Permit Application Status

PRRES20200368


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200368
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
02/14/2020
03/03/2020
08/22/2020
02/27/2024
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/05/2020 03/03/2020
Development Center
Legal description
Corrective Action Required
03/03/2020

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Wrong plat
Drainage swales
Corrective Action Required
03/03/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provided Show cross section elevations throughout the swale.
Spot elevations
Corrective Action Required
03/03/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. continue contours to property line
As-graded plot plan
Corrective Action Required
03/03/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/05/2020 03/03/2020
Development Center
Plot Plan Review Rejected 02/19/2020 02/24/2020
Steve Conrick
Legal description
Corrective Action Required
02/24/2020

The legal description, including plat or phase number and lot number, and street address must be provided on the plot plan. Wrong plat
Drainage swales
Corrective Action Required
02/24/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provided Show cross section elevations throughout the swale.
Spot elevations
Corrective Action Required
02/24/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. continue contours to property line
As-graded plot plan
Corrective Action Required
02/24/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 02/19/2020 02/24/2020
Steve Conrick
01 One (1) complete permit application
Corrective Action Required
02/24/2020

One (1) complete permit application Lucas Electric does not have a business license
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,007.10 $1,007.10 Paid 03/03/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/03/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/03/2020
8331507-Sewer Connection Fee $420.00 $420.00 Paid 03/03/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 03/03/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 03/03/2020
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 03/03/2020
8331506-EFHB Maybrook, Full $596.54 $596.54 Paid 03/03/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/14/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 3/13/2020 (1:30) 3/13/2020 03/13/2020
Misc
Corrective Action Required
03/13/2020
Send engineers letter to office to attach to permit (3) #4 continuous upsize pads
Erosion Control Inspection Residential Failed 4/7/2020 04/07/2020
Misc
Corrective Action Required
04/07/2020
Your erosion control is in violation and needs to be taken care of and restored befor you can recieve more inspections.
Underslab Plumbing Inspection - Residential Failed 4/22/2020 4/22/2020 04/22/2020
Misc
Corrective Action Required
04/22/2020
- Post address -
Underslab Plumbing Inspection - Residential Passed 4/29/2020 4/29/2020 04/29/2020
Misc
Resolved
04/29/2020
Gas Service Inspection - Residential Failed 6/11/2020 6/11/2020 06/11/2020
Misc
Corrective Action Required
06/11/2020
- Bond gas line - - Secure ward flex at fireplace - - Secure ward flex vertical run at foundation by furnace
All Rough Inspection - Residential Not Ready 7/14/2020 7/14/2020 07/14/2020
Misc
Corrective Action Required
07/14/2020
NO INSPECTION PERFORMED - NO CITY APPROVED PLANS ON SITE
Gas Piping Inspection - Residential Passed 7/16/2020 7/16/2020 07/16/2020
Gas Service Inspection - Residential Passed 7/16/2020 7/16/2020 07/16/2020
Misc
Resolved
07/16/2020
Electrical Service Inspection Failed 7/16/2020 7/16/2020 07/16/2020
Misc
Corrective Action Required
07/16/2020
-COLOR CODE/LABEL GROUNDING ELECTRODE CONDUCTOR AT MAIN DISCONNECT PANEL -
All Rough Inspection - Residential Failed 7/16/2020 7/16/2020 07/16/2020
Misc
Corrective Action Required
07/14/2020
- Protection plate at DWV laundry - Secure NM and data cable at fireplace in front of flue vent - Terminate NM at ceiling in master bed - Seal all upward penetrations - garage - Support and protect pex at tubs/showers per manufacturer listed product - Garage PFH per plans - Nail all rafter to ceiling joist together at connection per nailing schedule - Support DWV ever 48” o.c., traps are not considered support - Fireblock vertical to horizontal at all fir downs in basement - Color code/label grounding electrode conductor at main disconnect panel
Electrical Service Inspection Passed 7/22/2020 7/22/2020 07/22/2020
Misc
Resolved
07/22/2020
All Rough Inspection - Residential Failed 7/22/2020 7/22/2020 07/22/2020
