Permit Application Status

PRRES20170595


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20170595
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK
03/07/2017
03/13/2017
04/24/2018
Locations
Contacts
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
SDI ELECTRIC, LLC, Address:3317 W 81ST ST, Phone:(913) 636-5021  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/09/2017 03/09/2017
Nick Lightner
Residential Plan Review Approved 03/09/2017 03/07/2017
Kim Brennan
Plot Plan Review (P&D) Approved 03/09/2017 03/07/2017
Shannon McGuire
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,199.95 $1,199.95 Paid 03/13/2017
Right of Way Permit Fee $75.00 $75.00 Paid 03/13/2017
8331507-Sewer Connection Fee $570.00 $570.00 Paid 03/13/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 03/13/2017
Water Meter Fee $405.36 $405.36 Paid 03/13/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/17/2017 3/17/2017 03/17/2017
Sewer Service Inspection - R Passed 3/28/2017 (11:00) 3/28/2017 03/28/2017
Water Service Inspection - R Passed 3/28/2017 (1:00) 3/28/2017 03/28/2017
Underslab Plumbing Inspection - Residential Failed 4/11/2017 04/11/2017
Corrective Action Required
04/11/2017
-VENT THE SHOWER TRAP
Underslab Plumbing Inspection - Residential Passed 4/12/2017 4/12/2017 04/12/2017
Piers/Caissons Inspection - Residential Passed 4/12/2017 (1:00) 4/12/2017 04/12/2017
Erosion Control Inspection Residential Failed 6/20/2017 06/20/2017
Corrective Action Required
06/20/2017
Site lacks erosion control - silt fence down on the east perimeter of the lot, dirt on the street (Gateway Dr)
All Rough Inspection - Residential Not Ready 8/4/2017 8/4/2017 08/04/2017
Misc
Corrective Action Required
08/04/2017
IBC 109.1, 109.5; IRC R109.3 INSPECTION ACCESS: PROPERTY LOCKED; INTERIOR NOT ACCESSIBLE. CALL FOR INSPECTION ON DAY WHEN JOBSITE IS ACCESSIBLE.
Electrical Service Inspection Failed 8/7/2017 8/7/2017 08/07/2017
Misc
Corrective Action Required
08/07/2017
-BOND THE METAL RACEWAY BETWEEN METER BOX AND SERVICE DISCONNECT PER 250.92. INSTALL BONDING BUSHING/LOCKNUT AND USE #4 CU BONDING JUMPER -INSTALL A MIN. #4 CU MAIN BONDING JUMPER CONNECTING THE BUS BAR, WHERE THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO, TO THE LOWER GROUNDING BUS BAR WHERE THE GROUNDING ELECTRODE CONDUCTOR IS CONNECTED TO.
Erosion Control Inspection Residential Failed 8/7/2017 08/07/2017
Misc
Corrective Action Required
08/07/2017
-REPLACE DAMAGED EROSION CONTROL ALONG GATEWAY DR. SILT FENCE HAS HOLES AT BOTTOM ALLOWING MUD FLOWING ONTO THE STREET -CLEAN MUD OFF THE STREET
Gas Service Inspection - Residential Passed 8/7/2017 8/7/2017 08/07/2017
All Rough Inspection - Residential Failed 8/7/2017 8/7/2017 08/07/2017
Misc
Corrective Action Required
08/04/2017
***CORRECT THE EROSION CONTROL AND CLEAN THE STREET FRAMING: -PLAN ON SITE. MAKE SURE EXTERIOR BRACE WALLS ARE PER PLAN -ANCHOR SILL PLATES PER CODE: TIGHTEN ALL ANCHOR NUTS; ANCHOR WITHIN 12" OGF SILL BREAKS; RE-ANCHOR OUT-OF-PLATE ANCHORS AT REAR GARAGE WALL -NAIL ALL CORNER STUDS PER CODE. 16D @ 12" OC OR EQUIVALENT NAILING -ONE WINDOW AT REAR DINING ROOM DOES NOT COMPLY WITH FALL PROTECTION REQUIREMENT -FIREBLOCKING: FB FLOOR AT TRAP; FB LAUNDRY WALL FROM ROOF; FIRESTOP ALL PENETRATIONS OF CEILING RETURN AIR SPACE -PROVIDE MIN. 1.5" OF BEARING UNDER NOTCHED JOIST ABOVE THE SEWER CLEANOUT -INSTALL SECURITY BLOCKING FOR BASEMENT WALKOUT DOOR MECHANICAL: -FRAME AND FASTEN FIREPLACE TO FRAME PLUMBING: -AT STAIR WALL, STRAP ON BOTH SIDE OF OVERBORED/CUT-THROUGH TOP PLATES -AT EXTERIOR WALL TOP PLATE WHERE BORED MORE THAN 50%, INSTALL STRAPS -INSTALL STUD SHOE FOR STUD BORED MORE THAN 60% AT LAUNDRY ***OK TO INSULATE
Erosion Control Inspection Residential Partial 8/9/2017 08/09/2017
Misc
Partial Correction
08/09/2017
8/9/17-EROSION CONTROL IN COMPLIANCE
Electrical Service Inspection Passed 8/9/2017 8/9/2017 08/09/2017
Misc
Resolved
08/09/2017
-BOND THE METAL RACEWAY BETWEEN METER BOX AND SERVICE DISCONNECT PER 250.92. INSTALL BONDING BUSHING/LOCKNUT AND USE #4 CU BONDING JUMPER -INSTALL A MIN. #4 CU MAIN BONDING JUMPER CONNECTING THE BUS BAR, WHERE THE SERVICE GROUNDED CONDUCTOR IS CONNECTED TO, TO THE LOWER GROUNDING BUS BAR WHERE THE GROUNDING ELECTRODE CONDUCTOR IS CONNECTED TO.
