PRRES20172030


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20172030
Building Permit - Residential
Certificate of Occupancy
CHAPEL RIDGE RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK FINISHED BASEMENT
06/19/2017
06/29/2017
12/19/2017
01/04/2018
Locations
Contacts
CHAPEL RIDGE RESIDENTIAL LLC, Address:3170 NE CARNEGIE DR #400  
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/27/2017 06/23/2017
Jonathon Hilton
Building elevations
Corrective Action Required
06/23/2017

Existing and finished elevations at building footprint corners must be provided on the plot plan. *Can you please double check the S and the W corners of the house and make sure they are correct with the contours called out on the plot plan.
Garage elevation
Corrective Action Required
06/23/2017

The garage floor elevation must be provided on the plot plan. *Can you please double check the garage floor elevation.
Misc
Corrective Action Required
06/23/2017

*Can you provide the walkout location and LAG.
Residential Plan Review Approved 06/27/2017 06/23/2017
Jonathon Hilton
Plot Plan Review Approved 06/21/2017 06/23/2017
Nick Lightner
Building elevations
Resolved
06/23/2017

Existing and finished elevations at building footprint corners must be provided on the plot plan. *Can you please double check the S and the W corners of the house and make sure they are correct with the contours called out on the plot plan.
Garage elevation
Resolved
06/23/2017

The garage floor elevation must be provided on the plot plan. *Can you please double check the garage floor elevation.
Misc
Resolved
06/23/2017

*Can you provide the walkout location and LAG.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $907.43 $907.43 Paid 06/29/2017
8331507-Sewer Connection Fee $450.00 $450.00 Paid 06/29/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 06/29/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 06/29/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/29/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/30/2017 6/30/2017 06/30/2017
Underslab Plumbing Inspection - Residential Passed 7/17/2017 7/17/2017 07/17/2017
Piers/Caissons Inspection - Residential Passed 8/7/2017 (10:15) 8/7/2017 08/07/2017
Sewer Service Inspection - R Passed 8/31/2017 08/31/2017
Water Service Inspection - R Partial 8/31/2017 08/31/2017
Water Service Inspection - R Passed 9/7/2017 (10:30) 9/7/2017 09/07/2017
Erosion Control Inspection Residential Passed 9/19/2017 09/19/2017
Electrical Service Inspection Passed 9/19/2017 9/19/2017 at 9:35 AM 09/19/2017
Gas Service Inspection - Residential Passed 9/19/2017 9/19/2017 at 9:40 AM 09/19/2017
All Rough Inspection - Residential Failed 9/19/2017 9/19/2017 at 9:45 AM 09/19/2017
Misc
Corrective Action Required
09/19/2017
FRAMING: -SEAL THE WALL AT STOOP FLASHING -NAIL CEILING BEAM HANGERS ABOVE MASTER BED -NAIL CORNER STUDS W/ 16D@12" OC OR EQUIVALENCE -SUPPORT LVL END LOAD AT STAIR LIGHT SWITCH. EITHER ADD JOIST UNDERNEATH OR HANG IT TO THE 2X CROSS BEAM -AT REAR BEDROOM CLOSET: OVERNOTCHED STUDS; FIREBLOCK WALL FROM JOIST SPACE -FIREBLOCK WALL SPACE FROM I BEAM FURDOWN SPACE AT BOTH SIDE OF REAR BASEMENT BED -BLOCK BASEMENT WALKOUT DOOR PER SECURITY CODE ELECTRICAL: -PAN OFF THE ELECTRICAL INSIDE THE RETURN AIR SPACE AT MASTER BED/TOILET WALL -INSTALL LIGHT OUTSIDE BASEMENT BEDS AND ISOLATE FROM RETURN AIR SPACE -PROVIDE BASEMENT REAR WALL RECEPTACLE SPACING PER CODE **OK TO INSULATE
All Rough Inspection - Residential Passed 9/26/2017 9/26/2017 at 10:00 AM 09/26/2017
Misc
Resolved
09/26/2017
FRAMING: -SEAL THE WALL AT STOOP FLASHING -NAIL CEILING BEAM HANGERS ABOVE MASTER BED -NAIL CORNER STUDS W/ 16D@12" OC OR EQUIVALENCE -SUPPORT LVL END LOAD AT STAIR LIGHT SWITCH. EITHER ADD JOIST UNDERNEATH OR HANG IT TO THE 2X CROSS BEAM -AT REAR BEDROOM CLOSET: OVERNOTCHED STUDS; FIREBLOCK WALL FROM JOIST SPACE -FIREBLOCK WALL SPACE FROM I BEAM FURDOWN SPACE AT BOTH SIDE OF REAR BASEMENT BED -BLOCK BASEMENT WALKOUT DOOR PER SECURITY CODE ELECTRICAL: -PAN OFF THE ELECTRICAL INSIDE THE RETURN AIR SPACE AT MASTER BED/TOILET WALL -INSTALL LIGHT OUTSIDE BASEMENT BEDS AND ISOLATE FROM RETURN AIR SPACE -PROVIDE BASEMENT REAR WALL RECEPTACLE SPACING PER CODE **OK TO INSULATE
Driveway Inspection Partial 10/23/2017 10/23/2017 at 1:30 PM 10/23/2017
Driveway Inspection Passed 10/26/2017 at 2:20 PM 10/26/2017
Occupancy Inspection - Codes Residential Temporary C of O 12/27/2017 12/27/2017 at 8:50 AM 12/27/2017
Misc
Corrective Action Required
12/27/2017
-USE GALVALNIZED NAILS FOR DECK JOIST HANGERS -REMOVE COVER FROM SMOKE ALARM IN MECHANICAL SPACE -CAP OFF OPEN WATER HEATER B-VENT
Occupancy Inspection - Codes Residential Full C of O 1/4/2018 1/4/2018 at 8:15 AM 01/04/2018
Misc
Resolved
01/04/2018
-REMOVE COVER FROM SMOKE ALARM IN MECHANICAL SPACE -CAP OFF OPEN WATER HEATER B-VENT
Documents & Images
Date Uploaded File Type Document Name
06/20/2017 Letter Codes Residential Plan Review
06/29/2017 Receipt Receipt for transaction: 2017-004472
06/29/2017 Letter Codes Building Permit
06/30/2017 Letter Inspection Summary
07/03/2017 Plans DOC070317-003
07/17/2017 Letter Inspection Summary
08/07/2017 Letter Inspection Summary
08/31/2017 Letter Inspection Summary
09/07/2017 Letter Inspection Summary
09/19/2017 Letter Inspection Summary
09/26/2017 Letter Inspection Summary
12/27/2017 Letter Codes Temporary Certificate of Occupancy
01/04/2018 Letter Field Certificate of Occupancy
01/05/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents