Permit Application Status

PRRES20162935


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162935
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK
11/10/2016
11/18/2016
07/21/2017
Locations
Contacts
CAPITAL CONSTRUCTION SERVICES LLC, Address:2642 NE HAGAN RD, Phone:(816) 875-0018  
SDI ELECTRIC, LLC, Address:3317 W 81ST ST, Phone:(913) 636-5021  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 11/14/2016 11/18/2016
Jonathon Hilton
Plot Plan Review Approved 11/18/2016
Jonathon Smith
Plot Plan Review Rejected 11/14/2016 11/17/2016
Jonathon Smith
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $811.44 $811.44 Paid 11/18/2016
8331507-Sewer Connection Fee $360.00 $360.00 Paid 11/18/2016
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 11/18/2016
8350015-Water Meter Fee $405.36 $405.36 Paid 11/18/2016
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 11/18/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/18/2016 (10:15) 11/18/2016 11/18/2016
Underslab Plumbing Inspection - Residential Passed 12/6/2016 12/6/2016 12/06/2016
Piers/Caissons Inspection - Residential Passed 2/2/2017 (8:00) 2/2/2017 02/02/2017
Water Service Inspection - R Passed 2/9/2017 02/09/2017
Sewer Service Inspection - R Passed 2/9/2017 (2:30) 2/9/2017 02/09/2017
Gas Service Inspection - Residential Passed 2/22/2017 02/22/2017
Electrical Service Inspection Passed 2/22/2017 02/22/2017
All Rough Inspection - Residential Failed 2/22/2017 2/22/2017 02/22/2017
Misc
Corrective Action Required
02/22/2017
FRAMING: -INSTALL SECURITY BLOCKING PER LS CODE AT GARAGE DOOR; FILL IN GAPS AT HINGES WITH WOOD -MORE NAILING OF H-FRAME INTO LVL -STRAP ALL TOP PLATES LAPPED LESS THAN 24" IN GARAGE -FIREBLOCK FUR-OUT LAUNDRY WALL -INSTALL DOUBLE LVL BEAM PER PLAN ABOVE FURNACE -FIREBLOCK BASEMENT BED CLOSET WALLS FROM CEILING SPACE MECHANICAL: -PAN OFF STUD RETURN AIR SPACE FROM THE REST OF TRIANGULAR SPACE PLUMBING: -PROTECT PVC AT LAUNDRY AND PANTRY -INSTALL STUD SHOE FOR OVER BORED STUD AT BASEMENT BATH ***OK TO INSULATE
All Rough Inspection - Residential Partial 2/27/2017 2/27/2017 02/27/2017
Misc
Corrective Action Required
02/22/2017
-INSTALL DOUBLE LVL BEAM PER PLAN ABOVE FURNACE ***OK TO INSULATE
Driveway Inspection Partial 3/17/2017 3/17/2017 03/23/2017
PW-Misc
Informational
03/23/2017
The driveway was formed and rock was compacted on 3/17/17Steve Robbins 03/23/2017 3:02 PM
Driveway Inspection Passed 3/23/2017 03/23/2017
PW-Misc
Informational
03/23/2017
The driveway was formed and rock was compacted on 3/17/17Steve Robbins 03/23/2017 3:02 PM
PW-Misc
Informational
03/23/2017
The driveway was poured and has passed inspection.Steve Robbins 03/23/2017 3:04 PM
Sidewalk Inspection Partial 3/17/2017 3/17/2017 03/23/2017
PW-Misc
Informational
03/23/2017
The sidewalk was formed and the rock was compacted, this also had an ADA ramp and its was formed and rock compacted with pins.Steve Robbins 03/23/2017 3:08 PM
Sidewalk Inspection Failed 3/23/2017 03/23/2017
PW-Misc
Informational
03/23/2017
The sidewalk was formed and the rock was compacted, this also had an ADA ramp and its was formed and rock compacted with pins.Steve Robbins 03/23/2017 3:08 PM
PW-Misc
Informational
03/23/2017
The sidewalk passed the inspection but the ADA did not. They need to re-do the landing and 4 sections of sidewalk leading up to and including the turn-around area. I talked with Bob Leo today and he will let me know when he is going to do it over.Steve Robbins 03/23/2017 3:12 PM
Sidewalk Inspection Partial 4/13/2017 04/13/2017
PW-Misc
Informational
03/23/2017
The sidewalk was formed and the rock was compacted, this also had an ADA ramp and its was formed and rock compacted with pins.Steve Robbins 03/23/2017 3:08 PM
PW-Misc
Informational
03/23/2017
The sidewalk passed the inspection but the ADA did not. They need to re-do the landing and 4 sections of sidewalk leading up to and including the turn-around area. I talked with Bob Leo today and he will let me know when he is going to do it over.Steve Robbins 03/23/2017 3:12 PM
