Permit Application Status

PRRES20200384


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200384
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
02/18/2020
02/26/2020
10/22/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 02/20/2020 02/25/2020
Kim Brennan
City infrustructure
Corrective Action Required
02/18/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Please show manhole located on the front northeast side of the lot.
Basement elevation
Corrective Action Required
02/18/2020

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) MDP shows a daylight basement and not a walk-out.
Planning Review (RES) Approved 02/20/2020 02/18/2020
Kim Brennan
Residential Plan Review Approved 02/20/2020 02/18/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,281.74 $1,281.74 Paid 02/26/2020
Right of Way Permit Fee $80.00 $80.00 Paid 02/26/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/26/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 02/26/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 02/26/2020
Water Meter Fee $425.02 $425.02 Paid 02/26/2020
Not Ready Inspection Fee $50.00 $50.00 Paid 10/19/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/20/2020 (2:00) 3/20/2020 03/20/2020
Underslab Plumbing Inspection - Residential Passed 4/16/2020 4/16/2020 04/16/2020
Erosion Control Inspection Residential Failed 5/11/2020 05/11/2020
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/11/2020
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Piers/Caissons Inspection - Residential Failed 5/11/2020 (11:00) 5/11/2020 05/11/2020
Misc
Corrective Action Required
05/11/2020
- PUMP WATER OUT OF DECK PIERS -
Piers/Caissons Inspection - Residential Not Ready 5/12/2020 5/12/2020 05/12/2020
Misc
Corrective Action Required
05/11/2020
- PUMP WATER OUT OF DECK PIERS -
Misc
Corrective Action Required
05/12/2020
- DECK PIERS FULL OF WATER -
Erosion Control Inspection Residential Failed 5/12/2020 05/12/2020
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/11/2020
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/12/2020
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Piers/Caissons Inspection - Residential Passed 5/15/2020 (11:30) 5/15/2020 05/15/2020
Misc
Resolved
05/15/2020
(1) 24 X 36 (1) 30 X 36
Misc
Resolved
05/15/2020
All Rough Inspection - Residential Failed 6/10/2020 6/10/2020 06/10/2020
Misc
Corrective Action Required
06/10/2020
- Garage PFH per plans - Truss H2.5 missing- garage, dining room, front entry - Fireblock deadspace arch columns in dining room - Secure and protect PEX at showers - DWV boca protection plates bedroom #2 closet, PEX at laundry - Security blocking at backdoor to deck - Seal around Fireblock gaps at deadspace by kitchen entrance from hall - Seal gaps at Fireblock edges at fireplace - Secure Ward flex gas line at deck fireplace - Remove cover at deck fireplace to allow for inspection of Fireblock - Missing truss hanger per plan master bedroom - Support DWV every 48” oc - Complete DWV master bath - Seal gaps at Fireblock between top plate and foundation basement - Seal gaps at vertical Fireblock at studs basement
Electrical Service Inspection Passed 6/10/2020 6/10/2020 06/10/2020
Gas Piping Inspection - Residential Failed 6/10/2020 6/10/2020 06/10/2020
Misc
Corrective Action Required
06/10/2020
- Secure Ward flex gas line at deck fireplace
Gas Service Inspection - Residential Failed 06/10/2020
Misc
Corrective Action Required
06/10/2020
- Secure Ward flex gas line at deck fireplace
All Rough Inspection - Residential Failed 6/12/2020 6/12/2020 06/12/2020
Misc
Corrective Action Required
06/10/2020
- Truss H2.5 missing-dining room - Seal around Fireblock gaps at deadspace by kitchen entrance from hall - Seal gaps at Fireblock edges at fireplace - Seal romex penetration through Fireblock in deck fireplace - Missing truss hanger per plan master bedroom
Gas Piping Inspection - Residential Passed 6/12/2020 6/12/2020 06/12/2020
Misc
Resolved
06/12/2020
Gas Service Inspection - Residential Passed 6/12/2020 6/12/2020 06/12/2020
Misc
Resolved
06/12/2020
All Rough Inspection - Residential Failed 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/12/2020
- Seal romex penetration through Fireblock in deck fireplace
Sewer Service Inspection - R Passed 6/15/2020 (1:00) 6/15/2020 06/15/2020
All Rough Inspection - Residential Passed 6/16/2020 6/16/2020 06/16/2020
Misc
Resolved
06/16/2020
Water Service Inspection - R Passed 6/25/2020 (11:30) 6/25/2020 06/25/2020
Occupancy Inspection - Codes Residential Failed 8/10/2020 8/10/2020 08/10/2020
Misc
Corrective Action Required
08/10/2020
- Post permanent address - Submit as graded plot plan for review - Complete final grade and sod - Obtain lawn irrigation system permit - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Guardrail required at front porch, more than 30” from grade - Final driveway/sidewalk inspection required - Locking devices required at front door, back door, basement door, garage door - Smoke detector required inside front bedroom - Smoke / CO detector required outside of front bedroom within vicinity per code - Front bedroom window, tempered glass required where glazing is within 24” of either side of the plane of the door in a closed position - Security screws, provide (2) 3” screws each exterior hinge and strike plate at back door, basement door - Garage door should be self closing - Remove paint covers from all smokes - GFCI protection required at laundry receptacle - Spindles at interior stairs - Handrail at interior stairs - Remove flue vent for water heater at furnace - GFCI protection at water heater receptacle in basement - GFCI protection at basement bath receptacle by toilet
Driveway Inspection Passed 7/1/2020 (Ready Now) 7/1/2020 08/13/2020
Misc
Informational
08/13/2020
I conducted a visual inspection of the driveway and find the driveway acceptable to pass for inspection
Plot Plan Inspection Passed 8/26/2020 08/26/2020
Occupancy Inspection - Codes Residential Temporary C of O 8/26/2020 8/26/2020 08/26/2020
Misc
Corrective Action Required
08/10/2020
- Front bedroom window, tempered glass required where glazing is within 24” of either side of the plane of the door in a closed position OK for TCO
Occupancy Inspection - Codes Residential Failed 10/15/2020 10/15/2020 10/15/2020
Misc
Corrective Action Required
08/26/2020
- RESOLVE OUTSTANDING INSPECTION FEE(S) BEFORE FINAL C OF O - FINAL DRIVEWAY INSPECTION
Sidewalk Inspection Passed 7/1/2020 (Ready Now) 7/1/2020 10/15/2020
Misc
Informational
10/15/2020
The sidewalk meet city specification and passes inspection
Occupancy Inspection - Codes Residential Full C of O 10/23/2020 10/23/2020 10/22/2020
Misc
Resolved
10/22/2020
Documents & Images
Date Uploaded File Type Document Name
02/19/2020 Letter Codes Residential Plan Review
02/26/2020 Receipt Receipt for transaction: 2020-000839
02/26/2020 Letter DS Building Permit
02/27/2020 Engineer Report/Study DOC022720-008
02/27/2020 Plot Plan DOC022720-009
03/20/2020 Letter INSPECTION SUMMARY
04/16/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/16/2020 Letter INSPECTION SUMMARY
06/25/2020 Letter INSPECTION SUMMARY
08/10/2020 Letter INSPECTION SUMMARY
08/25/2020 Plot Plan As Graded Plot Plan
08/26/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter Codes Temporary Certificate of Occupancy
10/15/2020 Letter INSPECTION SUMMARY
10/19/2020 Receipt Receipt for transaction: 2020-007016
10/22/2020 Letter Field Certificate of Occupancy
10/22/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home