Permit Application Status

PRRES20190685


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20190685
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE, UNCOVERED DECK AND UNFINISHED BASEMENT
03/25/2019
03/28/2019
04/03/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
AMY@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/27/2019 03/27/2019
Steve Conrick
Residential Plan Review Approved 03/29/2019 03/27/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,459.41 $1,459.41 Paid 03/28/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/28/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 03/28/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 03/28/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 03/28/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/25/2019 (11:15) 4/25/2019 at 11:15 AM 04/25/2019
Water Service Inspection - R Passed 5/31/2019 5/31/2019 at 3:45 PM 05/31/2019
Sewer Service Inspection - R Partial 5/31/2019 5/31/2019 05/31/2019
Misc
Corrective Action Required
05/31/2019
20' of sewer from house out OK TO COVER. NOT ATTACHED TO STUB.
Sewer Service Inspection - R Passed 6/3/2019 6/3/2019 at 10:30 AM 06/03/2019
Misc
Resolved
06/03/2019
20' of sewer from house out OK TO COVER. NOT ATTACHED TO STUB.
Underslab Plumbing Inspection - Residential Passed 6/6/2019 6/6/2019 at 9:15 AM 06/06/2019
Electrical Service Inspection Passed 7/26/2019 7/26/2019 at 9:20 AM 07/26/2019
Gas Piping Inspection - Residential Failed 7/26/2019 7/26/2019 at 9:31 AM 07/26/2019
Misc
Corrective Action Required
07/26/2019
Terminate gas line to main floor and master bed fireplaces. Cannot use 100 psi gauge on gas line 30 psi max.
Gas Service Inspection - Residential Failed 7/26/2019 7/26/2019 07/26/2019
All Rough Inspection - Residential Failed 7/26/2019 7/26/2019 at 9:32 AM 07/26/2019
Misc
Corrective Action Required
07/26/2019
Support soffit in garage. 36” width max. Fire block fir out for hvac supply and plumbing in garage. Fire stop under duct southeast corner of garage. Install joist hangers at 3 small truss above 3rd car garage door. Install boot at plumbing vent above 3rd garage. Fire block dead space left of 1st floor tub. Fire block soffit space from attic space over beam on 3rd car garage side. Fire stop triangular dead space 1st floor bedroom. Install double joist hanger at angled double lvl in 1st floor bedroom. Fire block stud space from soffit space left and right of 4 windows in great room. Fire block dead space in southwest bedroom 2 Nd floor. Install 6 joist hangers in southeast bedroom 2nd fl. Fir out for tub/shower enclosure in southeast bath 2 Nd fl. Fire block triangular dead space left of master bath entry. Fire block dead space at right of master bed entry. GAS: terminate both gas lines to fireplaces. Cannot use 100 psi gauge on gas line. 30 psi max. Fire block firred wall at stairs horizontally and vertically. Install security blocking at basement entry door. Support hvac supply duct right and left of furnace. Repair all outside siding issues painted on exterior by builder.
All Rough Inspection - Residential Passed 8/6/2019 8/6/2019 at 9:30 AM 08/06/2019
Misc
Resolved
08/06/2019
Support soffit in garage. 36” width max. Fire block fir out for hvac supply and plumbing in garage. Fire stop under duct southeast corner of garage. Install joist hangers at 3 small truss above 3rd car garage door. Install boot at plumbing vent above 3rd garage. Fire block dead space left of 1st floor tub. Fire block soffit space from attic space over beam on 3rd car garage side. Fire stop triangular dead space 1st floor bedroom. Install double joist hanger at angled double lvl in 1st floor bedroom. Fire block stud space from soffit space left and right of 4 windows in great room. Fire block dead space in southwest bedroom 2 Nd floor. Install 6 joist hangers in southeast bedroom 2nd fl. Fir out for tub/shower enclosure in southeast bath 2 Nd fl. Fire block triangular dead space left of master bath entry. Fire block dead space at right of master bed entry. GAS: terminate both gas lines to fireplaces. Cannot use 100 psi gauge on gas line. 30 psi max. Fire block firred wall at stairs horizontally and vertically. Install security blocking at basement entry door. Support hvac supply duct right and left of furnace. Repair all outside siding issues painted on exterior by builder.
Gas Piping Inspection - Residential Failed 8/6/2019 8/6/2019 at 9:50 AM 08/06/2019
Misc
Corrective Action Required
07/26/2019
Terminate gas line to main floor and master bed fireplaces. Cannot use 100 psi gauge on gas line 30 psi max.
Misc
Corrective Action Required
08/06/2019
Terminate gas line to main floor and master bed fireplaces. Cannot use 100 psi gauge on gas line 30 psi max.
Gas Service Inspection - Residential Failed 8/6/2019 8/6/2019 08/06/2019
Misc
Corrective Action Required
08/06/2019
cannot use 100 psi gauge on gas line. 30 psi max. connect gas line at fireplaces.
Gas Piping Inspection - Residential Passed 8/9/2019 8/9/2019 at 1:46 PM 08/09/2019
Misc
Corrective Action Required
08/06/2019
Terminate gas line to main floor and master bed fireplaces. Cannot use 100 psi gauge on gas line 30 psi max.
Misc
Resolved
08/09/2019
Terminate gas line to main floor and master bed fireplaces. Cannot use 100 psi gauge on gas line 30 psi max.
