Permit Application Status

PRRES20182954


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20182954
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE UNFINSIHED BASEMENT COVERED DECK STOP WORK ORDER generated on 07/26/2019 12:00 AM by username 'Khanh Nguyen'. STOP WORK ORDER removed on 08/28/2019 12:00 AM by username 'Khanh Nguyen'.
09/04/2018
09/28/2018
10/07/2019
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
FIVE STAR MECHANICAL CONTRACT INC, Address:P O BOX 11964, Phone:(816) 358-4444  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DRDRICHARDS3@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/06/2018 09/17/2018
Brandon Kalwei
Plot Plan Review Approved 09/06/2018 09/06/2018
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $957.58 $957.58 Paid 09/28/2018
Right of Way Permit Fee $80.00 $80.00 Paid 09/28/2018
8331507-Sewer Connection Fee $360.00 $360.00 Paid 09/28/2018
Water Tap Fee $3,409.00 $3,409.00 Paid 09/28/2018
Water Meter Fee $408.37 $408.37 Paid 09/28/2018
Valuation Fee New Single Family $37.96 $37.96 Paid 05/22/2019
$995.54
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection - R Partial 11/14/2018 11/14/2018 11/14/2018
Sewer Service Inspection - R Failed 11/14/2018 11/14/2018 at 9:15 AM 11/14/2018
Misc
Corrective Action Required
11/14/2018
-INSTALL 2 CLEANOUTS AT SEWER BENDS ON BOTH SIDES OF THE HOUSE
Sewer Service Inspection - R Passed 11/14/2018 at 11:30 AM 11/14/2018
Misc
Resolved
11/14/2018
-INSTALL 2 CLEANOUTS AT SEWER BENDS ON BOTH SIDES OF THE HOUSE
Water Service Inspection - R Passed 11/16/2018 11/16/2018 at 2:15 PM 11/16/2018
Underslab Plumbing Inspection - Residential Failed 11/19/2018 at 10:25 AM 11/19/2018
Misc
Corrective Action Required
11/19/2018
-SLEEVE TO PROTECT WATER LINE AT FLOOR SLAB
Erosion Control Inspection Residential Failed 1/9/2019 01/09/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/09/2019
EROSION CONTROL SHALL BE INSTALLED AROUND THE LOT INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 1/9/2019 1/9/2019 at 10:35 AM 01/09/2019
Misc
Corrective Action Required
01/09/2019
GARAGE PORTAL WALL ONLY: INSTALL STRAP AT THE INNER SIDE OF THE BRACE WALL. OK TO COVER EXTERIOR
Erosion Control Inspection Residential Failed 2/6/2019 02/06/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/09/2019
-EROSION CONTROL SHALL BE INSTALLED AND RE-ESTABLISHED AROUND THE LOT -STREET SHALL BE CLEANED *INSPECTION DENIED *NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE.
Electrical Service Inspection Failed 2/6/2019 2/6/2019 02/06/2019
Misc
Corrective Action Required
02/06/2019
**INSPECTION DENIED DUE TO EROSION CONTROL DEFICIENCY
All Rough Inspection - Residential Failed 2/7/2019 2/6/2019 at 8:50 AM 02/06/2019
Misc
Corrective Action Required
01/09/2019
**INSPECTION DENIED DUE TO EROSION CONTROL DEFICIENCY
Gas Service Inspection - Residential Failed 2/6/2019 2/6/2019 02/06/2019
Misc
Corrective Action Required
02/06/2019
**INSPECTION DENIED DUE TO EROSION CONTROL DEFICIENCY
Electrical Service Inspection Passed 2/8/2019 2/8/2019 02/08/2019
Misc
Resolved
02/08/2019
Gas Service Inspection - Residential Failed 2/8/2019 2/8/2019 02/08/2019
Misc
Corrective Action Required
02/06/2019
-Complete gas piping and retest
Erosion Control Inspection Residential Failed 2/8/2019 02/08/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2019
-EROSION CONTROL SHALL BE INSTALLED AND RE-ESTABLISHED AROUND THE LOT -STREET SHALL BE CLEANED *NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE.