All Rough Inspection - Residential Failed 8/9/2017 8/9/2017 08/09/2017
Misc
Corrective Action Required
08/07/2017
FRAMING: -ANCHOR SILL PLATES PER CODE: TIGHTEN ALL ANCHOR NUTS; ANCHOR WITHIN 12" OF SILL BREAKS **ANCHOR NEAR THE BASEMENT WALKOUT DOOR -ONE WINDOW AT REAR DINING ROOM DOES NOT COMPLY WITH FALL PROTECTION REQUIREMENT **CHECK ON FINAL -PROVIDE MIN. 1.5" OF BEARING UNDER NOTCHED JOIST ABOVE THE SEWER CLEANOUT **ADD A PIECE OF GREEN SILL PLATE UNDER THE JOIST PLUMBING: -AT EXTERIOR WALL TOP PLATE WHERE BORED MORE THAN 50%, INSTALL STRAPS **STRAP ACROSS THE VENTS ***OK TO INSULATE
All Rough Inspection - Residential Partial 8/14/2017 8/14/2017 08/14/2017
Misc
Corrective Action Required
08/09/2017
-PROVIDE MIN. 1.5" OF BEARING UNDER NOTCHED JOIST ABOVE THE SEWER CLEANOUT **ADD A PIECE OF GREEN SILL PLATE UNDER THE JOIST ***OK TO ROCK
Sidewalk Inspection Failed 10/3/2017 10/03/2017
Corrective Action Required
10/03/2017
Forms have grade breaks (sidewalk forms).
Driveway Inspection Passed 10/4/2017 10/4/2017 10/05/2017
Sidewalk Inspection Partial 10/4/2017 at 11:00 AM 10/05/2017
Informational
10/05/2017
Inspected the forms only. Talked at length about ADA compliance; discussed ADA compliance for the curb ramp and sidewalk.
Sidewalk Inspection Passed 11/30/2017 at 9:25 AM 11/30/2017
All Rough Inspection - Residential Passed 12/11/2017
Misc
Resolved
12/11/2017
-PROVIDE MIN. 1.5" OF BEARING UNDER NOTCHED JOIST ABOVE THE SEWER CLEANOUT **ADD A PIECE OF GREEN SILL PLATE UNDER THE JOIST ***OK TO ROCK
Erosion Control Inspection Residential Passed 12/11/2017
Misc
Resolved
12/11/2017
8/9/17-EROSION CONTROL IN COMPLIANCE
Occupancy Inspection - Codes Residential Failed 12/11/2017 12/11/2017 at 10:30 AM 12/11/2017
Misc
Corrective Action Required
12/11/2017
-GUARDRAIL REQUIRED AT STOOP -DECK: SUPPORT DECK BEAM; LAG DECK LEDGE BOARD THROUGH THE SPACERS; BLOCK GUARDRAIL POST; INSTALL DECK HANGERS AND NAIL ALL HANGERS -SEAL EXTERIOR WALL PENETRATIONS AND LIGHTS -SECURE AC WHIP WITHIN 12" OF DISCONNECT -INSTALL SPLASHBLOCK UNDER SUMP PUMP DISCHARGE -INSTALL OVEN BREAKER LOCK -INSTALL BOTTOM TRACK-SUPPORT BRACKETS FOR GARAGE DOORS -INSTALL SPARKRINGS FOR OUTLET BOXES AT FIREPLACE RECESSED MORE THAN 1/4" BEHIND NON-COMBUSTIBLE WALL SURFACE -DEDICATE SUMP PUMP AND BACKUP RECEPTACLE OUTLET OR PROVIDE GFCI PROTECTION FOR OUTLET -INSTALL DOUBLE-WALL FITTING AT CONNECTION TO COMMON VENT
Occupancy Inspection - Codes Residential Failed 4/23/2018 4/23/2018 at 10:45 AM 04/23/2018
Misc
Corrective Action Required
12/11/2017
-SEAL EXTERIOR LIGHTS -INSTALL SPARKRINGS FOR OUTLET BOXES AT FIREPLACE RECESSED MORE THAN 1/4" BEHIND NON-COMBUSTIBLE WALL SURFACE
Occupancy Inspection - Codes Residential Full C of O 4/24/2018 4/24/2018 at 10:41 AM 04/24/2018
Misc
Resolved
04/24/2018
-SEAL EXTERIOR LIGHTS -INSTALL SPARKRINGS FOR OUTLET BOXES AT FIREPLACE RECESSED MORE THAN 1/4" BEHIND NON-COMBUSTIBLE WALL SURFACE
Documents & Images
Date Uploaded File Type Document Name
03/07/2017 Letter Codes Residential Plan Review
03/13/2017 Receipt Receipt for transaction: 2017-000876
03/13/2017 Letter Codes Building Permit
03/14/2017 Plot Plan DOC031417-002
03/17/2017 Letter Inspection Summary
03/28/2017 Letter Inspection Summary
03/28/2017 Letter Inspection Summary
04/11/2017 Letter Inspection Summary
04/12/2017 Letter Inspection Summary
04/12/2017 Letter Inspection Summary
06/20/2017 Letter Inspection Summary
08/04/2017 Letter Inspection Summary
08/07/2017 Letter Inspection Summary
08/09/2017 Letter Inspection Summary
08/09/2017 Letter Inspection Summary
08/14/2017 Letter Inspection Summary
10/03/2017 Letter Inspection Summary
10/05/2017 Letter Inspection Summary
12/11/2017 Letter Inspection Summary
04/23/2018 Letter Inspection Summary
04/24/2018 Letter Field Certificate of Occupancy
04/25/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home