Gas Service Inspection - Residential Passed 8/9/2019 8/9/2019 08/09/2019
Misc
Resolved
08/09/2019
cannot use 100 psi gauge on gas line. 30 psi max. connect gas line at fireplaces.
Driveway Inspection Partial 8/15/2019 8/15/2019 08/15/2019
Misc
Informational
08/15/2019
AUGUST 15, 2019 PRE POUR INSPECTION All forms meet Lees Summit and ADA spec. There is gravel installed and it is compacted. Contractor will call back for sidewalk inspection also.
Driveway Inspection Passed 08/21/2019
Misc
Informational
08/15/2019
AUGUST 15, 2019 PRE POUR INSPECTION All forms meet Lees Summit and ADA spec. There is gravel installed and it is compacted. Contractor will call back for sidewalk inspection also.
Misc
Informational
08/21/2019
AUGUST 21, 2019 POST POUR INSPECTION PASS All forms meet Lees Summit and ADA spec.
Occupancy Inspection - Codes Residential Not Ready 10/1/2019 10/1/2019 10/01/2019
Misc
Informational
10/01/2019
Too many items are incomplete
Sidewalk Inspection Partial 10/18/2019 (A.M.) 10/18/2019 10/18/2019
Misc
Corrective Action Required
10/18/2019
PRE POUR INSPECTION There appears to be sufficient compacted aggregate. The forms for the ADA ramp section of the sidewalk are out of compliance. The remainder of the sidewalk forms appear to be set in compliance. The contractor is going to make corrections to the ADA forms prior to pouring the ramp and call back for pre-inspection.
Sidewalk Inspection Partial 10/21/2019 10/22/2019 10/21/2019
Misc
Corrective Action Required
10/18/2019
PRE POUR INSPECTION There appears to be sufficient compacted aggregate. The forms for the ADA ramp section of the sidewalk are out of compliance. The remainder of the sidewalk forms appear to be set in compliance. The contractor is going to make corrections to the ADA forms prior to pouring the ramp and call back for pre-inspection.
Misc
Informational
10/21/2019
PRE POUR INSPECTION The crew made corrections to the ADA ramp section of the sidewalk. I will return for a follow up post pour inspection at a later date.
Occupancy Inspection - Codes Residential Failed 10/22/2019 10/22/2019 10/22/2019
Misc
Informational
10/01/2019
No key in lock box, no access. No inspection performed
Occupancy Inspection - Codes Residential Failed 10/24/2019 10/24/2019 10/24/2019
Misc
Corrective Action Required
10/24/2019
- No address posted - establish erosion control at front and rear of lot, clean up street - final grade, sod , splash blocks - seal outside light fixtures - drain line for dishwasher needs to be secured above - faceplate needed for outlet to the right of master bedroom fireplace - need access to underneath Jacuzzi tub in master bath - faceplate needed for laundry room switch - ledger lock screws need to be installed, back deck - railing on front porch needed on south side - sump pump discharge needs to be 36” from foundation - power chord being ran from adjacent house to basement needs to be removed - Down spout at front entrance needs to be complete
Occupancy Inspection - Codes Residential Temporary C of O 10/30/2019 10/30/2019 10/30/2019
Misc
Corrective Action Required
10/24/2019
TCO - final grade, sod , splash blocks
Sidewalk Inspection Passed 10/28/2019 12/09/2019
Misc
Corrective Action Required
10/21/2019
PRE POUR INSPECTION There appears to be sufficient compacted aggregate. The forms for the ADA ramp section of the sidewalk are out of compliance. The remainder of the sidewalk forms appear to be set in compliance. The contractor is going to make corrections to the ADA forms prior to pouring the ramp and call back for pre-inspection.
Misc
Informational
10/21/2019
PRE POUR INSPECTION The crew made corrections to the ADA ramp section of the sidewalk. I will return for a follow up post pour inspection at a later date.
Plot Plan Inspection Passed 04/03/2020
Occupancy Inspection - Codes Residential Full C of O 4/3/2020 4/3/2020 04/03/2020
Misc
Informational
10/22/2019
No key in lock box, no access. No inspection performed
Documents & Images
Date Uploaded File Type Document Name
03/28/2019 Receipt Receipt for transaction: 2019-001103
03/28/2019 Letter Codes Building Permit
03/29/2019 Plot Plan DOC032919-03292019141812
04/25/2019 Letter INSPECTION SUMMARY
05/31/2019 Letter INSPECTION SUMMARY
05/31/2019 Letter INSPECTION SUMMARY
06/03/2019 Letter INSPECTION SUMMARY
06/06/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
07/26/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/15/2019 AUGUST 15, 2019 PRE POUR DRIVEWAY
08/15/2019 Letter INSPECTION SUMMARY
08/21/2019 AUGUST 21, 2019 POST POUR Driveway
08/21/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
10/18/2019 Letter INSPECTION SUMMARY
10/21/2019 Letter INSPECTION SUMMARY
10/22/2019 Letter INSPECTION SUMMARY
10/24/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter Codes Temporary Certificate of Occupancy
12/09/2019 Letter INSPECTION SUMMARY
04/03/2020 Letter Codes Final Certificate of Occupancy
04/03/2020 Letter Field Certificate of Occupancy
Upload Documents
  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.