Misc
Corrective Action Required
07/16/2020
- Garage PFH per plans OK to Insulate
All Rough Inspection - Residential Passed 7/27/2020 7/27/2020 07/27/2020
Misc
Resolved
07/27/2020
Driveway Inspection Partial 8/4/2020 8/4/2020 08/04/2020
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 8/11/2020 8/11/2020 08/12/2020
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Erosion Control Inspection Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Resolved
09/08/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/08/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - RE ESTABLISH AND MAINTAIN SILT FENCE AT FRONT OF LOT - CLEAN MUD AND DEBRIS BUILDUP AT STORM SEWER INLET AT FRONT OF LOT - EROSION CONTROL REQUIRED AT BACK OF LOT
Sewer Service Inspection - R Passed 9/9/2020 (2:00) 9/9/2020 09/09/2020
Water Service Inspection - R Passed 9/11/2020 (11:15) 9/11/2020 09/11/2020
Piers/Caissons Inspection - Residential Passed 10/27/2020
Erosion Control Inspection Residential Failed 10/27/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/08/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - RE ESTABLISH AND MAINTAIN SILT FENCE AT FRONT OF LOT - CLEAN MUD AND DEBRIS BUILDUP AT STORM SEWER INLET AT FRONT OF LOT - EROSION CONTROL REQUIRED AT BACK OF LOT
Occupancy Inspection - Codes Residential Failed 10/27/2020 10/27/2020 10/27/2020
Misc
Corrective Action Required
10/27/2020
-Provide building address, minimum 4” height & 1/2” stroke, contrasting background and must also be placed in illuminated area -Submit as graded plot plan for approval -final grade per approved as graded plot and sod -Downspouts and sump piping to discharge minimum 36” from foundation -Provide joist hangers for rim joists and floor joists exceeding 4’ span -Attach ledgers to structure per code or fastener installation instructions -Complete guard rail at deck stairs per code -Complete deck stair landing -Seal all exterior penetrations -Provide ladder at basement egress window well or raise grade to less than 44” to top of well -complete kitchen sink plumbing -Provide attic access lid -Repair holes in garage sheet rock -plug gas outlet in laundry room -rock bottom of stairs to basement or make area inaccessible -GEC connection to concrete encased electrode required to remain accessible -Label dedicated circuits at receptacle as non-GFCI protected in unfinished basement -Provide AFCI protection of entry circuit -remove trash and construction debris from interior and exterior -four 3” wood screws at exterior door strike -Provide letter from EOR regarding footing inspection -DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - RE ESTABLISH AND MAINTAIN SILT FENCE AT FRONT OF LOT - CLEAN MUD AND DEBRIS BUILDUP AT STORM SEWER INLET AT FRONT OF LOT - RE ESTABLISH EROSION CONTROL AT BACK OF LOT
Footing Inspection - Residential Passed 10/29/2020
Misc
Resolved
10/29/2020
Occupancy Inspection - Codes Residential Temporary C of O 10/29/2020 10/29/2020 10/29/2020
Misc
Corrective Action Required
10/27/2020
-Submit as graded plot plan for approval -final grade per approved as graded plot and sod -Downspouts and sump piping to discharge minimum 36” from foundation OK FOR TCO - EXPIRES 11/12/20
Plot Plan Inspection Passed 12/9/2020 12/09/2020
Deck Final Inspection - Residential Failed 12/9/2020 12/9/2020 12/09/2020
Misc
Corrective Action Required
12/09/2020
-JOIST HANGERS MISSING NAILS -4’ SPHERE SHALL NOT PASS THROUGH RAILING -POST TO BEAM CONNECTION PER CODE
Documents & Images
Date Uploaded File Type Document Name
02/24/2020 Letter Codes Residential Plan Review
03/03/2020 Receipt Receipt for transaction: 2020-000943
03/03/2020 Letter DS Building Permit
03/13/2020 Letter INSPECTION SUMMARY
04/07/2020 Letter DE-Daily Inspection Summary
04/22/2020 Letter INSPECTION SUMMARY
04/29/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/30/2020 Engineer Report/Study Final_06.16.2020_DPier_LSMO_Concrete Design
06/30/2020 Engineer Report/Study Final_2020.06.17_DPier_LSMO_Concrete Design
07/14/2020 Letter INSPECTION SUMMARY
07/14/2020 Receipt Receipt for transaction:2020-004458
07/16/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/27/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/09/2020 Letter INSPECTION SUMMARY
09/11/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
10/27/2020 1614 SW BLACKSTONE PL SOIL
10/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter Codes Temporary Certificate of Occupancy
12/03/2020 Plot Plan APPROVED PLOT PLAN
12/09/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home