Corrective Action Required
04/13/2017
PW-Misc
Informational
04/13/2017
This morning I inspected the forms after they did their tear-out. The forms passed inspection.Steve Robbins 04/13/2017 3:30 PM
Sidewalk Inspection Passed 4/14/2017 04/14/2017
PW-Misc
Informational
04/13/2017
The sidewalk was formed and the rock was compacted, this also had an ADA ramp and its was formed and rock compacted with pins.Steve Robbins 03/23/2017 3:08 PM
PW-Misc
Informational
04/13/2017
The sidewalk passed the inspection but the ADA did not. They need to re-do the landing and 4 sections of sidewalk leading up to and including the turn-around area. I talked with Bob Leo today and he will let me know when he is going to do it over.Steve Robbins 03/23/2017 3:12 PM
PW-Misc
Informational
04/14/2017
They tore out the sections that failed for the ada ramp and formed them again and the forms passed. I went back today to check and it passed this time.Steve Robbins 04/14/2017 3:49 PM
All Rough Inspection - Residential Passed 05/19/2017
Misc
Resolved
05/19/2017
-INSTALL DOUBLE LVL BEAM PER PLAN ABOVE FURNACE ***OK TO INSULATE
Occupancy Inspection - Codes Residential Failed 5/19/2017 5/19/2017 05/19/2017
Misc
Corrective Action Required
05/19/2017
****STREET SHALL BE CLEANED AND EROSION CONTROL INSTALLED ALONG THE STREET -OBTAIN LAWN IRRIGATION PERMIT -BRING WATER METER TO FINAL GRADE -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR WALL PENETRATIONS, ABOVE METER, AC DISCONNECTS, ETC -INSTALL FRONT STOOP LIGHT -DECK: INSTALL HANDRAIL NO WIDER THAN 3.5"; CLOSE OPENINGS BETWEEN TREADS TO 4" OR LESS; INSTALL DOUBLE DECK BEAM AND ATTACH TO EACH POST WITH TWO 1/2" THROUGH BOLTS -FB WALL PENETRATION UNDER GARAGE SINK -OPEN CANLIGHT NOT ALLOWED INSIDE MASTER CLOSET -FLOOR RECEPTACLE BOXES TO FLUSH WITH FLOOR FINISH OR INSTALL SPARK RINGS -PROVIDE COMBUSTION AIR OPENINGS PER CODE -LOCATE AND MAKE ACCESSIBLE SEWER CLEANOUT
Occupancy Inspection - Codes Residential Temporary C of O 5/24/2017 5/24/2017 05/24/2017
Misc
Corrective Action Required
05/19/2017
****STREET SHALL BE CLEANED AND EROSION CONTROL INSTALLED ALONG THE STREET -OBTAIN LAWN IRRIGATION PERMIT -BRING WATER METER TO FINAL GRADE -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR WALL PENETRATIONS, ABOVE METER, AC DISCONNECTS, ETC -DECK: INSTALL HANDRAIL NO WIDER THAN 3.5"; CLOSE OPENINGS BETWEEN TREADS TO 4" OR LESS; INSTALL DOUBLE DECK BEAM AND ATTACH TO EACH POST WITH TWO 1/2" THROUGH BOLTS
Occupancy Inspection - Codes Residential Failed 6/30/2017 06/30/2017
Misc
Corrective Action Required
05/24/2017
****STREET SHALL BE CLEANED -DECK: INSTALL HANDRAIL NO WIDER THAN 3.5". **INSTALL GRASPABLE HANDRAIL
Occupancy Inspection - Codes Residential Full C of O 07/21/2017
Misc
Resolved
07/21/2017
****STREET SHALL BE CLEANED -DECK: INSTALL HANDRAIL NO WIDER THAN 3.5". **INSTALL GRASPABLE HANDRAIL
Documents & Images
Date Uploaded File Type Document Name
11/18/2016 Receipt Receipt for transaction: 2016-006876
11/18/2016 Letter Codes Building Permit
11/18/2016 Plot Plan DOC111816-003
11/18/2016 Letter Inspection Summary
12/06/2016 Letter Inspection Summary
02/02/2017 Letter Inspection Summary
02/09/2017 Letter Inspection Summary
02/22/2017 Letter Inspection Summary
02/27/2017 Letter Inspection Summary
03/23/2017 Letter PW-Daily Inspection Summary
03/23/2017 Letter PW-Daily Inspection Summary
03/23/2017 Letter PW-Daily Inspection Summary
03/23/2017 Letter PW-Daily Inspection Summary
03/23/2017 Letter PW-Daily Inspection Summary
04/13/2017 Letter PW-Daily Inspection Summary
04/14/2017 Letter PW-Daily Inspection Summary
05/19/2017 Letter Inspection Summary
05/24/2017 Letter Codes Temporary Certificate of Occupancy
06/30/2017 Letter Inspection Summary
07/21/2017 Letter Field Certificate of Occupancy
07/24/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home