Permit Application Status

PRRES20192732


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192732
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT COVERED DECK
09/23/2019
12/30/2019
03/24/2020
04/06/2020
Locations
Contacts
SIGNATURE BUILDERS KC LLC, Address:1516 SW HOOK RD, Phone:(816) 215-0891  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
bill@sb-kc.net  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/07/2019 10/03/2019
Steve Conrick
Residential Plan Review Approved 10/07/2019 10/03/2019
Steve Conrick
06 Designate use of each room or space
Corrective Action Required
10/03/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. CLEAN UP LINEWORK IN BASEMENT AND 1ST AND 2ND FLOORS TO CLEARIFY ROOM DESIGNINATION. (I.E. KITCHEN AND UPSTAIRS BATHROOM ARE OVERLAPING ON SHEET A105)
07 Identify emergency escape openings from bedrooms
Corrective Action Required
10/03/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/03/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) ADD COMBO DETECTOR NEAR ADDIE'S ROOM ON SHEET A106
10 Combustion air
Corrective Action Required
10/03/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
10/03/2019

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
10/03/2019

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
10/03/2019

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 09/25/2019 09/25/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
09/24/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
City infrustructure
Corrective Action Required
09/24/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. CALL OUT FIELD INLET WITH TOP AND WEIR ELEVATION
Drainage swales
Corrective Action Required
09/24/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provideD
Lot elevations
Corrective Action Required
09/24/2019

Existing and finish elevations at all property corners must be provided on the plot plan. VERIFY LOT CORNER ELEVATIONS ARE CORRECT. THEY ARE SHOWN DIFFERENT THAT WHAT IS ON THE MOST RECENT AS-GRADED MDP
Residential Plan Review Rejected 09/25/2019 09/23/2019
Steve Conrick
06 Designate use of each room or space
Corrective Action Required
09/23/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. CLEAN UP LINEWORK IN BASEMENT AND 1ST AND 2ND FLOORS TO CLEARIFY ROOM DESIGNINATION. (I.E. KITCHEN AND UPSTAIRS BATHROOM ARE OVERLAPING ON SHEET A105)
07 Identify emergency escape openings from bedrooms
Corrective Action Required
09/23/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
09/23/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) ADD COMBO DETECTOR NEAR ADDIE'S ROOM ON SHEET A106
10 Combustion air
Corrective Action Required
09/23/2019

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
11 Designate R-value(s) for floors, walls, ceilings, roof/ceilings.
Corrective Action Required
09/23/2019

Designate R-value(s) for floors, walls, ceilings, roof/ceilings. (LSCO 7-802)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
09/23/2019

