Permit Application Status

PRRES20171753


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20171753
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT STOP WORK ORDER generated on 07/06/2017 12:00 AM by username 'Mitch Plemmons'. STOP WORK ORDER removed on 09/13/2017 12:00 AM by username 'Dale Carter'.
05/30/2017
06/02/2017
06/13/2018
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/01/2017 05/31/2017
Nick Lightner
Spot elevations
Resolved
05/31/2017

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *Double check the slope on the W and N side of the house.
As-graded plot plan
Resolved
05/31/2017

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add in a bubble "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING"
Residential Plan Review Approved 06/01/2017 05/30/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,176.54 $1,176.54 Paid 06/02/2017
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 06/02/2017
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/02/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 06/02/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 06/02/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/02/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/13/2017 (2:45) 6/13/2017 06/13/2017
Erosion Control Inspection Residential Failed 07/06/2017
Erosion Control Inspection Residential Failed 7/10/2017 07/10/2017
Misc
Corrective Action Required
07/10/2017
7/10/2017: Come silt fence has been installed, but not enough.
Underslab Plumbing Inspection - Residential Passed 7/25/2017 7/25/2017 07/25/2017
Erosion Control Inspection Residential Partial 9/13/2017 9/13/2017 07/25/2017
Misc
Corrective Action Required
07/11/2017
7/10/2017: Come silt fence has been installed, but not enough.
Gas Piping Inspection - Residential Not Ready 8/15/2017 8/15/2017 08/15/2017
Misc
Corrective Action Required
08/15/2017
no building, foundation only scheduled for gas inspection.
Suspended Slab Inspection Passed 9/13/2017 at 8:55 AM 09/13/2017
Erosion Control Inspection Residential Partial 9/13/2017 at 2:35 AM 09/13/2017
Partial Correction
09/13/2017
Erosion control is compliant, but will need maintenance.
Piers/Caissons Inspection - Residential Passed 9/14/2017 (9:00) 9/14/2017 at 9:10 AM 09/14/2017
Sewer Service Inspection - R Passed 9/19/2017 (9:45) 9/19/2017 at 10:05 AM 09/19/2017
Water Service Inspection - R Partial 9/19/2017 at 10:10 AM 09/19/2017
Water Service Inspection - R Passed 9/20/2017 at 9:00 AM 09/20/2017
Gas Service Inspection - Residential Failed 9/27/2017 9/27/2017 at 12:45 PM 09/27/2017
Misc
Corrective Action Required
09/27/2017
REPAIR SILT FENCE AT FRONT, ADD GRAVEL TO ENTRANCE DRIVE, & PERFORM STREET CLEAN-UP BEFORE FURTHER INSPECTION. 1. No pressure. 2. Bond gas pipe.
Erosion Control Inspection Residential Failed 9/27/2017 at 12:50 PM 09/27/2017
Misc
Corrective Action Required
09/13/2017
REPAIR SILT FENCE AT FRONT, ADD GRAVEL TO ENTRANCE DRIVE, & PERFORM STREET CLEAN-UP BEFORE FURTHER INSPECTION.
Gas Piping Inspection - Residential Passed 10/2/2017 10/2/2017 at 1:40 AM 10/02/2017
Misc
Resolved
10/02/2017
no building, foundation only scheduled for gas inspection.
Gas Service Inspection - Residential Passed 10/2/2017 at 1:45 AM 10/02/2017
Misc
Resolved
10/02/2017
REPAIR SILT FENCE AT FRONT, ADD GRAVEL TO ENTRANCE DRIVE, & PERFORM STREET CLEAN-UP BEFORE FURTHER INSPECTION. 1. No pressure. 2. Bond gas pipe.
Electrical Service Inspection Passed 10/18/2017 10/18/2017 at 10:50 AM 10/18/2017
All Rough Inspection - Residential Failed 10/18/2017 10/18/2017 at 11:00 AM 10/18/2017
Misc
Corrective Action Required
10/18/2017
1. Perform street clean-up before further inspection. 2. BSMT: Anchor columns. 3. BSMT: Shim full-width of beams. 4. BSMT & 1st FLR: Firestop stair landings (vert-to-horiz). 5. BSMT & 1st FLR: Support bottoms of stair stringers, at landings. 6. BSMT & 1st FLR: (7) studs at point load beside stair landing. 7. 1st FLR: Sill-plate anchors in garage. 8. 1st FLR: Solid-block beside main duct, inside chase (loosely suspended insulation is not adequate). 9. 1st & 2nd FLR: Nail all joist hangers. 10. 2nd FLR: Install snow-blocking. 11. ROOF: Missing ridge and purlin supports over the southeast and the southwest bedrooms. 12. ROOF: Purlin struts along the south side of the house are not constructed in a 'T' configuration, as required on the plans.
All Rough Inspection - Residential Failed 10/20/2017 10/20/2017 at 11:00 AM 10/20/2017
Misc
Corrective Action Required
10/18/2017
11. ROOF: Missing ridge and purlin supports over the southeast bedroom. *Builder reportedly changed this to a vaulted ceiling - submit revised plans or letter approving framing as-constructed. OK to insulate.
Driveway Inspection Partial 12/14/2017 at 2:05 PM 12/13/2017
Informational
12/13/2017
Tom Chandler 12/13/2017 2:08 PM Inspected forms and compacted aggregate only.
Driveway Inspection Passed 12/18/2017 at 10:30 AM 12/20/2017
Informational
12/20/2017
Tom Chandler 12/20/2017 10:31 AM Driveway has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Not Ready 2/27/2018 at 9:00 AM 02/27/2018
Misc
Corrective Action Required
02/27/2018
not ready no address or front lights .recall
Plot Plan Inspection Passed 3/9/2018 at 10:00 AM 03/09/2018
Occupancy Inspection - Codes Residential Failed 4/26/2018 4/26/2018 at 7:00 AM 04/26/2018
Misc
Corrective Action Required
02/27/2018
- LAWN SPRINKLER PERMIT - INCORRECT PIPING AT WATER HEATER DISCHARGE -NO BSMT HANDRAIL, NEEDS TO EXTEND TO LAST STEP. -OPEN LIGHTS IN MSTR CLOSET. -OPEN WIRING UNDER FRONT PORCH. -NO EGRESS LADDER -LABEL SMOKES AT PANEL. - SEAL BSMT AT I BEAM FROM GARAGE AT TOP OF FOUNDATION WITH FIRE CAULK.
Occupancy Inspection - Codes Residential Temporary C of O 5/29/2018 at 9:45 AM 05/29/2018
Misc
Corrective Action Required
04/26/2018
- LAWN SPRINKLER PERMIT - INCORRECT PIPING AT WATER HEATER DISCHARGE -NO BSMT HANDRAIL, NEEDS TO EXTEND TO LAST STEP. -OPEN LIGHTS IN MSTR CLOSET. -OPEN WIRING UNDER FRONT PORCH. -NO EGRESS LADDER -LABEL SMOKES AT PANEL. - SEAL BSMT AT I BEAM FROM GARAGE AT TOP OF FOUNDATION WITH FIRE CAULK.
Misc
Corrective Action Required
05/29/2018
LADDER NEEDED IN BASEMENT EGRESS WINDOW WELL.
Occupancy Inspection - Codes Residential Temporary C of O 6/11/2018 6/11/2018 at 8:00 AM 06/11/2018
Misc
Corrective Action Required
05/29/2018
- LAWN SPRINKLER PERMIT - INCORRECT PIPING AT WATER HEATER DISCHARGE -NO BSMT HANDRAIL, NEEDS TO EXTEND TO LAST STEP. -OPEN LIGHTS IN MSTR CLOSET. -OPEN WIRING UNDER FRONT PORCH. -NO EGRESS LADDER -LABEL SMOKES AT PANEL. - SEAL BSMT AT I BEAM FROM GARAGE AT TOP OF FOUNDATION WITH FIRE CAULK.
Misc
Corrective Action Required
05/29/2018
LADDER NEEDED IN BASEMENT EGRESS WINDOW WELL.
Misc
Corrective Action Required
06/11/2018
SPRINKLER PERMIT NEEDED.
All Rough Inspection - Residential Passed 6/13/2018 at 7:30 AM 06/13/2018
Misc
Corrective Action Required
10/20/2017
11. ROOF: Missing ridge and purlin supports over the southeast bedroom. *Builder reportedly changed this to a vaulted ceiling - submit revised plans or letter approving framing as-constructed. OK to insulate.
Occupancy Inspection - Codes Residential Full C of O 6/13/2018 6/13/2018 at 7:30 AM 06/13/2018
Misc
Corrective Action Required
06/11/2018
- LAWN SPRINKLER PERMIT - INCORRECT PIPING AT WATER HEATER DISCHARGE -NO BSMT HANDRAIL, NEEDS TO EXTEND TO LAST STEP. -OPEN LIGHTS IN MSTR CLOSET. -OPEN WIRING UNDER FRONT PORCH. -NO EGRESS LADDER -LABEL SMOKES AT PANEL. - SEAL BSMT AT I BEAM FROM GARAGE AT TOP OF FOUNDATION WITH FIRE CAULK.
Misc
Corrective Action Required
06/11/2018
LADDER NEEDED IN BASEMENT EGRESS WINDOW WELL.
Misc
Corrective Action Required
06/11/2018
SPRINKLER PERMIT NEEDED.
Documents & Images
Date Uploaded File Type Document Name
06/02/2017 Receipt Receipt for transaction: 2017-003380
06/02/2017 Letter Codes Building Permit
06/05/2017 Plot Plan DOC060517-003
06/13/2017 Letter Inspection Summary
07/06/2017 Letter Stop Work Order
07/10/2017 Letter Inspection Summary
07/25/2017 Letter Inspection Summary
08/15/2017 Letter Inspection Summary
09/13/2017 Letter Inspection Summary
09/13/2017 Letter Inspection Summary
09/14/2017 Letter Inspection Summary
09/19/2017 Letter Inspection Summary
09/20/2017 Letter Inspection Summary
09/27/2017 Letter Inspection Summary
10/02/2017 Letter Inspection Summary
10/18/2017 Letter Inspection Summary
10/20/2017 Letter Inspection Summary
12/13/2017 Letter DE-Daily Inspection Summary
12/20/2017 Letter DE-Daily Inspection Summary
02/27/2018 Letter Inspection Summary
03/09/2018 Letter Inspection Summary
03/09/2018 Plot Plan As graded Plot Plan
04/26/2018 Letter Inspection Summary
06/11/2018 Letter Codes Temporary Certificate of Occupancy
06/13/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home