provide min ten psi test pressure
All Rough Inspection - Residential Failed 7/8/2020 at 8:15 AM 07/08/2020
Misc
Corrective Action Required
07/01/2020
FRAMING: -Provide min 2 anchors for each short sill plate in garage -Strap inner sides of the garage portal brace walls -Fb fireplace space from roof. Use 3/4” sheathing or other approved materials. Must make sure to have minimum 1” clearance from the fireplace vent -Nail hanger at double joist connection to triple joist (above stair wall in basement) -Fb basement wall space vertically every ten ft or less; Fb wall from ceiling fur down space **Not done. Cannot use 7/16" sheathing; must fb vertically every ten ft or less. Seal gap at top; fb bathroom wall from fur down space -Tempered glass window required within 2 ft of basement exterior door PLUMBING: -Strap top plate at master bathroom exterior wall bored more than 50% **OK TO INSULATE
All Rough Inspection - Residential Passed 7/13/2020 7/13/2020 at 8:00 AM 07/13/2020
Misc
Resolved
07/13/2020
FRAMING: -Provide min 2 anchors for each short sill plate in garage -Strap inner sides of the garage portal brace walls -Fb fireplace space from roof. Use 3/4” sheathing or other approved materials. Must make sure to have minimum 1” clearance from the fireplace vent -Nail hanger at double joist connection to triple joist (above stair wall in basement) -Fb basement wall space vertically every ten ft or less; Fb wall from ceiling fur down space **Not done. Cannot use 7/16" sheathing; must fb vertically every ten ft or less. Seal gap at top; fb bathroom wall from fur down space -Tempered glass window required within 2 ft of basement exterior door PLUMBING: -Strap top plate at master bathroom exterior wall bored more than 50% **OK TO INSULATE
Driveway Inspection Passed 7/15/2020 7/15/2020 08/07/2020
Misc
Informational
07/07/2020
Driveway - forms and materials passed pre-inspection.
Misc
Informational
08/07/2020
Driveway - passed final inspection.
Occupancy Inspection - Codes Residential Failed 10/15/2020 10/15/2020 10/15/2020
Misc
Corrective Action Required
10/15/2020
-Piers inspection not approved on record -Obtain lawn irrigation permit -Install address -Install gutters, downspout and sump pump extension -Provide min 6” clearance from grade to bottom of siding -Shim gap between deck beam and posts -Exterior receptacles are currently covered for painting and not tested at this time -City amendment of the NEC requires all dedicated non-gfci receptacles in garage and unfinished basement to be identified (label, marking, etc) -Pendant light not allowed within master bathroom in zone -Provide a wall receptacle at kitchen countertop wider than 12” on right side of refrigerator -Lower the master bathtub trap down so that the trap weir is not above the vent connection -Fb floor penetration by trap -Install a backflow preventer at basement hose bibb -Mislabeled oven breaker
Piers/Caissons Inspection - Residential Passed 4/20/2020 (1:00) 10/15/2020 10/15/2020
Occupancy Inspection - Codes Residential Temporary C of O 10/20/2020 10/20/2020 10/20/2020
Misc
Corrective Action Required
10/15/2020
-Provide min 6” clearance from grade to bottom of siding -Shim gap between deck beam and posts -Sump pump extension
Occupancy Inspection - Codes Residential Full C of O 10/22/2020 10/22/2020 10/22/2020
Misc
Resolved
10/22/2020
-Provide min 6” clearance from grade to bottom of siding -Shim gap between deck beam and posts -Sump pump extension
Documents & Images
Date Uploaded File Type Document Name
02/24/2020 Letter Codes Residential Plan Review
03/11/2020 Receipt Receipt for transaction: 2020-001089
03/11/2020 Letter DS Building Permit
03/11/2020 Letter INSPECTION SUMMARY
03/12/2020 Plans DOC031220-030
03/30/2020 Letter INSPECTION SUMMARY
04/20/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/01/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
08/07/2020 Letter INSPECTION SUMMARY
10/15/2020 Letter INSPECTION SUMMARY
10/15/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter Codes Temporary Certificate of Occupancy
10/22/2020 Letter Codes Final Certificate of Occupancy
10/22/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home