Permit Application Status

PRRES20162545


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162545
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK UNFINISHED BASEMENT
10/05/2016
10/17/2016
04/26/2017
Locations
Contacts
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
SDI ELECTRIC, LLC, Address:3317 W 81ST ST, Phone:(913) 636-5021  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 10/10/2016 10/17/2016
Development Center
Plot Plan Review Approved 10/13/2016
James Fletchall
Plot Plan Review Rejected 10/07/2016 10/06/2016
James Fletchall
Plot Plan Review (P&D) Rejected 10/07/2016 10/06/2016
Hector Soto Jr.
DE Corps of Engineers
Corrective Action Required
10/06/2016

The deck shapes shown on the lot drawing and the inset drawing do not match.
Residential Plan Review Approved 10/07/2016 10/05/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,055.97 $1,055.97 Paid 10/17/2016
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/17/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/17/2016
Water Meter Fee $405.36 $405.36 Paid 10/17/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/17/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/24/2016 (4:00) 10/24/2016 10/24/2016
Sewer Service Inspection - R Passed 11/1/2016 (1:00) 11/1/2016 11/01/2016
Water Service Inspection - R Passed 11/1/2016 (1:00) 11/1/2016 11/01/2016
Underslab Plumbing Inspection - Residential Passed 11/2/2016 11/2/2016 11/02/2016
Piers/Caissons Inspection - Residential Passed 11/10/2016 (1:30) 11/10/2016 11/10/2016
Electrical Service Inspection Passed 1/25/2017 1/25/2017 01/25/2017
Gas Service Inspection - Residential Passed 1/25/2017 1/25/2017 01/25/2017
All Rough Inspection - Residential Failed 1/25/2017 1/25/2017 01/25/2017
Misc
Corrective Action Required
01/25/2017
FRAMING: -TOE NAIL ALL JOISTS TO WALL TOP PLATES WITH 3-8D NAILS THROUGHOUT HOUSE -INSTALL ROOF FLASHING FOR VENT -INSTALL COLLAR TIES PER CODE THROUGHOUT -ANCHOR GARAGE SILL PLATE WITHIN 12" OF END -NAIL CORNER STUDS WITH 16D @ 12" OC OR EQUIVALENT NAILING -FIREBLOCK GARAGE DUCT CHASE FROM JOIST SPACE -PROTECT GARAGE I BEAM -INSTALL DOUBLE JOIST EVERY OTHER UNDER FRONT BED PER PLAN -NAIL FRONT BED CORNER STUDS -BLOCK BASEMENT DOOR PER SECURITY CODE -COMPLETE FURDOWN OF PANTRY CEILING AND FIREBLOCK AS REQUIRED PLUMBING: -INSULATE ALL PLUMBING AT EXTERIOR WALL. HOW ARE YOU GOING TO INSULATE THE DRAINAGE LINES, ESPECIALLY THE 3" PIPE? -FYI:THE 3" PIPE IS BULGING OUT OF WALL AT FOYER. -AT ALL EXTERIOR AND INTERIOR BEARING WALL WHERE WALL TOP PLATES ARE BORED MORE THAN 50%, SHALL INSTALL STRUCTURAL STRAPS AND NAIL ALL STARP NAIL HOLES -PROTECT WATER LINES ABOVE FIREPLACE -INSTALL STUD SHOE AT HALF BATH AND LAUNDRY WALL MECHANICAL: -VENT ALL BATH FANS ELECTRICAL: -PROTECT WIRING UNDER MIDDLE WINDOW OF LIVING RM **OK TO INSULATE
All Rough Inspection - Residential Failed 1/30/2017 1/30/2017 01/30/2017
Misc
Corrective Action Required
01/25/2017
-AT ALL EXTERIOR AND INTERIOR BEARING WALL WHERE WALL TOP PLATES ARE BORED MORE THAN 50%, SHALL INSTALL STRUCTURAL STRAPS AND NAIL ALL STARP NAIL HOLES **OK TO INSULATE
All Rough Inspection - Residential Passed 1/31/2017 1/31/2017 01/31/2017