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
09/23/2019

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,244.03 $1,244.03 Paid 10/07/2019
Right of Way Permit Fee $80.00 $80.00 Paid 10/07/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/07/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 10/07/2019
Water Meter Fee $425.02 $425.02 Paid 10/07/2019
8331507-Sewer Connection Fee $510.00 $510.00 Paid 10/07/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection - R Partial 11/11/2019 11/11/2019 11/11/2019
Underslab Plumbing Inspection - Residential Partial 11/12/2019 11/12/2019 11/11/2019
Sewer Service Inspection - R Partial 11/11/2019 11/11/2019 11/11/2019
Sewer Service Inspection - R Passed 11/14/2019 11/14/2019 11/14/2019
Underslab Plumbing Inspection - Residential Failed 11/15/2019 11/15/2019
Misc
Resolved
11/15/2019
All work covered up, uncover pipe to perform inspection
Water Service Inspection - R Passed 11/15/2019 11/15/2019 11/15/2019
Underslab Plumbing Inspection - Residential Passed 11/15/2019 11/15/2019
Misc
Corrective Action Required
11/15/2019
All work covered up, uncover pipe to perform inspection
Electrical Service Inspection Failed 1/8/2020 1/8/2020 01/08/2020
Misc
Corrective Action Required
01/08/2020
ELECTRICAL PANEL NEEDS TO BE BONDED
Gas Piping Inspection - Residential Passed 1/8/2020 1/8/2020 01/08/2020
All Rough Inspection - Residential Failed 1/8/2020 1/8/2020 01/08/2020
Misc
Corrective Action Required
01/08/2020
<<Install plumbing plates master closet <<Solid block floor joists at all bearing locations throughout <<Install double perlins per plan at attic over hallway. <<2nd floor plan shows 2x6 walls. Install 2x6 wall on 2nd floor or revise plans. <<support all dwv throughout at 48” o.c. <<Reinstall missing blocks at cantilever locations in basement <<No top plate connection at front entryway tall walls. Install straps to tie tall walls to perpendicular walls.
Gas Service Inspection - Residential Passed 1/10/2020 1/10/2020 01/10/2020
All Rough Inspection - Residential Failed 1/10/2020 1/10/2020 01/10/2020
Misc
Corrective Action Required
01/10/2020
please fur out the HVAC on the garage side for the Energy code . min 3" insulation needed. ok to insulate
Electrical Service Inspection Passed 1/10/2020 1/10/2020 01/10/2020
Driveway Inspection Partial 1/13/2020 1/13/2020 01/13/2020
Misc
Informational
01/13/2020
Forms were placed and aggregate was present and compacted. Talked with Wilson from Concrete Solutions. Gave him the print out of our specs, which he was asking for. He will be using KCMMB mix and white cure. RP 1-13-19
All Rough Inspection - Residential Passed 1/14/2020 1/14/2020 01/14/2020
Misc
Resolved
01/14/2020
ok to insulate
Erosion Control Inspection Residential Failed 1/14/2020 01/14/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/14/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Driveway Inspection Passed 1/27/2020 02/03/2020
Misc
Informational
02/03/2020
Finished driveway meets LS specs. RP 2-3-20
Erosion Control Inspection Residential Failed 3/24/2020 03/24/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/24/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - provide silt fence at street
Occupancy Inspection - Codes Residential Failed 3/24/2020 3/24/2020 03/24/2020
Misc
Corrective Action Required
03/24/2020
- provide as graded plot plan - no footing inspection on record - provide irrigation permit - provide guardrail or raise grade to 30” front porch - provide final grade, sod, down spouts - AFCI breaker not working master & upper middle bedroom - shear set screw on anti siphon device at main - provide GFCI protection dish washer - provide (2) 3” screws each exterior hinge & strike plate garage door - install faucet & p trap bath at garage door - GFCI at rear garage door not working - seal exterior penetrations, top of meter can, A/C disconnect
Footing Inspection - Residential Passed 4/1/2020 04/01/2020
Occupancy Inspection - Codes Residential Failed 4/1/2020 4/1/2020 04/01/2020
Misc
Corrective Action Required
03/24/2020
- provide as graded plot plan - provide irrigation permit - - AFCI breaker not working master
Plot Plan Inspection Passed 4/7/2020 04/06/2020
Occupancy Inspection - Codes Residential Full C of O 4/6/2020 04/06/2020
Misc
Resolved
04/06/2020
Documents & Images
Date Uploaded File Type Document Name
09/24/2019 Letter Codes Residential Plan Review
10/07/2019 Receipt Receipt for transaction: 2019-006652
11/11/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
11/14/2019 Letter INSPECTION SUMMARY
11/15/2019 Letter INSPECTION SUMMARY
11/15/2019 Letter INSPECTION SUMMARY
12/30/2019 Letter DS Building Permit
12/30/2019 Plot Plan DOC123019-002
01/08/2020 Letter INSPECTION SUMMARY
01/08/2020 Letter INSPECTION SUMMARY
01/08/2020 Letter INSPECTION SUMMARY
01/10/2020 Engineer Report/Study Engineer Letter (Permit #PRRES20192732)
01/10/2020 Letter INSPECTION SUMMARY
01/10/2020 Letter INSPECTION SUMMARY
01/13/2020 Letter INSPECTION SUMMARY
01/14/2020 Letter INSPECTION SUMMARY
01/14/2020 Letter INSPECTION SUMMARY
02/03/2020 Letter INSPECTION SUMMARY
03/24/2020 Letter INSPECTION SUMMARY
03/24/2020 Letter INSPECTION SUMMARY
03/24/2020 Footing Inspection
03/24/2020 Plot Plan
03/24/2020 Footing Inspection
03/24/2020 Sprinkler Permit
03/24/2020 Sprinkler Permit Receipt
04/01/2020 Letter INSPECTION SUMMARY
04/05/2020 Lot #1439 As Graded Plot Plan
04/05/2020 Lot #1439 Irrigation Permit
04/05/2020 Lot #1439 Irrigation Permit Payment Receipt
04/06/2020 Letter Lot #1439 As Graded Plot Plan
04/06/2020 Letter Lot #1439 Irrigation Permit Payment Receipt
04/06/2020 Letter Lot #1439 Irrigation Permit
04/06/2020 Letter Codes Final Certificate of Occupancy
04/06/2020 Letter Field Certificate of Occupancy
04/06/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home