PRRES20162977
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST REAL EST DEV INC
NEW 3 OR 4 FAMILY
NEW 4 PLEX UNIT
11/17/2016
11/29/2016
01/19/2018
Locations
Contacts
STUCKER CONSTRUCTION INC, Address:1120 NW EAGLE RIDGE BLVD, Phone:(816) 795-1317  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
COMFORT SYSTEMS HTG/CLG, Address:128 W Markey Rd, Phone:(816) 322-1013  
STAR ELECTRICAL, Address:P O BOX 1755, Phone:(816) 694-0982  
HUNT MIDWEST REAL EST DEV INC, Address:8300 NE UNDERGROUND DR  
LEW DARREN & SHIRLEY-TRUSTEES, Address:1509 APPIAN WAY  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 11/21/2016 11/28/2016
Christina Stanton
Plot Plan Review Approved 11/28/2016
Jonathon Smith
Plot Plan Review Rejected 11/21/2016 11/17/2016
Jonathon Smith
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $2,087.83 $2,087.83 Paid 11/29/2016
8331507-Sewer Connection Fee $1,110.00 $1,110.00 Paid 11/29/2016
8331401-Water Tap Fee $13,240.00 $13,240.00 Paid 11/29/2016
8350015-Water Meter Fee $1,621.44 $1,621.44 Paid 11/29/2016
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 11/29/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/28/2016 (2:00) 12/28/2016 12/28/2016
Water Service Inspection - R Partial 1/25/2017 01/25/2017
Underslab Plumbing Inspection - Residential Passed 1/26/2017 (8:00 to 5:00) 1/26/2017 01/25/2017
Underslab Electrical Inspection - Residential Passed 1/26/2017 (8:00 to 5:00) 1/26/2017 01/25/2017
Sewer Service Inspection - R Passed 1/27/2017 01/27/2017
Water Service Inspection - R Passed 2/1/2017 (4:00) 2/1/2017 02/01/2017
Piers/Caissons Inspection - Residential Passed 2/2/2017 (10:00) 2/2/2017 02/02/2017
Electrical Service Inspection Passed 3/21/2017 03/21/2017
Erosion Control Inspection Residential Failed 3/21/2017 03/21/2017
All Rough Inspection - Residential Failed 3/21/2017 03/21/2017
Misc
Corrective Action Required
03/21/2017
- provide plans for inspection -2130 -firestop dryer vent at ceiling. - remove insulation from ceiling of 2 baths on 30-36. - instal secruity blocking -firestop dbl wall construction 1st fllor east wall -2132 support dwv kitching and throughout. - firestop heat duct2 through floor 2 middle units -fireblock furnace room from attic -2134 strap rock at 2nd flloor. -rated wall:seal all ridge penetrations at firewalls 2130 2136 - tie rafters to ceiling josit with 3 nails. -braced wall straping needs to beinstalled cornctly, not loose.
Rated Assembly Inspection Failed 3/22/2017 03/22/2017
Erosion Control Inspection Residential Partial 03/22/2017
All Rough Inspection - Residential Failed 3/23/2017 (8:00 to 5:00) 3/23/2017 03/23/2017
Misc
Corrective Action Required
03/21/2017
-braced wall straping needs to beinstalled cornctly, not loose. 2130 east unit 2nd floor -2136 seal ridge from unit east.
Rated Assembly Inspection Passed 3/23/2017 (8:00 to 5:00) 3/23/2017 03/23/2017
Erosion Control Inspection Residential Partial 03/23/2017
All Rough Inspection - Residential Not Ready 3/24/2017 (8:00 to 5:00) 3/24/2017 03/24/2017
Misc
Corrective Action Required
03/23/2017
-braced wall straping needs to beinstalled cornectly, not loose. 2130 east unit 2nd floor -2136 seal ridge from unit east. units locked at 8:30am all trash needs to be picked up at rear of lots, north tree line asap. recall ok to insulate
All Rough Inspection - Residential Not Ready 3/27/2017 (8:00 to 5:00) 3/27/2017 03/27/2017
Misc
Corrective Action Required
03/24/2017
-braced wall straping needs to beinstalled correctly, not loose. 2130 east unit 2nd floor -2136 seal ridge from unit east. units locked at 8:30am all trash needs to be picked up at rear of lots, north tree line asap. recall ok to insulate DENIED DUE TO TRASH AND DEBRIS
All Rough Inspection - Residential Passed 3/28/2017 (8:00 to 5:00) 3/28/2017 03/28/2017
Misc
Resolved
03/28/2017
-braced wall straping needs to beinstalled correctly, not loose. 2130 east unit 2nd floor -2136 seal ridge from unit east. units locked at 8:30am all trash needs to be picked up at rear of lots, north tree line asap. recall ok to insulate DENIED DUE TO TRASH AND DEBRIS
Driveway Inspection Passed 3/31/2017 3/31/2017 04/10/2017
Occupancy Inspection - Codes Residential Failed 4/24/2017 04/24/2017
Misc
Corrective Action Required
04/24/2017
- SOD, EROSION CONTROL, GUTTERS, - WATER METER PITS NEED TO BE FLUSH WITH GRADE AND FIXED. - SEAL GARAGE FROM DWELLINGS AT BOX OUTS AND EDGE OF FURNACE DOOR.
Occupancy Inspection - Codes Residential Temporary C of O 4/25/2017 04/25/2017
Misc
Corrective Action Required
04/24/2017
- SOD, EROSION CONTROL, GUTTERS, - WATER METER PITS NEED TO BE FLUSH WITH GRADE AND FIXED.
Occupancy Inspection - Codes Residential Failed 7/14/2017 7/14/2017 07/13/2017
Misc
Corrective Action Required
04/25/2017
- SOD, EROSION CONTROL, GUTTERS, - WATER METER PITS NEED TO BE FLUSH WITH GRADE AND FIXED. needs sod on east side
Occupancy Inspection - Codes Residential Full C of O 1/19/2018 1/19/2018 01/19/2018
Misc
Resolved
01/19/2018
- SOD, EROSION CONTROL, GUTTERS, - WATER METER PITS NEED TO BE FLUSH WITH GRADE AND FIXED. needs sod on east side
Documents & Images
Date Uploaded File Type Document Name
11/29/2016 Receipt Receipt for transaction: 2016-006981
11/29/2016 Letter Codes Building Permit
12/28/2016 Letter Inspection Summary
01/25/2017 Letter Inspection Summary
01/27/2017 Letter Inspection Summary
02/01/2017 Letter Inspection Summary
02/02/2017 Letter Inspection Summary
03/21/2017 Letter Inspection Summary
03/22/2017 Letter Inspection Summary
03/23/2017 Letter Inspection Summary
03/24/2017 Letter Inspection Summary
03/27/2017 Letter Inspection Summary
03/28/2017 Letter Inspection Summary
04/24/2017 Letter Inspection Summary
04/25/2017 Letter Codes Temporary Certificate of Occupancy
07/13/2017 Letter Inspection Summary
01/19/2018 Letter Field Certificate of Occupancy
01/22/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home