Permit Application Status

PRRES20200309


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200309
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
02/11/2020
02/18/2020
10/08/2020
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
PERMITTING@JFECONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 02/13/2020 02/18/2020
Jennifer Thompson
07 Identify emergency escape openings from bedrooms
Corrective Action Required
02/11/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Please identify that the label "h" in bedrooms 3 and 4 are to be egress windows.
30 Identify type of protection used in unfinished areas under
Corrective Action Required
02/11/2020

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
31 Identify type of joist package or floor truss package (if used)
Corrective Action Required
02/11/2020

Identify type of joist package or floor truss package (if used) complete with layouts, fastening details, blocking and bracing requirements and minimum sheathing. These drawing must be stamped by a licensed professional.
Plot Plan Review Approved 02/13/2020 02/18/2020
Jennifer Thompson
Basement egress
Corrective Action Required
02/11/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. Please show this information for the egress window in the rear of the basement
Drainage swales
Corrective Action Required
02/11/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable).
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,439.74 $1,439.74 Paid 02/18/2020
Right of Way Permit Fee $80.00 $80.00 Paid 02/18/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/18/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/18/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 02/18/2020
Water Meter Fee $425.02 $425.02 Paid 02/18/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/2/2020 3/2/2020 03/02/2020
Underslab Plumbing Inspection - Residential Passed 3/26/2020 3/26/2020 03/26/2020
All Rough Inspection - Residential Partial 4/13/2020 4/13/2020 04/13/2020
Misc
Informational
04/13/2020
- GARAGE PORTAL FRAME HOLDDOWNS NAILED OFF, NAILING PATTERN, HEADER TO KING STUD STRAPS, 5/8 ANCHOR BOLTS & DOUBLE BOTTOM PLATE, OK TO COVER
Water Service Inspection - R Passed 5/13/2020 at 1:50 PM 05/13/2020
Sewer Service Inspection - R Passed 5/14/2020 (11:30) 5/14/2020 05/14/2020
Gas Piping Inspection - Residential Passed 6/10/2020 06/10/2020
Gas Service Inspection - Residential Passed 6/10/2020 6/10/2020 06/10/2020
Electrical Service Inspection Passed 6/10/2020 6/10/2020 06/10/2020
All Rough Inspection - Residential Failed 6/10/2020 6/10/2020 06/10/2020
Misc
Informational
04/13/2020
- GARAGE PORTAL FRAME HOLDDOWNS NAILED OFF, NAILING PATTERN, HEADER TO KING STUD STRAPS, 5/8 ANCHOR BOLTS & DOUBLE BOTTOM PLATE, OK TO COVER
Misc
Corrective Action Required
06/10/2020
- TIGHTEN ANCHOR BOLTS GARAGE & BASEMENT - - PROVIDE CS-PF PER PLAN PATIO DOOR - - FIRE BLOCK FIREPLACE IN CORNERS AT CEILING - - ADDRESS NOTCHED RIDGE ON HANGER ABOVE LIVING ROOM - - NO DECK PIER INSPECTION ON RECORD - : NOTE: HAMMER ARRESTOR IN WALL LAUNDRY :
All Rough Inspection - Residential Failed 6/16/2020 6/16/2020 06/16/2020
Misc
Informational
06/10/2020
- GARAGE PORTAL FRAME HOLDDOWNS NAILED OFF, NAILING PATTERN, HEADER TO KING STUD STRAPS, 5/8 ANCHOR BOLTS & DOUBLE BOTTOM PLATE, OK TO COVER
Misc
Corrective Action Required
06/10/2020
- ADDRESS NOTCHED RIDGE ON HANGER ABOVE LIVING ROOM LETTER FROM VAN DEURZEN NO CORRECTIVE ACTION REQUIRED - - NO DECK PIER INSPECTION ON RECORD : CORY TO PROVIDE ENGINEERS REPORTFOR FOUNDATION & DECK PIERS : WITHIN 48 HOURS OF POUR : - : NOTE: HAMMER ARRESTOR IN WALL LAUNDRY : - OK TO INSULATE - Michael Harkins 06/16/2020 8:23 AM
Piers/Caissons Inspection - Residential Passed 2/28/2020 06/16/2020
Misc
Informational
06/16/2020
