Permit Application Status

PRRES20200067


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200067
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO - ROOF TRUSS PACKAGE
01/09/2020
01/13/2020
08/26/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 01/13/2020 01/09/2020
Jennifer Thompson
Plot Plan Review Approved 01/13/2020 01/09/2020
Dylan Eppert
Residential Plan Review Approved 01/13/2020 01/09/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,074.80 $1,074.80 Paid 01/13/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 01/13/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 01/13/2020
Water Meter Fee $425.02 $425.02 Paid 01/13/2020
Right of Way Permit Fee $80.00 $80.00 Paid 01/13/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/13/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/11/2020 02/11/2020
Sewer Service Inspection - R Failed 3/5/2020 3/5/2020 03/05/2020
Misc
Corrective Action Required
03/05/2020
- Uncover stub connection at main for inspection. Covered with gravel. -
Sewer Service Inspection - R Passed 3/6/2020 3/6/2020 03/06/2020
Misc
Resolved
03/06/2020
Water Service Inspection - R Passed 3/11/2020 03/11/2020
Underslab Plumbing Inspection - Residential Passed 3/18/2020 3/18/2020 03/18/2020
Piers/Caissons Inspection - Residential Passed 4/17/2020 (10:00) 4/17/2020 04/17/2020
Misc
Informational
04/17/2020
(2) 24 x 36 covered deck piers
Electrical Service Inspection Passed 6/18/2020 6/18/2020 06/17/2020
Gas Piping Inspection - Residential Passed 6/18/2020 6/18/2020 06/17/2020
Gas Service Inspection - Residential Passed 06/17/2020
All Rough Inspection - Residential Failed 6/18/2020 6/18/2020 06/17/2020
Misc
Corrective Action Required
06/17/2020
- Seal all top plate penetrations 1st floor - Address cut joist at HVAC chase in mud room - Nail off all joist hangers kitchen/living room lvl connection - Address joists bored for DWV above living room, cannot be bored closer than 2” to top and bottom of joist - Fireblock all tub and shower traps - Truss hangers per plans - Truss bracing per plan - Remove rear patio lid for truss hanger inspection - Joist framing above garage per plans - triple joists missing - Steel column at garage beam per plans - Support at protect pex at showers - Fix snow block 2nd floor bed - EC#2 hold down per plan 2nd floor - Protection plates at all NM within 1 1/4” of end of framing member - (2) 2x10 header at egress window basement per plans
All Rough Inspection - Residential Failed 6/24/2020 6/24/2020 06/24/2020
Misc
Corrective Action Required
06/17/2020
- Address joists bored for DWV above living room, cannot be bored closer than 2” to top and bottom of joist - complete DWV based upon engineer letter - Truss hangers per plans - garage , unable to check 2nd floor, truss layout for 2nd floor not in packet - Truss bracing per plan - unable to check 2nd floor, truss layout missing for 2nd floor - Support and protect pex at showers - EC#2 hold down per plan 2nd floor - master bed, bed #2, stairway above entry
All Rough Inspection - Residential Failed 6/25/2020 6/25/2020 06/25/2020
Misc
Corrective Action Required
06/24/2020
- Truss hangers per plans - garage TJC37
All Rough Inspection - Residential Passed 06/25/2020
Misc
Resolved
06/25/2020
Driveway Inspection Passed 7/10/2020 7/10/2020 07/13/2020
Misc
Informational
07/13/2020
On Friday, 7-10-2020. A inspection was completed and forms and sub-grade was passed to pour concrete driveway. On 7-13-2020, a visual inspection of the finished drive was conducted and Passes inspection.
Occupancy Inspection - Codes Residential Failed 8/13/2020 8/13/2020 08/13/2020
Misc
Corrective Action Required
08/13/2020
- Complete final grade and sod - Guardrail required at front steps, more than 30” from grade - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Seal all penetrations through siding, seal along top of AC disconnect - Handrail required at steps back porch, 4 rises - Obtain lawn irrigation system permit - GFCI protection required at laundry receptacle - GFCI protection required at dishwasher receptacle - Security screws, provide (2) 3” screws each exterior hinge and strike plate back door
Plot Plan Inspection Passed 08/25/2020
Occupancy Inspection - Codes Residential Failed 8/25/2020 8/25/2020 08/25/2020
Misc
Corrective Action Required
08/13/2020
- Water meter lid should be even with grade, adjust grade and or water meter height
Occupancy Inspection - Codes Residential Full C of O 8/26/2020 8/26/2020 08/26/2020
Misc
Resolved
08/26/2020
Documents & Images
Date Uploaded File Type Document Name
01/13/2020 Receipt Receipt for transaction: 2020-000144
01/13/2020 Letter DS Building Permit
01/13/2020 Plot Plan DOC011320-01132020133508
02/11/2020 Letter INSPECTION SUMMARY
03/05/2020 Letter INSPECTION SUMMARY
03/06/2020 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
03/18/2020 Letter INSPECTION SUMMARY
04/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/23/2020 69 Hawthorne Ridge Floor Joist Holes Letter
06/24/2020 Letter INSPECTION SUMMARY
06/24/2020 69 Hawthorne Ridge End Conditions #2 Letter
06/25/2020 Letter INSPECTION SUMMARY
06/25/2020 Letter INSPECTION SUMMARY
08/13/2020 Letter INSPECTION SUMMARY
08/25/2020 Letter INSPECTION SUMMARY
08/25/2020 Letter INSPECTION SUMMARY
08/26/2020 Letter Field Certificate of Occupancy
08/26/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home