Permit Application Status

PRRES20191464


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191464
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/06/2019
06/11/2019
05/11/2020
Locations
Contacts
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
BLUE VALLEY HEATING & COOLING LLC, Address:P O BOX 241, Phone:(816) 867-5122  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVE@DAVERICHARDSHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/10/2019 06/10/2019
Steve Conrick
Residential Plan Review Approved 06/10/2019 06/07/2019
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
06/06/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) no square footage shown for the covered deck
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
06/06/2019

Specification of rafter ties or ridge beam design. (IRC Section 802.3.1)
Miscellaneous Correction
Corrective Action Required
06/06/2019

The address on the plans show 1112 NE Goshen Dr when it should be 1112 NE Goshen Ct,
Misc
Corrective Action Required
06/06/2019

Braced wall table on page 6 references the 2012 code book when it should reference the 1018 code book.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $969.14 $969.14 Paid 06/11/2019
Right of Way Permit Fee $80.00 $80.00 Paid 06/11/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/11/2019
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/11/2019
Water Tap Fee $3,409.00 $3,409.00 Paid 06/11/2019
Water Meter Fee $408.37 $408.37 Paid 06/11/2019
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 6/28/2019 6/28/2019 at 11:05 AM 06/28/2019
Water Service Inspection - R Partial 6/28/2019 at 11:15 AM 06/28/2019
Misc
Partial Correction
06/28/2019
OK TO COVER PEX WATER LINE FROM BUILDING ENTRY AT NE CORNER OF HOUSE TO NEAR SE CORNER. WATER LINE TAP NOT COMPLETED BY LSWU DUE TO MAIN NOT ACTIVE. TAP, BORE, EXTENSION TO METER LOCATION NOT COMPLETED PRESENTLY. CALL FOR INSPECTION WHEN TAP, PEX AND COPPER PIPING, AND METER WELL ARE COMPLETED AND EXPOSED FOR INSPECTION.
Erosion Control Inspection Residential Failed 7/2/2019 07/02/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/02/2019
INSTALL EROSION CONTROL ALONG EAST SIDE OF LOT. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 7/2/2019 7/2/2019 at 8:30 AM 07/02/2019
All Rough Inspection - Residential Partial 8/1/2019 8/1/2019 08/01/2019
Misc
Corrective Action Required
08/01/2019
Portal strap and framing ok
Water Service Inspection - R Passed 8/1/2019 at 2:45 PM 08/01/2019
Misc
Resolved
08/01/2019
OK TO COVER PEX WATER LINE FROM BUILDING ENTRY AT NE CORNER OF HOUSE TO NEAR SE CORNER. WATER LINE TAP NOT COMPLETED BY LSWU DUE TO MAIN NOT ACTIVE. TAP, BORE, EXTENSION TO METER LOCATION NOT COMPLETED PRESENTLY. CALL FOR INSPECTION WHEN TAP, PEX AND COPPER PIPING, AND METER WELL ARE COMPLETED AND EXPOSED FOR INSPECTION.
Erosion Control Inspection Residential Failed 9/19/2019 09/19/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/02/2019
-REINSTALL EROSION CONTROL ALONG THE STREET -PROVIDE MIN 3/4" GRAVEL FILTER AT LOT ENTRANCE NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 9/19/2019 9/19/2019 at 9:25 AM 09/19/2019
Misc
Corrective Action Required
08/01/2019
**SEE EROSION CONTROL DEFICIENCIES. **REINSTALL EROSION CONTROL AT REAR CORNER **FOOTING NOT INSPECTED & APPROVED BY CITY. SUBMIT APPROVAL LETTER FROM THE ENGINEER OF RECORD FRAMING: -Nail rear wall siding to sill plate per code -Fire stop all floor&ceiling penetrations -Nail rafters to ceiling joists per code -Install hanger for triple ceiling beam above slide door -Install collar ties near ridge -Notched double joist at stair return air. Have engineer address this -Fb basement wall at ten ft or less interval; Fb wall from ceiling furdown space -Toe nail joists to NE basement wall top plates with three 8d nails ELECTRICAL: -Provide