Summary
PRRES20193356
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED PATIO - UNFINISHED BASEMENT
11/14/2019
11/19/2019
08/21/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/18/2019 11/19/2019
Dylan Eppert
Sidewalks
Corrective Action Required
11/15/2019

Sidewalks with dimensions must be provided on the plot plan. SIDEWALK ON NORTH SIDE SHOWS 5' NOT 4' ON PLAT.
As-graded plot plan
Corrective Action Required
11/15/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 11/18/2019 11/15/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,280.84 $1,280.84 Paid 11/19/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 11/19/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/19/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/19/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/19/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/19/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/10/2019 12/10/2019
Underslab Plumbing Inspection - Residential Failed 1/17/2020 1/17/2020 01/17/2020
Misc
Corrective Action Required
01/17/2020
Drain tile needs to be set around foundation
Underslab Plumbing Inspection - Residential Failed 1/21/2020 1/21/2020 01/21/2020
Misc
Corrective Action Required
01/17/2020
Drain tile needs to be set around foundation, all underslab plumbing is covered up. Uncover and call in when ready
Underslab Plumbing Inspection - Residential Failed 2/3/2020 2/3/2020 02/03/2020
Misc
Corrective Action Required
01/21/2020
Drain tile needs to be complete set around foundation Under slab plumbing submerged in water and mud, unable to perform inspection
Underslab Plumbing Inspection - Residential Passed 2/7/2020 2/7/2020 02/07/2020
Misc
Resolved
02/07/2020
Piers/Caissons Inspection - Residential Passed 3/17/2020 (10:30) 3/17/2020 03/17/2020
Misc
Informational
03/17/2020
(2) 24 x 36 piers
Sewer Service Inspection - R Passed 4/1/2020 (1:00) 4/1/2020 04/01/2020
Water Service Inspection - R Partial 4/7/2020 04/07/2020
Water Service Inspection - R Passed 4/8/2020 4/8/2020 04/08/2020
Gas Piping Inspection - Residential Passed 4/22/2020 04/22/2020
Electrical Service Inspection Passed 4/22/2020 04/22/2020
Gas Service Inspection - Residential Passed 4/22/2020 4/22/2020 04/22/2020
All Rough Inspection - Residential Failed 4/22/2020 4/22/2020 04/22/2020
Misc
Corrective Action Required
04/22/2020
- PROVIDE 800LB HOLDDOWNS PER PLAN EC#2 - - PROVIDE PFH PORTAL FRAMING GARAGE DOOR PER PLAN - - PROVIDE MISSING TRUSS HANGERS PER TRUSS LAYOUT SCHEDULE - - SEAL UPWARD PENETRATIONS AT TOP PLATE @ CLOSET BED #2 &NPLUMBING & ELECTRICAL GARAGE - PROVIDE BOCA PLATES PLUMBING MASTER TUB - - SEAL FIRE BLOCK AT CHASE GREAT ROOM - - NAIL SHEATHING AT STAIRWAY -
All Rough Inspection - Residential Failed 4/30/2020 4/30/2020 04/30/2020
Misc
Corrective Action Required
04/22/2020
- PROVIDE 800LB HOLDDOWNS PER PLAN EC#2 - 2ND FLOOR MASTER BED, BED #2 - SEAL UPWARD PENETRATIONS AT TOP PLATE @ CLOSET BED #2 &NPLUMBING & ELECTRICAL GARAGE
Driveway Inspection Partial 5/6/2020 5/6/2020 05/06/2020
Misc
Informational
05/06/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 5/7/2020 5/7/2020 05/07/2020
Misc
Corrective Action Required
04/30/2020
- PROVIDE 800LB HOLDDOWNS PER PLAN EC#2 - 2ND FLOOR BED #2 - SEAL UPWARD PENETRATIONS AT TOP PLATE @ ELECTRICAL GARAGE - REESTABLISH EROSION CONTROL AT LOT, MUD AND GRAVEL IN STREET- RESOLVE BEFORE RE INSPECTION -
Erosion Control Inspection Residential Failed 5/7/2020 05/07/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/07/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/07/2020
Misc
Corrective Action Required
05/07/2020
CLEAN MUD AND GRAVEL IN STREET
All Rough Inspection - Residential Passed 5/8/2020 5/8/2020 05/08/2020
Misc
Resolved
05/08/2020
Erosion Control Inspection Residential Failed 5/8/2020 05/08/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/08/2020
Misc
Corrective Action Required
05/07/2020
SILT FENCE HAS BEEN INSTALLED ALONG FRONT OF LOT. MUD AND GRAVEL ARE STILL PRESENT IN STREET FROM LOT AND NEEDS TO BE CLEANED
Driveway Inspection Passed 5/11/2020 05/12/2020
Misc
Informational
05/06/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Erosion Control Inspection Residential Failed 5/13/2020 05/13/2020
Misc
Resolved
05/13/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/13/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN MUD AND GRAVEL IN STREET
Occupancy Inspection - Codes Residential Failed 6/24/2020 6/24/2020 06/24/2020
Misc
Corrective Action Required
06/24/2020
- Submit as graded plot plan for review - Complete final grade and sod - Terminate and complete exterior lighting outside garage, back patio - Complete stone/siding at garage - Guardrail at front porch, more than 30” from grade - GFCI protection required at exterior outlet front porch - Either complete or remove exposed electrical for AC at exterior - Seal all penetrations in siding, seal along top of AC disconnect, meter can - Complete ceiling light in dining room - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Security screws at back door, provide (2) 3” screws each exterior hinge and strike plate - GFCI outlet testing incorrect at kitchen counter by stove, garage - Terminate and complete lighting in basement - Remove all paint covers from smokes - 2nd floor bath, no current at GFCI receptacles to test - Complete tub tile at 2nd floor master bath
Occupancy Inspection - Codes Residential Temporary C of O 6/29/2020 6/29/2020 06/29/2020
Misc
Corrective Action Required
06/24/2020
- Submit as graded plot plan for review - Complete final grade and sod - Guardrail at front porch, more than 30” from grade - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” OK for TCO
Plot Plan Inspection Passed 08/21/2020
Occupancy Inspection - Codes Residential Full C of O 8/21/2020 8/21/2020 08/21/2020
Misc
Resolved
08/21/2020
Documents & Images
Date Uploaded File Type Document Name
11/15/2019 Letter Codes Residential Plan Review
11/19/2019 Receipt Receipt for transaction: 2019-007377
11/19/2019 Letter DS Building Permit
11/21/2019 Plot Plan DOC112019-11202019153858
12/10/2019 Letter INSPECTION SUMMARY
01/17/2020 Letter INSPECTION SUMMARY
01/21/2020 Letter INSPECTION SUMMARY
02/03/2020 Letter INSPECTION SUMMARY
02/07/2020 Letter INSPECTION SUMMARY
03/17/2020 Letter INSPECTION SUMMARY
04/01/2020 Letter INSPECTION SUMMARY
04/07/2020 Letter INSPECTION SUMMARY
04/08/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
04/30/2020 Letter INSPECTION SUMMARY
05/06/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter Braced Wall Revisions
05/08/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter Codes Temporary Certificate of Occupancy
08/20/2020 Plot Plan APPROVED AS-BUILT
08/21/2020 Letter INSPECTION SUMMARY
08/21/2020 Letter Field Certificate of Occupancy
08/21/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home