- 3RD PARTY PIERS BY TODD LANGENHORST @ VAN DEURZEN SIGNED & SEALED BY CHAD STREETER - (41) 18" DEPTH 12-17' BEARING LIMESTONE - - HOUSE & DECK PIERS-
All Rough Inspection - Residential Passed 6/16/2020 06/16/2020
Misc
Informational
06/16/2020
- GARAGE PORTAL FRAME HOLDDOWNS NAILED OFF, NAILING PATTERN, HEADER TO KING STUD STRAPS, 5/8 ANCHOR BOLTS & DOUBLE BOTTOM PLATE, OK TO COVER
Misc
Informational
06/17/2020
: NOTE: HAMMER ARRESTOR IN WALL LAUNDRY : - OK TO INSULATE - Michael Harkins 06/16/2020 8:23 AM
Driveway Inspection Partial 7/22/2020 (P.M.) 7/22/2020 07/22/2020
Misc
Informational
07/22/2020
Forms were placed and aggregate was present and compacted. They also tore out the curbing in front of the approach. Curbing was removed joint to joint. Rebar was drilled into existing curbing for support. RP 7-22-20
Driveway Inspection Passed 7/31/2020 7/31/2020 07/31/2020
Misc
Informational
07/22/2020
Forms were placed and aggregate was present and compacted. They also tore out the curbing in front of the approach. Curbing was removed joint to joint. Rebar was drilled into existing curbing for support. RP 7-22-20
Misc
Informational
07/31/2020
Finished driveway and new curbing meets LS specs. RP 7-31-20
Plot Plan Inspection Passed 8/24/2020 08/24/2020
Occupancy Inspection - Codes Residential Failed 9/22/2020 9/22/2020 09/22/2020
Misc
Corrective Action Required
09/22/2020
-deficient erosion control. Must be in compliance within two days. -Remove debris from curb and gutter -Remove trash and construction debris -Final grade per approved plot and sod -Downspouts to discharge minimum 36” from the foundation -Remove paint covers from all smoke and carbon monoxide alarms -All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frame's exterior surface. The surface mounted bolt assembly shall be installed at the base of the door. -Missing crank levers at egress windows -Open box upstairs ceiling
Erosion Control Inspection Residential Failed 09/22/2020
Misc
Corrective Action Required
09/22/2020
-deficient erosion control. Must be in compliance within two days. -Remove debris from curb and gutter
Occupancy Inspection - Codes Residential Failed 9/30/2020 9/30/2020 09/30/2020
Misc
Corrective Action Required
09/22/2020
-Remove trash and construction debris from garage -Final grade per approved plot and sod -Downspouts to discharge minimum 36” from the foundation -Remove paint covers from all smoke and carbon monoxide alarms
Occupancy Inspection - Codes Residential Temporary C of O 10/1/2020 10/1/2020 10/01/2020
Misc
Corrective Action Required
09/30/2020
-Final grade per approved plot and sod
Occupancy Inspection - Codes Residential Full C of O 10/8/2020 10/8/2020 10/08/2020
Misc
Resolved
10/08/2020
-Final grade per approved plot and sod
Documents & Images
Date Uploaded File Type Document Name
02/11/2020 Letter Codes Residential Plan Review
02/18/2020 Receipt Receipt for transaction: 2020-000655
02/18/2020 Letter DS Building Permit
02/20/2020 Engineer Report/Study DOC022020-02202020091530
02/20/2020 Plot Plan DOC022020-02202020091545
03/02/2020 Letter INSPECTION SUMMARY
04/03/2020 Engineer Report/Study Final_2020.03.31_GBSlab_LSMO_Concrete Design
04/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/16/2020 Engineer Report/Study 156 NW Carson Dr_PIER INSP_2020-02-28
06/16/2020 Engineer Report/Study 156 NW Carson Drive_Framing Evaluation Report_6-15-20
06/16/2020 Engineer Report/Study 156 NW Carson Dr_PIER INSP_2020-02-28
06/17/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/31/2020 Letter INSPECTION SUMMARY
08/21/2020 Plot Plan As Graded Plot Plan
08/24/2020 Letter INSPECTION SUMMARY
09/22/2020 Letter INSPECTION SUMMARY
09/22/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter Codes Temporary Certificate of Occupancy
10/08/2020 Letter Codes Final Certificate of Occupancy
10/08/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home