Misc
Resolved
01/31/2017
-AT ALL EXTERIOR AND INTERIOR BEARING WALL WHERE WALL TOP PLATES ARE BORED MORE THAN 50%, SHALL INSTALL STRUCTURAL STRAPS AND NAIL ALL STARP NAIL HOLES **OK TO INSULATE
Driveway Inspection Partial 3/15/2017 3/15/2017 03/15/2017
PW-Misc
Informational
03/15/2017
They were too close to the property line. so I asked them to move it over so it will be a foot away. I also asked them to tear out a section of curb and replace with granite mix.Steve Robbins 03/15/2017 4:00 PM
Driveway Inspection Passed 3/17/2017 03/17/2017
PW-Misc
Informational
03/15/2017
They were too close to the property line. so I asked them to move it over so it will be a foot away. I also asked them to tear out a section of curb and replace with granite mix.Steve Robbins 03/15/2017 4:00 PM
PW-Misc
Informational
03/17/2017
The curb has been replaced and the approach has been poured.Steve Robbins 03/17/2017 4:32 PM
Occupancy Inspection - Codes Residential Failed 4/13/2017 4/13/2017 04/13/2017
Misc
Corrective Action Required
04/13/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -EXPOSE AND BRING TO FINAL GRADE THE WATER METER -SEWER TRACER BOX -SEAL EXTERIOR: EXT. WALL PENETRATIONS, LIGHTS, ABOVE METER AND AC DISCONNECT -INSTALL SUMP PUMP BACKUP BATTERY -BLOCK BASEMENT DOOR STUD PER SECURITY CODE; INSTALL 4-3' SCREWS AT STRIKE PLATE -OPEN CEILING ELECTRICAL BOX NEAR FURNACE -NO POWER TO BASEMENT LIGHTS AND RECEPTACLES -DECK EXTERIOR DOOR: INSTALL 4-3' SCREWS AT STRIKE PLATE -INSTALL WATER HAMMERING ARRESTORS FOR DISH WASHER AND CLOTHES WASHER -INSTALL FACE PLATE FOR THE RECEPTACLE INSIDE THE MUD CLOSET -FIREBLOCK THE BASEMENT FROM GARAGE AT BEAM POCKET -THE FRONT NORTH BED SMOKE ALARM NOT INTERCONNECTED -INSTALL BEDROOM WINDOW CRANKS
Occupancy Inspection - Codes Residential Temporary C of O 4/24/2017 4/24/2017 04/24/2017
Misc
Corrective Action Required
04/13/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -BLOCK BASEMENT DOOR STUD PER SECURITY CODE **BLOCK AT STRIKE PLATE HEIGHT TO COLUMN, THEN COUNTER-BLOCK ON THE OTHER SIDE OF COLUMN -DECK DOOR-INSTALL 4-3" SCREWS AT STRIKE PLATE
Occupancy Inspection - Codes Residential Full C of O 4/26/2017 4/26/2017 04/26/2017
Misc
Resolved
04/26/2017
-FINAL GRADE, SOD, SPLASHBLOCKS -BLOCK BASEMENT DOOR STUD PER SECURITY CODE **BLOCK AT STRIKE PLATE HEIGHT TO COLUMN, THEN COUNTER-BLOCK ON THE OTHER SIDE OF COLUMN -DECK DOOR-INSTALL 4-3" SCREWS AT STRIKE PLATE
Documents & Images
Date Uploaded File Type Document Name
10/17/2016 Receipt Receipt for transaction: 2016-006406
10/17/2016 Letter Codes Building Permit
10/17/2016 Plot Plan DOC101716-003
10/24/2016 Letter Inspection Summary
11/01/2016 Letter Inspection Summary
11/02/2016 Letter Inspection Summary
11/10/2016 Letter Inspection Summary
01/25/2017 Letter Inspection Summary
01/30/2017 Letter Inspection Summary
01/31/2017 Letter Inspection Summary
03/15/2017 Letter PW-Daily Inspection Summary
03/17/2017 Letter PW-Daily Inspection Summary
04/13/2017 Letter Inspection Summary
04/24/2017 Letter Codes Temporary Certificate of Occupancy
04/26/2017 Letter Field Certificate of Occupancy
04/27/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents