Permit Application Status

PRRES20191385


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191385
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
05/30/2019
06/10/2019
07/06/2022
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
JENNIFER@IQHOMEBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
FIVE STAR PLUMBING INC, Address:P O BOX 452, Phone:(816) 228-8821  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/03/2019 06/05/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
06/03/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *As-graded plot plan
Residential Plan Review Approved 06/03/2019 05/31/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $984.67 $984.67 Paid 06/10/2019
8331507-Sewer Connection Fee $450.00 $450.00 Paid 06/10/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 06/10/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 06/10/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/10/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/10/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/24/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/24/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/24/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/20/2019 (3:00) 6/20/2019 06/20/2019
Erosion Control Inspection Residential Failed 10/29/2019 06/20/2019
Underslab Plumbing Inspection - Residential Not Ready 7/15/2019 7/15/2019 07/15/2019
Misc
Corrective Action Required
07/15/2019
no address on 3 foundations proivde erosion control at rear of lots.
Underslab Plumbing Inspection - Residential Failed 7/18/2019 7/18/2019 07/18/2019
Misc
Corrective Action Required
07/15/2019
Piping covered up with gravel, call back in when not covered up
Sewer Service Inspection - R Passed 7/19/2019 (1:00) 7/19/2019 07/19/2019
Water Service Inspection - R Passed 7/25/2019 (9:00) 7/25/2019 07/25/2019
Erosion Control Inspection Residential Failed 7/31/2019 07/31/2019
Underslab Plumbing Inspection - Residential Passed 7/31/2019 7/31/2019 07/31/2019
Misc
Resolved
07/31/2019
Piping covered up with gravel, call back in when not covered up
Gas Piping Inspection - Residential Not Ready 10/29/2019 10/29/2019 10/29/2019
Misc
Corrective Action Required
10/29/2019
Denied for lack of erosion control.
Erosion Control Inspection Residential Failed 10/29/2019 10/29/2019
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/29/2019
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Piping Inspection - Residential Failed 10/30/2019 10/30/2019 10/30/2019
Misc
Corrective Action Required
10/29/2019
Denied for lack of erosion control.
Gas Service Inspection - Residential Passed 10/31/2019 10/31/2019 10/30/2019
Gas Piping Inspection - Residential Passed 10/30/2019 10/30/2019
Misc
Resolved
10/30/2019
Denied for lack of erosion control.
All Rough Inspection - Residential Failed 11/19/2019 11/19/2019 11/19/2019
Misc
Corrective Action Required
11/19/2019
- loose hold down nuts in garage throughout - support 3” piping in ceiling joist cavity, NE side of house first floor - joists hanger missing nails, SW side of house on first floor. To the right of fire place - solid fire block at top plate bump out for drain pipe and electrical on the SW side of garage, insulation not accepted - support hip ceiling rafter above master bedroom - fire block penetration through top plate, right of master bath sink - protect clothes washer water lines at bottom plate - clothes dryer exhaust vent cannot be contorted, must be in original shape - joist hanger missing nails, outside of master bedroom door - support valley ceiling joists above spare bathroom/ hallway on second level - protect piping at top and bottom plate in hall way linen closet on second level - fix hole in sub floor in hallway linen closet - support plumbing above NW spare bedroom second floor - joist hanger missing nails, in hall way outside of laundry room - fire block at bottom plate electrical penetration in NE bedroom closet - support 3” drain line above kitchen area - holes cut in floor joists for electrical within 2” of bottom of joists in kitchen - properly fire block at top plate cavity in garage, nw wall in kitchen - fire block toilet flange in spare bathroom on second floor - exterior is caulked and painted, could not properly inspect nailing pattern for siding Do not insulate
Electrical Service Inspection Passed 11/19/2019 11/19/2019 11/19/2019
All Rough Inspection - Residential Failed 11/26/2019 11/26/2019 11/26/2019
Misc
Corrective Action Required
11/26/2019
No access No lockbox code No inspection performed
Erosion Control Inspection Residential Failed 11/26/2019
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/29/2019
Install erosion control at west W/NW side of lot
All Rough Inspection - Residential Failed 12/2/2019 12/2/2019 12/02/2019
Misc
Corrective Action Required
11/26/2019
clothes dryer exhaust vent cannot be contorted, must be in original shape Ok to insulate
All Rough Inspection - Residential Passed 12/6/2019 12/6/2019 12/06/2019
Misc
Resolved
12/06/2019
Piers/Caissons Inspection - Residential Passed 12/10/2019 12/10/2019 12/10/2019
Driveway Inspection Partial 1/3/2020 1/3/2020 01/03/2020
Misc
Informational
01/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 1/9/2020 1/9/2020 01/09/2020
Misc
Informational
01/09/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 1/14/2020 01/14/2020
Sidewalk Inspection Passed 2/4/2020 02/18/2020
Misc
Resolved
02/18/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 5/8/2020 5/8/2020 05/08/2020
Misc
Corrective Action Required
05/08/2020
- SUBMIT AS GRADED PLOT PLAN - - PROVIDE IRRIGATION PERMIT - - PROVIDE GUARDRAIL OR RAISE GRADE TO 30" FRONT PORCH - - PROVIDE GUARDRAIL @ WINDOW WELL PATIO PROVIDING EGGRESS WINDOW USE - - SEAL TOP OF METER CAN & A/C DISCONNECT - - PROVIDE SUMP DISCHARGE PIPE 3' FROM FOUNDATION - - GARAGE DOOR SHALL BE SELF CLOSING AND LATCHING - - PERMIT PULLED AFTER APRIL, 1 2019 SHALL MEET CODE (NEC 2017) REQUIREMENTS: -AFCI REQUIRED PER NEC 210.12 - - TAMPER RESISTANT RECEPTACLESPER 406.12 - - DISH WASHER & LAUNDRY OUTLETS GFCI PROTECTION PER 210.8 (A) & (D)
Deck Final Inspection - Residential Passed 5/8/2020 05/08/2020
Occupancy Inspection - Codes Residential Temporary C of O 5/13/2020 5/13/2020 05/13/2020
Misc
Corrective Action Required
05/08/2020
- PROVIDE IRRIGATION PERMIT -
Plot Plan Inspection Passed 6/5/2020 06/05/2020
Misc
Informational
06/05/2020
- PROVIDE IRRIGATION PERMIT & BACKFLOW CERTIFICATION FOR C OF O -
Occupancy Inspection - Codes Residential Failed 2/8/2022 02/08/2022
Misc
Corrective Action Required
05/13/2020
- PROVIDE IRRIGATION PERMIT - Spoke with Jennifer 2/4/22 and was told this would be handled Monday 2/7/22. As of today 2/8/22 there is still no irrigation permit on this address. I have tried calling the office and can not reach anyone. Please resolve this issue so we can issue a full CO thank you.
Occupancy Inspection - Codes Residential Full C of O 7/6/2022 07/06/2022
Documents & Images
Date Uploaded File Type Document Name
06/03/2019 Letter Codes Residential Plan Review
06/10/2019 Receipt Receipt for transaction: 2019-003433
06/10/2019 Letter Codes Building Permit
06/12/2019 Plot Plan DOC061219-06122019083046
07/15/2019 Letter INSPECTION SUMMARY
07/18/2019 Letter INSPECTION SUMMARY
07/19/2019 Letter INSPECTION SUMMARY
07/25/2019 Letter INSPECTION SUMMARY
07/31/2019 Letter INSPECTION SUMMARY
10/29/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
11/19/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
12/02/2019 Letter INSPECTION SUMMARY
12/06/2019 Letter INSPECTION SUMMARY
12/10/2019 Letter INSPECTION SUMMARY
01/03/2020 Letter INSPECTION SUMMARY
01/09/2020 Letter INSPECTION SUMMARY
01/14/2020 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter Codes Temporary Certificate of Occupancy
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/04/2020 LOT 678 ASBUILT
06/05/2020 Letter INSPECTION SUMMARY
01/24/2022 Receipt Receipt for transaction:2022-000387
02/08/2022 Letter INSPECTION SUMMARY
06/28/2022 Letter Codes 140 Day Letter
07/06/2022 Letter Codes Final Certificate of Occupancy
07/06/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home