floodlight at rear -Install receptacle at each garage vehicle bay fed from the 20 amp dedicated circuit -Install insulating bushing at SE entry to meter enclosure -The service SE connections at main breaker not protected MECHANICAL: -Dryer duct cannot be deformed. Full 4” diameter is required per IRC 2018 -Provide combustion air openings per code for water heater -Pan off return air space from ceiling furdown space between basement bedrooms PLUMBING: -Protect water lines at master shower -Protect plumbing above wet bar; in basement bedroom closet and bathroom **OK TO INSULATE
Electrical Service Inspection Passed 9/19/2019 9/19/2019 09/19/2019
Gas Service Inspection - Residential Passed 9/19/2019 9/19/2019 09/19/2019
Driveway Inspection Partial 9/24/2019 09/24/2019
Misc
Informational
09/24/2019
Driveway forms and materials passed pre-inspection.
Driveway Inspection Passed 09/25/2019
Misc
Informational
09/24/2019
Driveway forms and materials passed pre-inspection.
Misc
Informational
09/25/2019
Driveway passed final inspection.
Erosion Control Inspection Residential Failed 10/4/2019 10/04/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/19/2019
-REINSTALL EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 10/4/2019 10/4/2019 at 9:55 AM 10/04/2019
Misc
Corrective Action Required
09/19/2019
**SEE EROSION CONTROL DEFICIENCIES. **FOOTING NOT INSPECTED & APPROVED BY CITY. SUBMIT APPROVAL LETTER FROM THE ENGINEER OF RECORD FRAMING: -Install hanger for triple ceiling beam above slide door **Not a proper hanger -Notched double joist at stair return air. Have engineer address this **The floor is not a proper place to carry load, because there is no grade beam. Get the engineer to OK this or replace the beam -Toe nail joists to NE basement wall top plates with three 8d nails **Get a palm nailer and toe-nail on each side of joist down to the plate with 3-8d nails. Doin't use bigger nail, 'cause the joist will split MECHANICAL: -Dryer duct cannot be deformed. Full 4” diameter is required per IRC 2018 **OK TO INSULATE
All Rough Inspection - Residential Passed 10/10/2019 10/10/2019 at 9:40 AM 10/10/2019
Misc
Resolved
10/10/2019
**SEE EROSION CONTROL DEFICIENCIES. FRAMING: -Install hanger for triple ceiling beam above slide door **Not a proper hanger -Notched double joist at stair return air. Have engineer address this **The floor is not a proper place to carry load, because there is no grade beam. Get the engineer to OK this or replace the beam -Toe nail joists to NE basement wall top plates with three 8d nails **Get a palm nailer and toe-nail on each side of joist down to the plate with 3-8d nails. Doin't use bigger nail, 'cause the joist will split MECHANICAL: -Dryer duct cannot be deformed. Full 4” diameter is required per IRC 2018 **OK TO INSULATE
Sidewalk Inspection Partial 12/9/2019 12/9/2019 12/18/2019
Corrective Action Required
12/09/2019
Not ready.
Misc
Informational
12/18/2019
Contractor - forms and materials passed pre- inspection.
Erosion Control Inspection Residential Passed 12/26/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/26/2019
-REINSTALL EROSION CONTROL ALONG THE STREET NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 12/26/2019 12/26/2019 at 9:55 AM 12/26/2019
Misc
Corrective Action Required
12/26/2019
-Lawn irrigation permit required -Sidewalk not approved on record -Address -As-graded plot plan is required -Lower sewer manhole to final grade -Roof drainage and downspout extensions -Sewer tracer port with wire shall be at grade level -Seal wall penetrations, seal above meter -Complete outdoor lighting -Lag deck ledger board through the spacers -Window located adjacent to stair and less than 36” above stair shall be tempered safety glass window -Install indoor lighting -Install secondary security lock for slide door -Complete kitchen hood installation -All 15-20 amp outlets located in laundry shall be gfci-protected; Provide gfci protection for dish washer -Install breaker lock for oven, cooktop, and hood -Install security strike plate at exterior door -Provide afci for kitchen hood
Occupancy Inspection - Codes Residential Failed 12/26/2019 12/26/2019
Misc
Corrective Action Required
12/26/2019
-Lawn irrigation permit required -Sidewalk not approved on record -Address -As-graded plot plan is required -Lower sewer manhole to final grade -Roof drainage and downspout extensions -Sewer tracer port with wire shall be at grade level -Seal wall penetrations, seal above meter -Complete outdoor lighting -Lag deck ledger board through the spacers -Window located adjacent to stair and less than 36” above stair shall be tempered safety glass window -Install indoor lighting -Install secondary security lock for slide door -Complete kitchen hood installation -All 15-20 amp outlets located in laundry shall be gfci-protected; Provide gfci protection for dish washer -Install breaker lock for oven, cooktop, and hood -Install security strike plate at exterior door -Provide afci for kitchen hood -ADDENUM: install box extension for the floor receptacle at rail
Sidewalk Inspection Passed 12/20/2019 12/20/2019 12/26/2019
Misc
Informational
12/26/2019
Sidewalk - passed final inspection.
Occupancy Inspection - Codes Residential Temporary C of O 12/30/2019 12/30/2019 at 11:05 AM 12/30/2019
Misc
Corrective Action Required
12/26/2019
-As-graded plot plan is required -Lower sewer manhole to final grade -Lag deck ledger board through the spacers -Window located adjacent to stair and less than 36” above stair shall be tempered safety glass window -Provide afci breaker for kitchen hood (NEC210.12)
Plot Plan Inspection Passed 4/17/2020 at 9:45 AM 04/17/2020
Occupancy Inspection - Codes Residential Temporary C of O 4/20/2020 4/20/2020 at 8:40 AM 04/20/2020
Misc
Corrective Action Required
12/30/2019
-Lag deck ledger board through the spacers; also one of the joist and hanger got pulled out of the ledger board; the stair landing posts being supported by concrete blocks, instead of piers
Occupancy Inspection - Codes Residential Full C of O 5/12/2020 5/11/2020 05/11/2020
Misc
Resolved
05/11/2020
-Lag deck ledger board through the spacers; also one of the joist and hanger got pulled out of the ledger board; the stair landing posts being supported by concrete blocks, instead of piers
Documents & Images
Date Uploaded File Type Document Name
06/06/2019 Letter Codes Residential Plan Review
06/11/2019 Receipt Receipt for transaction: 2019-003566
06/11/2019 Letter Codes Building Permit
06/12/2019 Plot Plan DOC061219-06122019082555
06/24/2019 Engineer Report/Study Garys Fndn 1112 NE Goshen Ct Lee's Summit Mo Footing Forming and Reinforcement 6-20-19
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
07/02/2019 Letter INSPECTION SUMMARY
07/02/2019 Letter INSPECTION SUMMARY
07/16/2019 Engineer Report/Study 1112 NE Goshen Ct_Lot 87 Monticello Final_2019.07.12_DPier_LSMO_Pat Cochran Concrete
08/01/2019 Letter INSPECTION SUMMARY
08/01/2019 Letter INSPECTION SUMMARY
09/19/2019 Letter INSPECTION SUMMARY
09/19/2019 Letter INSPECTION SUMMARY
09/19/2019 Letter INSPECTION SUMMARY
09/19/2019 Letter INSPECTION SUMMARY
09/24/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/10/2019 Letter INSPECTION SUMMARY
12/09/2019 Letter INSPECTION SUMMARY
12/18/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/26/2019 Letter INSPECTION SUMMARY
12/30/2019 Letter Codes Temporary Certificate of Occupancy
04/17/2020 Plot Plan M-87-AS-GRADED
04/17/2020 M-87-AS-GRADED
04/17/2020 Letter INSPECTION SUMMARY
04/20/2020 Letter Codes Temporary Certificate of Occupancy
05/11/2020 Letter Codes Final Certificate of Occupancy
05/11/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home