Permit Application Status

PRRES20162559


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162559
Building Permit - Residential
Certificate of Occupancy
MCGRAW HOMES INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY
10/05/2016
10/11/2016
05/18/2017
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 10/07/2016 10/06/2016
Hector Soto Jr.
Plot Plan Review Approved 10/07/2016 10/06/2016
James Fletchall
Residential Plan Review Rejected 10/07/2016 10/06/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,188.80 $1,188.80 Paid 10/11/2016
8331507-Sewer Connection Fee $630.00 $630.00 Paid 10/11/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/11/2016
Water Meter Fee $405.36 $405.36 Paid 10/11/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/11/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 10/13/2016 (4:30) 10/13/2016 10/13/2016
Misc
Corrective Action Required
10/13/2016
-HAVE ENGINEER CHECK THE SOIL FOR BEARING CAPACITY
Foundation Inspection - Residential Failed 10/28/2016 (3:30) 10/28/2016 10/28/2016
Misc
Corrective Action Required
10/28/2016
-INSTALL VERTICAL REBAR EVERY 12" PER PLAN. SHORT REBARS MUST BE EXTENDED TO TOP OF WALL
Underslab Plumbing Inspection - Residential Passed 11/14/2016 11/14/2016
Suspended Slab Inspection Passed 12/29/2016 (3:00) 12/29/2016 12/29/2016
Sewer Service Inspection - R Failed 1/12/2017 (8:45) 1/12/2017 01/12/2017
Misc
Corrective Action Required
01/12/2017
CANNOT USE WIRE NUT FOR TRACER WIRE SPLICE
Sewer Service Inspection - R Passed 1/13/2017 (8:00) 1/13/2017 01/13/2017
Misc
Resolved
01/13/2017
CANNOT USE WIRE NUT FOR TRACER WIRE SPLICE
Water Service Inspection - R Partial 1/13/2017 01/13/2017
Water Service Inspection - R Passed 1/17/2017 01/17/2017
Electrical Service Inspection Passed 1/31/2017 1/31/2017 01/31/2017
Gas Service Inspection - Residential Passed 1/31/2017 1/31/2017 01/31/2017
All Rough Inspection - Residential Failed 1/31/2017 1/31/2017 01/31/2017
Misc
Corrective Action Required
01/31/2017
FRAMING: -GARAGE PORTAL BRACE WALLS-NAIL THE SHEATHING TO DOUBLE STUDS ON EACH SIDE OF WALL WITH 8D@3' OC -ANCHOR GARAGE AND BASEMENT SILL PLATE PER CODE. MAKE SURE TO HAVE MIN. 2 ANCHORS FOR EACH SHORT PLATE -SUPPORT HIPS ABOVE GARAGE -NAIL THE CORNER STUDS AT BED/GARAGE WALL INTERSECTION -HAVE ENGINEER OK THE SPLICED RAFTERS ABOVE GARAGE/FOYER -INSTALL HANGERS FOR CEILING JOIST-LVL CONNECTIONS ABOVE KITCHEN -DECK DOOR-INSTALL SECURITY BLOCKING PER LS SECURITY CODE -BRACE THE 18" LVL BEAM ENDS FROM ROTATION -SUPPORT THE LVL HIP TO MASTER BED CEILING BEAM -THE HALLWAY WALL OUTSIDE MASTER BED AND SUNROOM WALL ARE NOT BEARING WALLS -PROVIDE SOLIDBLOCKING UNDER 18" LVL POINT LOAD (BELOW MUD SINK) -TOE NAIL ALL JOISTS TO TOP PLATES AND SILL WITH 3-8D NAILS -EXPOSE DECK FIREPLACE SPACE -3 STUD SUPPORT FOR LVL AT MASTER CLOSET PLUMBING: -PROTECT PVC AT BASEMENT BATH UNDER STAIR ELECTRICAL: -BOND THE HYDROTUB MOTOR TO THE METAL VALVE ASSY -MAKE SURE TO PROVIDE ACCESS TO UFER AT FINAL. MECHANICAL: -PROVIDE MIN 1" CLEARANCE AROUND B-VENT IN CHASE -PROVIDE COMBUSTION AIR OPENINGS PER CODE FOR MECH. RM -VENT BASEMENT BATH FAN **DO NOT INSULATE
All Rough Inspection - Residential Failed 2/2/2017 2/2/2017 02/02/2017
Misc
Corrective Action Required
01/31/2017
FRAMING: -THE SUNROOM WALL ARE NOT BEARING WALLS **YOU CAN HAVE THE ENGINEER OK THIS -PROVIDE SOLIDBLOCKING UNDER 18" LVL POINT LOAD (BELOW MUD SINK) **I NEED THE LADDER TO INSPECT. DO THE FOLLOWINGS: REPAIR THE TORN FLEX DUCT; MAKE SURE THE BLOCKING GO TO I BEAM; MAKE SURE THE WIRING IS NOT SANDWICHED IN BETWEEN THE LUMBERS MECHANICAL: -PROVIDE COMBUSTION AIR OPENINGS PER CODE FOR MECH. RM **THE FURNACE (66K BTU) AND WATER HEATER (40K BTU) REQUIRE EACH OPENING TO HAVE MIN. 106 SQUARE INCHES OF CLEAR OPENING OR 1.33 X 106 WHEN THE GRILL IS INSTALLED **OK TO INSULATE
All Rough Inspection - Residential Passed 2/3/2017 2/3/2017 02/03/2017
Misc
Resolved
02/03/2017
-PROVIDE SOLIDBLOCKING UNDER 18" LVL POINT LOAD (BELOW MUD SINK) **I NEED THE LADDER TO INSPECT. DO THE FOLLOWINGS: REPAIR THE TORN FLEX DUCT; MAKE SURE THE BLOCKING GO TO I BEAM; MAKE SURE THE WIRING IS NOT SANDWICHED IN BETWEEN THE LUMBERS **OK TO ROCK
Footing Inspection - Residential Passed 02/03/2017
Misc
Resolved
02/03/2017
-HAVE ENGINEER CHECK THE SOIL FOR BEARING CAPACITY
Foundation Inspection - Residential Passed 02/03/2017
Misc
Resolved
02/03/2017
-INSTALL VERTICAL REBAR EVERY 12" PER PLAN. SHORT REBARS MUST BE EXTENDED TO TOP OF WALL
Piers/Caissons Inspection - Residential Passed 3/7/2017 (2:30) 3/7/2017 03/07/2017
Suspended Slab Inspection Passed 3/21/2017 (11:15) 3/21/2017 03/21/2017
Driveway Inspection Passed 4/20/2017 4/20/2017 04/21/2017
Occupancy Inspection - Codes Residential Failed 5/15/2017 5/15/2017 05/15/2017
Misc
Corrective Action Required
05/15/2017
-OBTAIN LAWN IRRIGATION PERMIT -FINAL GRADE, SOD, SPLASHBLOCKS -EXPOSE SEWER TRACER BOX -COVER&SEAL WALL AT DECK BEAM SUPPORT END; BLOCK; BLOCK DECK POST -INSTALL BEDROOM WINDOW CRANKS -FOR THE SMALLER AC UNIT, INSTALL MAX. 30 AMP BREAKER -INSTALL A RECEPTACLE IN UNFINISHED PORTION OF THE BASEMENT UNDER STOOP -PROVIDE ACCESS TO SEWER CLEANOUT AND UFER GROUNDING CONNECTION -HANDRAIL SHALL BE CONTINUOUS FROM TOP RISER TO BOTTOM RISER AND HAVE MIN. 1.5" CLEARANCE -GARAGE DOOR TO BE SELF-CLOSING -PROVIDE CLEAR 12"X12" ACCESSWAY TO THE HYDROTUB MOTOR; RECEPTCLE TO FACE TOWARD FRONT
Occupancy Inspection - Codes Residential Failed 5/17/2017 5/17/2017 05/17/2017
Misc
Corrective Action Required
05/15/2017
-GARAGE DOOR TO BE SELF-CLOSING
Occupancy Inspection - Codes Residential Full C of O 5/18/2017 5/18/2017 05/18/2017
Misc
Resolved
05/18/2017
-GARAGE DOOR TO BE SELF-CLOSING
Documents & Images
Date Uploaded File Type Document Name
10/11/2016 Receipt Receipt for transaction: 2016-006349
10/11/2016 Letter Codes Building Permit
10/11/2016 Plot Plan DOC101116-031
10/13/2016 Letter Inspection Summary
10/28/2016 Letter Inspection Summary
11/02/2016 SOIL INSPECTION SUMMARY
11/03/2016 Engineer Report/Study DOC110316-014
11/14/2016 Letter Inspection Summary
12/29/2016 Letter Inspection Summary
01/12/2017 Letter Inspection Summary
01/13/2017 Letter Inspection Summary
01/17/2017 Letter Inspection Summary
01/31/2017 Letter Inspection Summary
02/02/2017 Letter Inspection Summary
02/03/2017 Letter Inspection Summary
03/07/2017 Letter Inspection Summary
03/21/2017 Letter Inspection Summary
04/21/2017 Letter Inspection Summary
05/15/2017 Letter Inspection Summary
05/17/2017 Letter Inspection Summary
05/18/2017 Letter Field Certificate of Occupancy
05/19/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home