Permit Application Status

PRRES20181397


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181397
Building Permit - Residential
Certificate of Occupancy
MONTICELLO HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
05/08/2018
05/10/2018
09/16/2019
Locations
Contacts
MONTICELLO HOMES INC, Address:623 NE LONE HILL DR  
MONTICELLO HOMES INC, Address:PO BOX 7005, Phone:(816) 478-4740  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 05/10/2018 05/09/2018
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
05/08/2018

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) inside and outside bedrooms 3 and 4
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
05/08/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) does not specify uninterrupted height
Plot Plan Review Approved 05/10/2018 05/08/2018
Troy Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,009.61 $1,009.61 Paid 05/10/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 05/10/2018
8331507-Sewer Connection Fee $420.00 $420.00 Paid 05/10/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 05/10/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 05/10/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/16/2018 5/16/2018 at 11:15 AM 05/16/2018
Sewer Service Inspection - R Passed 6/5/2018 6/5/2018 at 11:05 AM 06/05/2018
Water Service Inspection - R Partial 6/5/2018 6/5/2018 06/05/2018
Underslab Plumbing Inspection - Residential Passed 6/7/2018 6/6/2018 at 3:35 PM 06/06/2018
Water Service Inspection - R Passed 6/7/2018 6/7/2018 at 9:45 AM 06/07/2018
Piers/Caissons Inspection - Residential Not Ready 7/10/2018 (11:00) 7/10/2018 at 11:30 AM 07/10/2018
Misc
Corrective Action Required
07/10/2018
NO PIER HOLES DUG AT TIME OF INSPECTION
Piers/Caissons Inspection - Residential Passed 7/11/2018 (3:00) 7/11/2018 at 11:00 AM 07/11/2018
Misc
Resolved
07/11/2018
NO PIER HOLES DUG AT TIME OF INSPECTION
Electrical Service Inspection Passed 9/4/2018 9/4/2018 09/04/2018
Gas Service Inspection - Residential Passed 9/4/2018 9/4/2018 09/04/2018
All Rough Inspection - Residential Failed 9/4/2018 9/4/2018 at 8:00 AM 09/04/2018
Misc
Corrective Action Required
09/04/2018
**RESTORE EROSION CONTROL FRAMING: -Nail siding to sill plate on east side @6” oc -Block openings between rafters along exterior wall where the soffit is less than 10 ft from the adjacent house soffit; or provide 1 hr fire protection and no soffit openings -Over cut stud at west side of garage -2” washers required at garage portal wall -Collar ties per code -Fb all floor penetrations -Directly support roof strut at garage wall; above door opening at top stair landing -Complete framing at fireplace -Nail corner studs per code -Nail master bedroom ceiling beam hangers -Security blocking for deck and basement door -Min 5 stud support for I beam at kitchen wall Fireblocking: Fb stair wall from ceiling space; Fb wet bar wall per code -Toe nail all joists to wall top plates and sill plates with 3-8d nails -Over cut stud at west basement wall -Solidblock joist ends above basement I beam -Anchor basement wall sill plate within 12” of break. -Support joist located above opening to space under stoop PLUMBING: -Protect plumbing at garage/pantry wall -Vent front bathroom tub trap ELECTRICAL: -Complete wiring at fireplace -Install a receptacle at east foyer wall -Protect wiring at front bedroom bottom wall plate -Install receptacle at rear basement wall to meet min spacing requirement -Parallel electrical inside return air space above wet bar **OK TO INSULATE
All Rough Inspection - Residential Failed 9/10/2018 9/10/2018 at 9:20 AM 09/10/2018
Misc
Corrective Action Required
09/04/2018
FRAMING: -Complete framing at fireplace **Nail the fireplace to the framing -Security blocking for deck and basement door -Min 5 stud support for I beam at kitchen wall **Close gap between studs and nail together with 16d @24" (or equivalent nailing) -Solidblock joist ends above basement I beam -Support joist located above opening to space under stoop **OK TO INSULATE
All Rough Inspection - Residential Failed 9/14/2018 9/14/2018 at 8:55 AM 09/14/2018
Misc
Corrective Action Required
09/10/2018
-Solidblock joist ends above basement I beam **OK TO INSULATE
All Rough Inspection - Residential Passed 9/17/2018 at 9:05 AM 09/17/2018
Misc
Resolved
09/17/2018
-Solidblock joist ends above basement I beam **OK TO INSULATE
Driveway Inspection Partial 12/11/2018 12/17/2018 12/17/2018
Misc
Informational
12/17/2018
Froms and materials met required specfications for driveway.
Misc
Informational
12/18/2018
Contractor poured concrete and met specifications.
Sidewalk Inspection Partial 12/11/2018 12/11/2018 12/17/2018
Misc
Informational
12/17/2018
Repair to existing sidewalk met specification.
Occupancy Inspection - Codes Residential Failed 12/18/2018 12/18/2018 at 9:10 AM 12/18/2018
Misc
Corrective Action Required
12/18/2018
-Driveway ad sidewalk not approved on record -Final grade, sod, splashblocks -Lag screw deck ledger board per code -Install two 1/2” through bolts at each deck beam connection to post -Deck cedar posts cannot be buried into soil -Install mud closet light -Complete kitchen countertop electrical -Install spark rings for wall receptacle boxes recessed more than 1/4” behind wall at kitchen countertop, fireplace, and basement wet bar -Breaker lock for oven
Driveway Inspection Passed 12/18/2018 12/18/2018
Misc
Informational
12/17/2018
Froms and materials met required specfications for driveway.
Corrective Action Required
12/18/2018
Concrete was poured and Driveway mets specification.
Driveway Inspection Passed 12/18/2018 12/18/2018
Informational
12/18/2018
passed!
Occupancy Inspection - Codes Residential Temporary C of O 12/19/2018 12/19/2018 at 8:00 AM 12/19/2018
Misc
Corrective Action Required
12/18/2018
-Sidewalk not approved on record -Final grade, sod, splashblocks -Lag screw deck ledger board per code -Install two 1/2” through bolts at each deck beam connection to post -Deck cedar posts cannot be buried into soil
Occupancy Inspection - Codes Residential Temporary C of O 4/2/2019 04/02/2019
Misc
Corrective Action Required
12/19/2018
-Sidewalk not approved on record -Final grade, sod, splashblocks -Lag screw deck ledger board per code -Install two 1/2” through bolts at each deck beam connection to post -Deck cedar posts cannot be buried into soil
Sidewalk Inspection Passed 05/16/2019
Misc
Informational
05/16/2019
Sidewalk passed final inspection. Pass due close out.
Occupancy Inspection - Codes Residential Failed 5/16/2019 at 8:50 AM 05/16/2019
Misc
Corrective Action Required
04/02/2019
-Final grade, sod, splashblocks -Install two 1/2” through bolts at each deck beam connection to post
Occupancy Inspection - Codes Residential Full C of O 9/16/2019 9/16/2019 at 8:20 AM 09/16/2019
Misc
Resolved
09/16/2019
-Final grade, sod, splashblocks -Install two 1/2” through bolts at each deck beam connection to post
Documents & Images
Date Uploaded File Type Document Name
05/08/2018 Letter Codes Residential Plan Review
05/10/2018 Receipt Receipt for transaction: 2018-002315
05/10/2018 Letter Codes Building Permit
05/10/2018 Plot Plan DOC051018-008
05/16/2018 Letter Inspection Summary
06/05/2018 Letter Inspection Summary
06/06/2018 Letter Inspection Summary
06/07/2018 Letter Inspection Summary
07/10/2018 Letter Inspection Summary
07/11/2018 Letter Inspection Summary
09/04/2018 Letter Inspection Summary
09/10/2018 Letter Inspection Summary
09/14/2018 Letter Inspection Summary
09/17/2018 Letter Inspection Summary
12/18/2018 Letter INSPECTION SUMMARY
12/18/2018 Letter INSPECTION SUMMARY
04/02/2019 Letter Codes Temporary Certificate of Occupancy
05/16/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
05/16/2019 Letter INSPECTION SUMMARY
09/16/2019 Letter Codes Final Certificate of Occupancy
09/16/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home