Permit Application Status

PRRES20192007


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192007
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT
07/25/2019
08/01/2019
04/02/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/29/2019 08/01/2019
Steve Conrick
Rear yard dimension
Corrective Action Required
07/29/2019

The rear yard demision(s) must be provided on the plot plan. *Rear yard setback is 30'
As-graded plot plan
Corrective Action Required
07/29/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *add note "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Approved 07/30/2019 07/26/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,033.02 $1,033.02 Paid 08/01/2019
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 08/01/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 08/01/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 08/01/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 08/01/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/01/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/01/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 8/22/2019 8/22/2019 08/22/2019
Water Service Inspection - R Passed 8/23/2019 8/23/2019 08/23/2019
Underslab Plumbing Inspection - Residential Passed 8/29/2019 8/29/2019 08/29/2019
Gas Service Inspection - Residential Passed 10/28/2019 10/28/2019 10/28/2019
Gas Piping Inspection - Residential Passed 10/28/2019 10/28/2019 10/28/2019
Electrical Service Inspection Passed 10/28/2019 10/28/2019 10/28/2019
All Rough Inspection - Residential Failed 10/28/2019 10/28/2019 10/29/2019
Misc
Corrective Action Required
10/29/2019
-Fire block double walls in basement vertically - protect plumbing and waterlines in downstairs basement bathroom at top plate - protect piping at bottom plate in pantry -ok to insulate
All Rough Inspection - Residential Failed 10/31/2019 10/31/2019 10/31/2019
Misc
Corrective Action Required
10/29/2019
-Fire block double walls in basement vertically - protect plumbing and waterlines in downstairs basement bathroom at top plate -ok to insulate
All Rough Inspection - Residential Failed 11/4/2019 11/4/2019 11/04/2019
Misc
Corrective Action Required
10/31/2019
- protect plumbing and waterlines in downstairs basement bathroom at top plate -ok to insulate
All Rough Inspection - Residential Passed 11/5/2019 11/5/2019 11/05/2019
Misc
Resolved
11/05/2019
Driveway Inspection Partial 11/18/2019 (Ready Now) 11/18/2019 11/18/2019
Misc
Informational
11/18/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 11/25/2019 12/09/2019
Misc
Informational
11/18/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 1/29/2020 1/29/2020 01/29/2020
Misc
Corrective Action Required
01/29/2020
- Secure oven with anti tip device - GFCI protection required at washing machine outlet - Main water line, shear off set screw on anti siphon - Hot water heater discharge line minimum distance to floor 2x discharge pipe diameter up to 6” maximum - Seal around exterior light fixtures - Place splash blocks at gutter down spouts and sump pump discharge. Minimum distance 3’ from foundation - Submit as graded plot plan for review prior to sod placement - Complete final grade and place sod
Occupancy Inspection - Codes Residential Not Ready 1/30/2020 1/30/2020 01/30/2020
Misc
Corrective Action Required
01/29/2020
- Secure oven with anti tip device - GFCI protection required at washing machine outlet - Main water line, shear off set screw on anti siphon - Hot water heater discharge line minimum distance to floor 2x discharge pipe diameter up to 6” maximum - Seal around exterior light fixtures - Place splash blocks at gutter down spouts and sump pump discharge. Minimum distance 3’ from foundation - Submit as graded plot plan for review prior to sod placement - Complete final grade and place sod - Lock box code not provided. Unable to perform inspection.
Occupancy Inspection - Codes Residential Temporary C of O 1/30/2020 01/30/2020
Misc
Corrective Action Required
01/30/2020
- Seal around exterior light fixtures - Place splash blocks at gutter down spouts and sump pump discharge. Minimum distance 3’ from foundation - Submit as graded plot plan for review prior to sod placement - Complete final grade and place sod - No footing inspection on file as being completed. Please provide engineer report. Ok for TCO
Occupancy Inspection - Codes Residential Failed 3/30/2020 03/30/2020
Misc
Corrective Action Required
01/30/2020
- Seal around exterior light fixtures ( NOT DONE ) - Place splash blocks at gutter down spouts and sump pump discharge. Minimum distance 3’ from foundation - Submit as graded plot plan for review prior to sod placement ( NO AS GRADED PLOT PLAN IN DOCUMENTS) - Complete final grade and place sod - No footing inspection on file as being completed. Please provide engineer report ( NO FOOTING IN DOCUMENTS). Ok for TCO < (NO DECK PIER INSPECTION BY LS)> < ( SIDEWALK STILL PENDING)>
Footing Inspection - Residential Passed 8/12/2019 04/01/2020
Occupancy Inspection - Codes Residential Failed 4/2/2020 4/2/2020 04/02/2020
Misc
Corrective Action Required
03/30/2020
- Complete and place sod - . Ok for TCO < (NO DECK PIER INSPECTION BY LS)>
Plot Plan Inspection Passed 4/2/2020 04/02/2020
Occupancy Inspection - Codes Residential Full C of O 4/2/2020 04/02/2020
Misc
Resolved
04/02/2020
Documents & Images
Date Uploaded File Type Document Name
07/29/2019 Letter Codes Residential Plan Review
08/01/2019 Receipt Receipt for transaction: 2019-005255
08/01/2019 Letter DS Building Permit
08/02/2019 Plot Plan DOC080219-08022019103838
08/22/2019 Letter INSPECTION SUMMARY
08/29/2019 Letter INSPECTION SUMMARY
08/29/2019 Letter INSPECTION SUMMARY
10/28/2019 Letter INSPECTION SUMMARY
10/28/2019 Letter INSPECTION SUMMARY
10/28/2019 Letter INSPECTION SUMMARY
10/29/2019 Letter INSPECTION SUMMARY
10/31/2019 Letter INSPECTION SUMMARY
11/04/2019 Letter INSPECTION SUMMARY
11/05/2019 Letter INSPECTION SUMMARY
11/05/2019 Letter INSPECTION SUMMARY
11/18/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
01/29/2020 Letter INSPECTION SUMMARY
01/30/2020 Letter INSPECTION SUMMARY
01/30/2020 Letter Codes Temporary Certificate of Occupancy
03/30/2020 Letter INSPECTION SUMMARY
04/01/2020 Plot Plan LOT 57 ASBUILT
04/01/2020 Letter 57 Stoney Creek footing
04/01/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter Codes Final Certificate of Occupancy
04/02/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home