All Rough Inspection - Residential Failed 2/8/2019 2/8/2019 at 9:25 AM 02/08/2019
Misc
Corrective Action Required
02/06/2019
**EROSION CONTROL SHALL BE IN COMPLIANCE. NO FURTHER INSPECTION FRAMING: -Provide city-approved plan on site -Fb laundry wall from roof -Install collar ties at top roof ridge -Roof flashing for plumbing vent -Frame CS-PF walls per plan -Engineer to address 2x4 non-continuous studs at great room exterior wall -Fill in void between rear exterior door frame and stud with solid wood, from 12” above to 12” below strike plate per security code -Support triple joist beam to stair bearing wall/lvl below -Install bearing wall below master bed/great room wall -Support kitchen I beam point load all the way down to footing -Solid-block cantilevered joists in basement -Toe nail all joists to basement sill plates ELECTRICAL: -Complete electrical above stair and great room -Move smoke alarm near top of vaulted ceiling outside master bedroom PLUMBING: -Complete gas piping **DO NOT INSULATE
All Rough Inspection - Residential Failed 2/25/2019 2/25/2019 at 9:30 AM 02/25/2019
Misc
Corrective Action Required
02/08/2019
FRAMING: -Provide city-approved plan on site **You have the red-stamped copy of the plan? -Fb laundry wall from roof **foam gap -Frame CS-PF walls per plan **see the plan detail please -Engineer to address 2x4 non-continuous studs at great room exterior wall -Solid-block cantilevered joists in basement **below fireplace -Toe nail all joists to basement sill plates **not all joists are toe-naled to sill plates **DO NOT INSULATE BASEMENT SILL PLATES
Gas Service Inspection - Residential Failed 2/25/2019 2/25/2019 02/25/2019
Misc
Corrective Action Required
02/08/2019
-Install a working pressure gauge. The needle does not move when pressure is released
Gas Service Inspection - Residential Passed 2/27/2019 at 1:05 PM 02/27/2019
Misc
Resolved
02/27/2019
-Install a working pressure gauge. The needle does not move when pressure is released
All Rough Inspection - Residential Failed 3/27/2019 3/27/2019 at 3:10 PM 03/27/2019
Misc
Corrective Action Required
02/25/2019
FRAMING: -Provide city-approved plan on site **You have the red-stamped copy of the plan? **The city does not have a mean to copy the plan and give it to you. You should contact the permit technician about the missing plan -Frame CS-PF walls per plan **see the plan detail please **the CSPF walls are not framed per plan. You must get your engineer involved -Toe nail all joists to basement sill plates **not all joists are toe-naled to sill plates **look at the front foundation walls **DO NOT INSULATE BASEMENT SILL PLATES
All Rough Inspection - Residential Partial 4/2/2019 4/2/2019 at 2:14 PM 04/02/2019
Misc
Corrective Action Required
03/27/2019
SUBMIT THE ENGINEER REPORT THAT WAS ON SITE TO THE OFFICE SO IT CAN BE FILED WITH THE PERMIIT.
All Rough Inspection - Residential Passed 4/3/2019 4/3/2019 at 9:00 AM 04/03/2019
Misc
Resolved
04/03/2019
SUBMIT THE ENGINEER REPORT THAT WAS ON SITE TO THE OFFICE SO IT CAN BE FILED WITH THE PERMIIT.
Piers/Caissons Inspection - Residential Failed 4/10/2019 4/10/2019 at 8:20 AM 04/10/2019
Misc
Corrective Action Required
04/10/2019
-REMOVE ALL LOOSE DIRT AND GRAVEL FROM PIER HOLES
Piers/Caissons Inspection - Residential Passed 4/10/2019 (1:00) 4/10/2019 at 1:45 PM 04/10/2019
Misc
Resolved
04/10/2019
-REMOVE ALL LOOSE DIRT AND GRAVEL FROM PIER HOLES
Driveway Inspection Partial 4/15/2019 (P.M.) 4/15/2019 04/16/2019
Informational
04/16/2019
Forms and materials passed pre-inspection.
Driveway Inspection Passed 4/23/2019 04/25/2019
Misc
Informational
04/25/2019
Final Inspection Passed.
Erosion Control Inspection Residential Failed - Stop Work 7/26/2019 at 8:50 AM 07/26/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/08/2019
-EROSION CONTROL SHALL BE INSTALLED AND RE-ESTABLISHED AROUND THE LOT -STREET SHALL BE CLEANED IMMEDIATELY **7/24-LEFT A MESSAGE ABOUT THE MUD DEPOSIT ONTO THE STREET FROM LACK OF EROSION CONTROL. NOTHING WAS DONE ON 7/26. **STOP-WORK ORDER ISSUED **NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 08/28/2019
Misc
Resolved
02/08/2019
-SLEEVE TO PROTECT WATER LINE AT FLOOR SLAB
Erosion Control Inspection Residential Passed 08/28/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/28/2019
-EROSION CONTROL SHALL BE INSTALLED AND RE-ESTABLISHED AROUND THE LOT -STREET SHALL BE CLEANED IMMEDIATELY **7/24-LEFT A MESSAGE ABOUT THE MUD DEPOSIT ONTO THE STREET FROM LACK OF EROSION CONTROL. NOTHING WAS DONE ON 7/26. **STOP-WORK ORDER ISSUED **NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IS IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 8/28/2019 at 9:00 AM 08/28/2019
Misc
Corrective Action Required
08/28/2019
-Footing not inspected and approved by city. Submit engineer approval letter -Final grade, sod, splashblocks -Install sewer tracer box and wire -Expose sewer manhole at front corner of lot. Bring sewer MH to final grade level -Seal exterior wall penetrations, seal above meter, AC disconnect, etc -Install tamper proof caps at AC valves -Install handrail per code at front stair -Garage door not self closing -Fb basement from garage -At any point along the kitchen countertop wall , there must be a receptacle within two ft -Install a security strike plate fastened with 3” screws into studs -Rear exterior stair riser height not per code. Either provide 3 ft landing or lower the top tread so that the maximum riser height difference is no more than 3/8”. FYI: Handrail is required for stair with four or more risers -Master bedroom Afci not tripping -Install single plug receptacle for sump pump and install cover plate -Remove all foundation wall ties -Complete wiring to water heater -Provide provision to clean out furnace condensate drain
Occupancy Inspection - Codes Residential Failed 9/4/2019 9/4/2019 at 9:35 AM 09/04/2019
Misc
Corrective Action Required
08/28/2019
-Final grade, sod, splashblocks -Expose sewer manhole at front corner of lot. -Install handrail per code at front stair -Fb basement from garage -At any point along the kitchen countertop wall , there must be a receptacle within two ft
Occupancy Inspection - Codes Residential Temporary C of O 9/5/2019 9/5/2019 at 9:15 AM 09/05/2019
Misc
Corrective Action Required
09/04/2019
-Raise the sewer manhole at front corner of lot to final grade.
Occupancy Inspection - Codes Residential Full C of O 10/7/2019 at 9:35 AM 10/07/2019
Misc
Resolved
10/07/2019
-Raise the sewer manhole at front corner of lot to final grade.
Documents & Images
Date Uploaded File Type Document Name
09/05/2018 Letter Codes Residential Plan Review
09/28/2018 Receipt Receipt for transaction: 2018-006614
09/28/2018 Letter Codes Building Permit
10/01/2018 Plot Plan DOC100118-10012018095806
11/16/2018 Letter INSPECTION SUMMARY
11/20/2018 Letter INSPECTION SUMMARY
01/09/2019 Letter INSPECTION SUMMARY
02/06/2019 Letter INSPECTION SUMMARY
02/06/2019 INSPECTION SUMMARY_20190206085713
02/06/2019 Letter INSPECTION SUMMARY
02/06/2019 Letter INSPECTION SUMMARY
02/06/2019 Letter INSPECTION SUMMARY
02/25/2019 Letter INSPECTION SUMMARY
02/25/2019 Letter INSPECTION SUMMARY
02/27/2019 Letter INSPECTION SUMMARY
03/27/2019 Letter INSPECTION SUMMARY
04/02/2019 Letter INSPECTION SUMMARY
04/02/2019 Engineer Report/Study DRHI 4716 NE Gateway Dr LSMO Non Continuous 2x4 Studs GR & Braced Wall Panels 3-2-19
04/03/2019 Letter INSPECTION SUMMARY
04/10/2019 Letter INSPECTION SUMMARY
04/10/2019 Letter INSPECTION SUMMARY
04/16/2019 Letter DE-Daily Inspection Summary
04/25/2019 Letter INSPECTION SUMMARY
04/25/2019 Letter DE-Daily Inspection Summary
04/25/2019 Letter INSPECTION SUMMARY
05/22/2019 Receipt Receipt for transaction: 2019-002693
05/22/2019 Letter Codes Building Permit
07/26/2019 Letter Stop Work Order
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter INSPECTION SUMMARY
09/03/2019 Engineer Report/Study Garys Fndn 4716 NE Gateway Dr Lee's Summit Mo Footings 10-17-18
09/04/2019 Engineer Report/Study Garys Fndn 4716 NE Gateway Dr Lee's Summit Mo Footings 10-17-18 (002)
09/04/2019 Letter INSPECTION SUMMARY
09/05/2019 Letter Codes Temporary Certificate of Occupancy
10/07/2019 Letter Codes Final Certificate of Occupancy
10/07/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home