Permit Application Status

PRRES20191612


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191612
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
06/21/2019
06/26/2019
05/22/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 06/25/2019 06/26/2019
Dylan Eppert
Plot Plan Review Approved 06/25/2019 06/25/2019
Steve Conrick
Residential Plan Review Approved 06/25/2019 06/21/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,039.12 $1,039.12 Paid 06/26/2019
8331507-Sewer Connection Fee $450.00 $450.00 Paid 06/26/2019
Water Tap Fee $3,409.00 $3,409.00 Paid 06/26/2019
Water Meter Fee $408.37 $408.37 Paid 06/26/2019
Right of Way Permit Fee $80.00 $80.00 Paid 06/26/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/26/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/15/2019 (1:00) 7/15/2019 at 1:30 PM 07/15/2019
Sewer Service Inspection - R Passed 8/8/2019 8/8/2019 at 11:00 AM 08/08/2019
Water Service Inspection - R Passed 8/9/2019 8/9/2019 at 3:06 PM 08/09/2019
Underslab Plumbing Inspection - Residential Passed 8/13/2019 8/13/2019 at 7:15 AM 08/13/2019
Piers/Caissons Inspection - Residential Passed 9/13/2019 (9:00) 9/13/2019 09/13/2019
All Rough Inspection - Residential Failed 10/15/2019 10/15/2019 10/15/2019
Misc
Corrective Action Required
10/15/2019
- Hurricane straps needed in garage - 2 additional GFCI outlets in needed garage - joist hangers needed at both ends of floor joist on south side, near kitchen - protect piping at bottom plate, south side bump-out in kitchen - fire block at top plate, east side fir out for piping and waterlines in main living area - secure gas line for fire place - clothes dryer vent needs to be in a 2x6 wall or code compliant, 2018 code cycle has changed this detail on where the vent can be installed - hurricane straps needed in master closet, east side - not enough pressure in gauge for gas service - north side basement double wall needs to be fire blocked - additional 2x4 needs to be added to right side of stairs, going to basement. As per plan - secure fireplace to framing -
Electrical Service Inspection Passed 10/15/2019 10/15/2019 10/15/2019
Gas Piping Inspection - Residential Passed 10/15/2019 10/15/2019 10/15/2019
Gas Service Inspection - Residential Failed 10/15/2019
Misc
Corrective Action Required
10/15/2019
Not enough gas pressure to perform inspection
All Rough Inspection - Residential Failed 10/18/2019 10/18/2019 10/18/2019
Misc
Partial Correction
10/18/2019
- Hurricane straps needed in garage - 2 additional GFCI outlets in needed garage - joist hangers needed at both ends of floor joist on south side, near kitchen - protect piping at bottom plate, south side bump-out in kitchen - fire block at top plate, east side fir out for piping and waterlines in main living area - secure gas line for fire place - clothes dryer vent needs to be in a 2x6 wall or code compliant, 2018 code cycle has changed this detail on where the vent can be installed - hurricane straps needed in master closet, east side - not enough pressure in gauge for gas service - north side basement double wall needs to be fire blocked - additional 2x4 needs to be added to right side of stairs, going to basement. As per plan - secure fireplace to framing -
Misc
Corrective Action Required
10/18/2019
** clothes dryer vent needs to be in a 2x6 wall or code compliant, 2018 code cycle has changed this detail on where the vent can be installed. Dryer duct is to be a 4” ROUND duct it can not be DISTORTED . ** Okay to insulate **
Gas Service Inspection - Residential Passed 10/18/2019
Misc
Resolved
10/18/2019
Not enough gas pressure to perform inspection
All Rough Inspection - Residential Passed 10/24/2019 10/24/2019 10/24/2019
Misc
Resolved
10/24/2019
Misc
Resolved
10/24/2019
** clothes dryer vent needs to be in a 2x6 wall or code compliant, 2018 code cycle has changed this detail on where the vent can be installed. Dryer duct is to be a 4” ROUND duct it can not be DISTORTED . ** Okay to insulate ** Resolved
Driveway Inspection Partial 2/10/2020 2/10/2020 02/10/2020
Misc
Informational
02/10/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 2/17/2020 02/18/2020
Misc
Resolved
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/11/2020 3/11/2020 03/11/2020
Misc
Corrective Action Required
09/17/2019
-Adjust water meter well to match final grade. - provide final grade, sod, splash blocks - provide 3 GFCI receptacles in garage - provide GFCI protection dishwasher & washing machine - provide guardrail or raise grade to 30” front porch - exhaust fan master water closet not working - provide lockout at service panel for hood microwave - provide (2) 3” screws each exterior hinge and strike plate patio door
Occupancy Inspection - Codes Residential Failed 4/23/2020 4/23/2020 04/23/2020
Misc
Corrective Action Required
03/11/2020
- Obtain lawn irrigation system permit and submit backflow certification - - Handrail required at back patio stairs, 4 rises-
Occupancy Inspection - Codes Residential Failed 5/4/2020 5/4/2020 05/04/2020
Misc
Corrective Action Required
05/04/2020
- OBTAIN LAWN IRRIGATION SYSTEM PERMIT AND SUBMIT BACKFLOW CERTIFICATION -
Plot Plan Inspection Passed 5/4/2020 05/04/2020
Occupancy Inspection - Codes Residential Full C of O 5/22/2020 5/22/2020 05/22/2020
Misc
Resolved
05/22/2020
Documents & Images
Date Uploaded File Type Document Name
06/26/2019 Receipt Receipt for transaction: 2019-004198
06/26/2019 Letter Codes Building Permit
06/26/2019 Plot Plan DOC062619-06262019151619
07/15/2019 Letter INSPECTION SUMMARY
08/08/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/13/2019 Letter INSPECTION SUMMARY
09/13/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/18/2019 Letter INSPECTION SUMMARY
10/18/2019 Letter INSPECTION SUMMARY
10/24/2019 Letter INSPECTION SUMMARY
02/10/2020 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
04/23/2020 Letter INSPECTION SUMMARY
05/04/2020 Letter INSPECTION SUMMARY
05/04/2020 Letter INSPECTION SUMMARY
05/22/2020 Letter Field Certificate of Occupancy
05/22/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home