Permit Application Status

PRRES20171770


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20171770
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE STOP WORK ORDER generated on 08/24/2017 12:00 AM by username 'Dale Carter'. STOP WORK ORDER removed on 08/28/2017 12:00 AM by username 'Dale Carter'.
05/31/2017
06/02/2017
09/22/2021
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/02/2017 06/02/2017
Kim Brennan
As-graded plot plan
Resolved
06/02/2017

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Please add in a bubble " AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING"
Spot elevations
Resolved
06/02/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Can you please double check the SE side of the house I am getting a 1.5% slope off the high point. May have to raise the high point.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,176.54 $1,176.54 Paid 06/02/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/02/2017
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 06/02/2017
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/02/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 06/02/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 06/02/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/13/2017 (2:45) 6/13/2017 06/13/2017
Underslab Plumbing Inspection - Residential Passed 7/13/2017 7/13/2017 07/13/2017
Suspended Slab Inspection Not Ready 7/26/2017 7/26/2017 07/26/2017
Misc
Corrective Action Required
07/26/2017
INSPECTION DENIED - EROSION CONTROL
Erosion Control Inspection Residential Failed 7/26/2017 07/26/2017
Suspended Slab Inspection Passed 7/28/2017 (9:30) 7/28/2017 07/28/2017
Misc
Resolved
07/28/2017
INSPECTION DENIED - EROSION CONTROL
Erosion Control Inspection Residential Failed 8/18/2017 at 10:15 AM 08/18/2017
Misc
Corrective Action Required
08/18/2017
COMPLIANT CONSTRUCTION ACCESS NEEDS TO BE INSTALLED. STORM INLET PROTECTION NEEDS TO BE MAINTAINED. STREET CLEANUP REQUIRED. 2 DAYS TO COMPLY OR A STOP WORK ORDER WILL BE POSTED.
Erosion Control Inspection Residential Failed 8/22/2017 at 9:00 AM 08/22/2017
Misc
Corrective Action Required
08/18/2017
COMPLIANT CONSTRUCTION ACCESS NEEDS TO BE INSTALLED. STORM INLET PROTECTION NEEDS TO BE MAINTAINED. STREET CLEANUP REQUIRED. 2 DAYS TO COMPLY OR A STOP WORK ORDER WILL BE POSTED.
Erosion Control Inspection Residential Failed 8/24/2017 at 9:45 AM 08/24/2017
Misc
Corrective Action Required
08/22/2017
8/24: Items identified on 8/22 have not been corrected. Posted Stop Work Order; discussed with Superintendent on-site. 8/22: COMPLIANT CONSTRUCTION ACCESS NEEDS TO BE INSTALLED. STORM INLET PROTECTION NEEDS TO BE MAINTAINED. STREET CLEANUP REQUIRED. 2 DAYS TO COMPLY OR A STOP WORK ORDER WILL BE POSTED.
Erosion Control Inspection Residential Partial 8/28/2017 at 3:05 PM 08/28/2017
Sewer Service Inspection - R Partial 8/31/2017 at 1:35 AM 08/31/2017
Misc
Corrective Action Required
08/31/2017
OK to backfill from foundation, out approximately 25'.
Water Service Inspection - R Passed 9/5/2017 at 10:40 AM 09/05/2017
Sewer Service Inspection - R Passed 9/5/2017 (9:45) 9/5/2017 at 10:35 AM 09/05/2017
Misc
Resolved
09/05/2017
OK to backfill from foundation, out approximately 25'.
Gas Piping Inspection - Residential Failed 9/8/2017 9/8/2017 at 11:55 AM 09/08/2017
Misc
Corrective Action Required
09/08/2017
Pressure OK. Failed because gas line not bonded.
Piers/Caissons Inspection - Residential Passed 9/14/2017 (9:00) 9/14/2017 at 9:20 AM 09/14/2017
Driveway Inspection Partial 9/22/2017 9/22/2017 at 9:55 AM 09/22/2017
Informational
09/22/2017
Tom Chandler 09/22/2017 9:54 AM Inspected forms and compacted aggregate only.
Electrical Service Inspection Passed 9/22/2017 9/22/2017 at 9:20 AM 09/22/2017
Erosion Control Inspection Residential Failed 9/22/2017 at 9:30 AM 09/22/2017
Misc
Corrective Action Required
08/24/2017
Erosion control needs maintenance, including over storm drain inlet to west.
Gas Piping Inspection - Residential Passed 9/22/2017 at 9:35 AM 09/22/2017
Misc
Resolved
09/22/2017
Pressure OK. Failed because gas line not bonded.
Gas Service Inspection - Residential Passed 9/22/2017 9/22/2017 at 9:40 AM 09/22/2017
All Rough Inspection - Residential Failed 9/22/2017 9/22/2017 at 9:50 AM 09/22/2017
Misc
Corrective Action Required
09/22/2017
1. Maintain erosion control, including over storm drain to west; and remove debris and overgrown weeds before further inspection. 2. BSMT: Stub for future plumbing vent. 3. BSMT: Support DWV. 4. BSMT: Anchor columns. 5. BSMT: Shim full-width of steel beams. 6. 1st FLR: Cut joist and missing hangers at rear of Breakfast Nook. 7. 1st FLR: Block joists at wall, per plans, at cantelevers (flex room, pantry, & dining room). 8. 1st FLR: Firestopping along all of rear garage wall. 9. 1st FLR: Firestop under tub over garage. 10. 1st FLR: Support bottom of stair stringers. 11. 1st FLR: 7 studs under southwest end of beam over kitchen. 12. 1st FLR: Glazing at stair landing should be tempered. 13. 2nd FLR: Block joists at load-bearing walls, per plans. 14. 2nd FLR: Nail hangers over bath. 15. 2nd FLR: Missing hangers over entrance to BR#3. 16. 2nd FLR: BOCA plate at BR#3. 17. 2nd FLR: Missing hangers at ceiling coffer over BR#3. 18. 2nd FLR: 3 studs under both ends of LVL at BR#4. 19. 2nd FLR: Protect NM within 6' of attic access. 20. 2nd FLR: BOCA plate at Master Bath. 21. 2nd FLR: Nail rafter hangers over Master Bath. 22. 2nd FLR: Slope DWV in attic. 23. 2nd FLR: Jack-studs under header that supports roof ridge, at small window in front gable.
Sidewalk Inspection Partial 9/25/2017 9/25/2017 at 9:30 AM 09/25/2017
Informational
09/25/2017
Tom Chandler 09/25/2017 9:38 AM Inspected forms and compacted aggregate only. Inspected west side of sidewalk from ADA ramp at the corner to west edge of lot. Will do rest of sidewalk at later date. Need to check on property line to the south of lot 114.
Driveway Inspection Passed 9/25/2017 at 9:30 AM 09/25/2017
Informational
09/25/2017
Tom Chandler 09/25/2017 9:42 AM Driveway has been completed and passed final inspection.
All Rough Inspection - Residential Failed 9/28/2017 9/28/2017 at 9:35 AM 09/28/2017
Misc
Corrective Action Required
09/22/2017
5. BSMT: Shim full-width of steel beams. 8. 1st FLR: Firestopping along all of rear garage wall. 9. 1st FLR: Firestop under tub over garage. 13. 2nd FLR: Block joists at load-bearing walls, per plans. 16. 2nd FLR: BOCA plate at BR#3. 17. 2nd FLR: Missing hangers at ceiling coffer over BR#3. *Hangers now in place, but not nailed. 18. 2nd FLR: 3 studs under both ends of LVL at BR#4. 22. 2nd FLR: Slope DWV in attic.
Sidewalk Inspection Partial 9/28/2017 at 2:45 PM 09/28/2017
Informational
09/28/2017
Tom Chandler 09/28/2017 2:51 PM Sidewalk on west side of ADA ramp has been completed and passed final inspection. Will complete the remainder of sidewalk on east side of lot in the future.
All Rough Inspection - Residential Passed 9/29/2017 9/29/2017 at 11:30 AM 09/29/2017
Misc
Resolved
09/29/2017
5. BSMT: Shim full-width of steel beams. 8. 1st FLR: Firestopping along all of rear garage wall. 9. 1st FLR: Firestop under tub over garage. 13. 2nd FLR: Block joists at load-bearing walls, per plans. 16. 2nd FLR: BOCA plate at BR#3. 17. 2nd FLR: Missing hangers at ceiling coffer over BR#3. *Hangers now in place, but not nailed. 18. 2nd FLR: 3 studs under both ends of LVL at BR#4. 22. 2nd FLR: Slope DWV in attic.
Sidewalk Inspection Partial 10/27/2017 10/27/2017 at 10:00 AM 10/27/2017
PW-Misc
Informational
10/27/2017
Matt Munger 10/27/2017 10:43 AM Forms were set to meet ADA standards and gravel was compacted properly. Dan is going to use Isolation Joint material in the areas that we specified.
Sidewalk Inspection Partial 10/31/2017 at 2:45 PM 10/31/2017
PW-Misc
Informational
10/27/2017
Matt Munger 10/27/2017 10:43 AM Forms were set to meet ADA standards and gravel was compacted properly. Dan is going to use Isolation Joint material in the areas that we specified. Tom Chandler 10/31/2017 2:47 PM Looks ready to pour.
Sidewalk Inspection Passed 11/6/2017 at 10:15 AM 11/06/2017
PW-Misc
Informational
10/31/2017
Matt Munger 10/27/2017 10:43 AM Forms were set to meet ADA standards and gravel was compacted properly. Dan is going to use Isolation Joint material in the areas that we specified. Tom Chandler 10/31/2017 2:47 PM Looks ready to pour. Tom Chandler 11/06/2017 10:18 AM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Temporary C of O 2/27/2018 at 9:30 AM 02/27/2018
Misc
Corrective Action Required
02/27/2018
- used as a model sales office. recall for Final inspection when office/ sales office is removed and turned back into a garage. As graded plot plan required ok for TCO
Occupancy Inspection - Codes Residential Failed 9/17/2019 09/17/2019
Misc
Corrective Action Required
02/27/2018
- used as a model sales office. recall for Final inspection when office/ sales office is removed and turned back into a garage. ** Missing fire separation from garage to living space. Door sized opening framed and insulated but not sheetrocked. ** Submit As-graded Plot Plan.
Plot Plan Inspection Failed 10/2/2020 10/02/2020
Misc
Corrective Action Required
10/02/2020
- SAN MAN HOLE C-2, E SIDE, NOT FOUND ON LOT AS SHOWN ON PLOT PLAN -
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Misc
Resolved
09/22/2021
- used as a model sales office. recall for Final inspection when office/ sales office is removed and turned back into a garage. ** Missing fire separation from garage to living space. Door sized opening framed and insulated but not sheetrocked. ** Submit As-graded Plot Plan.
Documents & Images
Date Uploaded File Type Document Name
06/02/2017 Receipt Receipt for transaction: 2017-003379
06/02/2017 Letter Codes Building Permit
06/05/2017 Plot Plan DOC060517-002
06/13/2017 Letter Inspection Summary
07/13/2017 Letter Inspection Summary
07/26/2017 Letter Inspection Summary
07/28/2017 Letter Inspection Summary
08/24/2017 Letter Stop Work Order
08/28/2017 Letter Inspection Summary
08/31/2017 Letter Inspection Summary
09/05/2017 Letter Inspection Summary
09/08/2017 Letter Inspection Summary
09/14/2017 Letter Inspection Summary
09/22/2017 Letter DE-Daily Inspection Summary
09/22/2017 Letter Inspection Summary
09/25/2017 Letter DE-Daily Inspection Summary
09/28/2017 Letter Inspection Summary
09/28/2017 Letter DE-Daily Inspection Summary
09/29/2017 Letter Inspection Summary
10/27/2017 Letter DE-Daily Inspection Summary
10/31/2017 Letter DE-Daily Inspection Summary
11/06/2017 Letter DE-Daily Inspection Summary
02/27/2018 Letter Codes Temporary Certificate of Occupancy
09/17/2019 Letter INSPECTION SUMMARY
10/01/2020 Plot Plan APPROVED AS-BUILT
10/02/2020 Letter INSPECTION SUMMARY
02/19/2021 Letter Codes 140 Day Letter
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents