Permit Application Status

PRRES20170989


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20170989
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK FINISHED BASEMENT
04/04/2017
04/28/2017
10/09/2017
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 04/06/2017 04/05/2017
Shannon McGuire
Residential Plan Review Approved 04/06/2017 04/05/2017
Jonathon Hilton
Plot Plan Review Approved 04/06/2017 04/04/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $855.94 $855.94 Paid 04/28/2017
8331507-Sewer Connection Fee $360.00 $360.00 Paid 04/28/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 04/28/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 04/28/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 04/28/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/4/2017 (9:00) 5/4/2017 05/04/2017
Underslab Plumbing Inspection - Residential Failed 5/19/2017 5/19/2017 05/19/2017
Misc
Corrective Action Required
05/19/2017
***INSPECTION DENIED DUE TO LACK OF EROSION CONTROL
Piers/Caissons Inspection - Residential Passed 6/7/2017 6/7/2017 06/07/2017
Sewer Service Inspection - R Passed 6/19/2017 (10:45) 6/19/2017 06/19/2017
Water Service Inspection - R Passed 6/21/2017 (11:30) 6/21/2017 06/21/2017
Electrical Service Inspection Passed 7/7/2017 7/7/2017 07/07/2017
Gas Service Inspection - Residential Passed 7/7/2017 7/7/2017 07/07/2017
All Rough Inspection - Residential Failed 7/7/2017 7/7/2017 07/07/2017
Misc
Corrective Action Required
07/07/2017
***RESTORE EROSION CONTROL ALONG THE STREET. FRAMING: -IN GARAGE/STOOP WALL WHERE THE SHORTER WALL MEET THE TALLER WALL, NAIL BOTH STUDS TOGETHER -CHECK ALL AND NAIL CORNER STUDS WITH 16D@12" OC OR EQUIVALENT NAILING -BLOCK DECK DOOR PER SECURITY CODE -INSTALL BLOCKING BETWEEN LAPPED JOISTS ABOVE I BEAMS -WINDOW SIZE ALONG THE REAR BRACE WALL LINES (BOTH MAIN FLOOR AND BASEMENT) ARE NOT PER PLAN. HAVE ARCHITECT ADDRESS BRACE WALL COMPLIANCE PER IRC 602.10.2&3 ELECTRICAL: -INSTALL A RECEPTACLE AT REAR OF HOUSE, ACCESSIBLE FROM AND WITHIN 6.5 FT OF GRADE MECHANICAL: -CONNECT DUCT TO BASEMENT BATH FAN ***OK TO INSULATE
Underslab Plumbing Inspection - Residential Passed 07/13/2017
Misc
Resolved
07/13/2017
***INSPECTION DENIED DUE TO LACK OF EROSION CONTROL
All Rough Inspection - Residential Partial 7/13/2017 7/13/2017 07/13/2017
Misc
Corrective Action Required
07/07/2017
-WINDOW SIZE ALONG THE REAR BRACE WALL LINES (BOTH MAIN FLOOR AND BASEMENT) ARE NOT PER PLAN. HAVE ARCHITECT ADDRESS BRACE WALL COMPLIANCE PER IRC 602.10.2&3 ***OK TO ROCK IF THE ARCHITECT OK THE ABOVE
Driveway Inspection Passed 8/10/2017 8/10/2017 08/09/2017
Sidewalk Inspection Passed 8/10/2017 8/10/2017 08/09/2017
All Rough Inspection - Residential Passed 10/02/2017
Misc
Resolved
10/02/2017
-WINDOW SIZE ALONG THE REAR BRACE WALL LINES (BOTH MAIN FLOOR AND BASEMENT) ARE NOT PER PLAN. HAVE ARCHITECT ADDRESS BRACE WALL COMPLIANCE PER IRC 602.10.2&3 ***OK TO ROCK IF THE ARCHITECT OK THE ABOVE
Occupancy Inspection - Codes Residential Failed 10/2/2017 10/2/2017 at 8:55 AM 10/02/2017
Misc
Corrective Action Required
10/02/2017
-OBTAIN LAWN IRRIGATION PERMIT -EXPOSE WATER METER. TOP OF METER-TO-LID DISTANCE MUST BE 14"-18" -FINAL GRADE, SOD, SPLASHBLOCKS -PROVIDE MIN. 6" CLEARANCE FROM BOTTOM WINDOW TRIM TO FINAL GRADE -SEAL EXTERIOR WALL PENETRATIONS, ABOVE METER AND AC DISCONNECT, ETC -DECK: LAG DECK LEDGE BOARD TO HOUSE RIM BAND; SUPPORT THE INNER PLY OF DECK BEAM TO OUTER POSTS WITH PROPER DEVICE -EXPOSE THE FLOOR RECEPTACLE AT STAIR GUARDRAIL -INSTALL WINDOW CRANKS FOR ALL BEDROOMS -INSTALL LOCK DEVICE FOR OVEN BREAKER -CANNOT CONNECT WASTE DRAIN TO SEWER CLEANOUT. VERIFY THAT THE FITTING UNDERNEATH IS NOT A TEE/S-TEE FITTING
Occupancy Inspection - Codes Residential Temporary C of O 10/5/2017 10/5/2017 at 8:15 AM 10/05/2017
Misc
Corrective Action Required
10/02/2017
-DECK: LAG DECK LEDGE BOARD TO HOUSE RIM BAND
Occupancy Inspection - Codes Residential Full C of O 10/9/2017 10/9/2017 at 11:00 AM 10/09/2017
Misc
Resolved
10/09/2017
-DECK: LAG DECK LEDGE BOARD TO HOUSE RIM BAND
Documents & Images
Date Uploaded File Type Document Name
04/28/2017 Receipt Receipt for transaction: 2017-001646
04/28/2017 Letter Codes Building Permit
05/01/2017 Plot Plan DOC050117-005
05/04/2017 Letter Inspection Summary
05/19/2017 Letter Inspection Summary
06/07/2017 Letter Inspection Summary
06/19/2017 Letter Inspection Summary
06/21/2017 Letter Inspection Summary
07/07/2017 Letter Inspection Summary
07/13/2017 Letter Inspection Summary
07/25/2017 Engineer Report/Study 1691 NE PARKWOOD DR
08/09/2017 Letter Inspection Summary
08/09/2017 Letter Inspection Summary
10/02/2017 Letter Inspection Summary
10/05/2017 Letter Codes Temporary Certificate of Occupancy
10/09/2017 Letter Field Certificate of Occupancy
10/13/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents