Summary
PRRES20180146
Building Permit - Residential
Certificate of Occupancy
D&D BUILDING INC(DBA DREAMS & DESIGN INC
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT COVERED DECK
01/19/2018
02/01/2018
11/06/2018
Locations
Contacts
D&D BUILDING INC(DBA DREAMS & DESIGN INC, Address:5282 NE ASHGROVE CT  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
MORGAN MILLER PLUMBING, Address:13911 NORBY RD, Phone:(816) 765-4843  
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 01/23/2018 01/30/2018
Brandon Kalwei
Plot Plan Review Approved 01/23/2018 01/19/2018
Troy Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,050.95 $1,050.95 Paid 02/01/2018
Right of Way Permit Fee $75.00 $75.00 Paid 02/01/2018
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/01/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 02/01/2018
Water Meter Fee $431.83 $431.83 Paid 02/01/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/2/2018 (3:30) 2/2/2018 at 3:00 PM 02/02/2018
Erosion Control Inspection Residential Failed 2/5/2018 02/05/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/05/2018
EROSION CONTROL REQUIRED, EVEN BEFORE THE FOOTING INSPECTION. ABSOLUTELY NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Passed 2/23/2018 2/23/2018 at 1:00 PM 02/23/2018
Water Service Inspection - R Passed 2/26/2018 2/26/2018 at 10:05 AM 02/26/2018
Underslab Plumbing Inspection - Residential Passed 2/27/2018 2/27/2018 at 9:40 AM 02/27/2018
Gas Service Inspection - Residential Passed 4/24/2018 4/24/2018 at 10:25 AM 04/24/2018
Electrical Service Inspection Failed 5/2/2018 5/2/2018 05/02/2018
Misc
Corrective Action Required
05/02/2018
-INSTALL A LISTED REBAR GROUNDING CLAMP. NO DISIMILAR METAL-METAL CONTACT
All Rough Inspection - Residential Failed 5/2/2018 5/2/2018 at 9:50 AM 05/02/2018
Misc
Corrective Action Required
05/02/2018
FRAMING: -Fb foyer/garage wall from roof; Fb all floor penetrations; Fb basement wall from soffits; Fb wall vertically at max ten ft interval -Anchor garage and basement sill plate per code. Some missing washers&nuts -Two stud support under double joist below master bed -Solidblock cantilevered joists below master bed -Security block for all exterior doors -Nail corner studs per code -Nail CSPF wall sheathing to header per plan; block and nail seams -Move roof supporting struts above master bath to bearing wall -Provide full support for roof strut at foyer closet/bath wall -Add another strut support for ridge above front bed MECHANICAL: -Lower duct to basement bath ceiling level -Secure basement fireplace to framing PLUMBING: -Secure gas csst line at fireplace -Nail all stud shoes at kitchen exterior wall and laundry wall -Strap wall top plates bored more than 50% at front bath ELECTRICAL: -Install wall receptacle spacing per code at front basement bed -Protect wiring at exterior kitchen wall above cooktop **DO NOT INSULATE
All Rough Inspection - Residential Failed 5/4/2018 5/4/2018 at 2:30 PM 05/04/2018
Misc
Corrective Action Required
05/02/2018
FRAMING: -Fb basement wall from soffit MECHANICAL: -Lower duct to basement bath ceiling level **OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 5/11/2018 5/11/2018 05/11/2018
All Rough Inspection - Residential Passed 5/11/2018 at 9:31 AM 05/11/2018
Misc
Resolved
05/11/2018
FRAMING: -Fb basement wall from soffit MECHANICAL: -Lower duct to basement bath ceiling level **OK TO INSULATE
Electrical Service Inspection Passed 5/11/2018 at 9:40 AM 05/11/2018
Misc
Resolved
05/11/2018
-INSTALL A LISTED REBAR GROUNDING CLAMP. NO DISIMILAR METAL-METAL CONTACT
Driveway Inspection Passed 7/9/2018 7/12/2018 at 8:00 AM 07/12/2018
Informational
07/12/2018
When I went to inspect this the curb was chipped, I asked them to tear it out and saw cut to the joint. They have made the correction. The contractor poured the driveway approach. There is not sidewalk. Steve Robbins 07/12/2018 8:47 AM
Occupancy Inspection - Codes Residential Failed 9/7/2018 9/7/2018 at 2:10 PM 09/07/2018
Misc
Corrective Action Required
09/07/2018
-Exterior not ready. paint gas piping, bond gas piping, seal exterior penetrations, install receptacle, etc -Final grade, sod, roof drainage and splashblocks -The sewer tracer box and wire shall be accessible at grade level -Luminare in master closet not compliant with NEC 410 -Receptacle left side of master bath sink not working -Install light above deck outside dining&master bed -Garage receptacles not gfci -Install box extension for all receptacle boxes recessed more than 1/4" behind non-combustible wall finish -Tv outlet box above fireplace recessed behind combustible wall. Instal spark ring -Support receptacle at wet bar under cabinet -Complete electrical above wet bar -Complete wiring to water heater and install breaker -Install breaker lock for oven -Ac breaker tie broken -Receptacles around furnace not gfci -Install battery backup for sump pump
Occupancy Inspection - Codes Residential Failed 9/12/2018 9/12/2018 at 8:35 AM 09/12/2018
Misc
Corrective Action Required
09/07/2018
-Exterior not ready. paint gas piping, bond gas piping, seal exterior penetrations, install receptacle, etc -Final grade, sod, roof drainage and splashblocks -The sewer tracer box and wire shall be accessible at grade level -Luminare in master closet not compliant with NEC 410 -Receptacle left side of master bath sink not working -Install light above deck outside dining&master bed -Garage receptacles not gfci -Install box extension for all receptacle boxes recessed more than 1/4" behind non-combustible wall finish -Tv outlet box above fireplace recessed behind combustible wall. Instal spark ring -Support receptacle at wet bar under cabinet -Complete electrical above wet bar -Complete wiring to water heater and install breaker -Install breaker lock for oven -Ac breaker tie broken -Receptacles around furnace not gfci -Install battery backup for sump pump
Occupancy Inspection - Codes Residential Temporary C of O 10/31/2018 at 1:20 PM 10/31/2018
Misc
Corrective Action Required
09/12/2018
-Secure AC whip -The sewer tracer box and wire shall be accessible at grade level -Receptacle left side of master bath sink not working **now receptacles on both sides are not gfci-protected
Occupancy Inspection - Codes Residential Full C of O 11/6/2018 11/6/2018 at 7:30 AM 11/06/2018
Misc
Resolved
11/06/2018
-Secure AC whip -The sewer tracer box and wire shall be accessible at grade level -Receptacle left side of master bath sink not working **now receptacles on both sides are not gfci-protected
Documents & Images
Date Uploaded File Type Document Name
01/19/2018 Letter Codes Residential Plan Review
02/01/2018 Receipt Receipt for transaction: 2018-000388
02/01/2018 Letter Codes Building Permit
02/01/2018 Plot Plan DOC020118-008
02/02/2018 Letter Inspection Summary
02/05/2018 Letter Inspection Summary
02/23/2018 Letter Inspection Summary
02/26/2018 Letter Inspection Summary
02/27/2018 Letter Inspection Summary
04/24/2018 Letter Inspection Summary
05/02/2018 Letter Inspection Summary
05/04/2018 Letter Inspection Summary
05/11/2018 Letter Inspection Summary
07/12/2018 Letter DE-Daily Inspection Summary
09/07/2018 Letter Inspection Summary
09/12/2018 Letter Inspection Summary
10/31/2018 Letter Codes Temporary Certificate of Occupancy
11/06/2018 Letter Field Certificate of Occupancy
12/06/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents