Summary
PRRES20192443
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
08/30/2019
09/04/2019
06/08/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/04/2019 09/04/2019
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
08/30/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No smoke detector shown in basement and bedroom #4
Plot Plan Review Approved 09/04/2019 09/04/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,135.08 $1,135.08 Paid 09/04/2019
Right of Way Permit Fee $80.00 $80.00 Paid 09/04/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/04/2019
8331507-Sewer Connection Fee $480.00 $480.00 Paid 09/04/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 09/04/2019
Water Meter Fee $425.02 $425.02 Paid 09/04/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/13/2019 (11:30) 9/13/2019 09/13/2019
Sewer Service Inspection - R Passed 10/1/2019 10/01/2019
Water Service Inspection - R Passed 10/2/2019 (11:00) 10/2/2019 10/02/2019
Underslab Plumbing Inspection - Residential Passed 10/16/2019 10/16/2019 10/16/2019
All Rough Inspection - Residential Failed 1/10/2020 1/10/2020 01/10/2020
Misc
Corrective Action Required
01/10/2020
-properly nail trusses to truss hangers, east wall in office/flex room - secure gas line to fire place - secure fireplace to framing - anchor beam posts throughout house - proper washer needs to be installed on east side hold down bolt in garage - garage portal straps need to be installed - hurricane straps missing on south side, second floor - vent pipe above bedroom #4 not being properly supported - double joist hanger needed, north side of basement Ok to insulate
Gas Piping Inspection - Residential Passed 1/10/2020 1/10/2020 01/10/2020
Electrical Service Inspection Passed 1/10/2020 1/10/2020 01/10/2020
All Rough Inspection - Residential Failed 1/16/2020 1/16/2020 01/16/2020
Misc
Corrective Action Required
01/10/2020
-properly nail trusses to truss hangers, east wall in office/flex room - secure gas line to fire place - secure fireplace to framing - anchor beam posts throughout house - proper washer needs to be installed on east side hold down bolt in garage - garage portal straps need to be installed - hurricane straps missing on south side, second floor - vent pipe above bedroom #4 not being properly supported - double joist hanger needed, north side of basement Ok to insulate No key in lock box, no access, no contact info
All Rough Inspection - Residential Passed 1/17/2020 1/17/2020 01/17/2020
Misc
Resolved
01/17/2020
Driveway Inspection Partial 3/2/2020 3/2/2020 03/02/2020
Misc
Informational
03/02/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/6/2020 03/11/2020
Misc
Informational
03/02/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 5/21/2020 5/21/2020 05/21/2020
Miscellaneous Correction
Corrective Action Required
05/21/2020
-MAINTAIN EROSION CONTROL -FINAL GRADE AND SOD -POVIDE SPLASH BLOCKS OR PROPER DRAINAGE AWAY FROM FOUNDATION -PROVIDE GAURD RAIL AT FRONT PORCH WHERE ABOVE 30” -ADJUST SELF CLOSING GARAGE DOOR TO LATCH PROPERLY -TIGHTEN NUTS ON ANCHOR BOLTS FOR CLOMNS IN BASEMENT -REMOVE SMOKE DETECTOR COVERS -HANDRAIL IN BASEMENT STAIRS MUST EXTEND TO ABOVE LOWEST RISER AND TERMINATE IN NEWELL POST OR SAFETY TERMINAL
Plot Plan Inspection Passed 06/08/2020
Occupancy Inspection - Codes Residential Full C of O 6/8/2020 6/8/2020 06/08/2020
Miscellaneous Correction
Resolved
06/08/2020
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home