Permit Application Status

PRRES20162317


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162317
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK
09/12/2016
09/19/2016
09/28/2017
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 219119  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
SDI ELECTRIC, LLC, Address:3317 W 81ST ST, Phone:(913) 636-5021  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/15/2016
James Fletchall
Plot Plan Review Rejected 09/14/2016 09/13/2016
James Fletchall
Plot Plan Review (P&D) Approved 09/14/2016 09/12/2016
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,135.75 $1,135.75 Paid 09/21/2016
8331507-Sewer Connection Fee $600.00 $600.00 Paid 09/21/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 09/21/2016
Water Meter Fee $405.36 $405.36 Paid 09/21/2016
Right of Way Permit Fee $75.00 $75.00 Paid 09/21/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Partial 9/22/2016 (1:00) 9/22/2016 09/22/2016
Misc
Corrective Action Required
09/22/2016
-TWO GARAGE PADS ARE AT EDGE OF OVERDIG AND ARE UNDERMINED. FILL THE OVERDIG WITH CLEAN GRAVEL AND HAVE THIS INSPECTED
Sewer Service Inspection - R Passed 10/5/2016 (9:30) 10/5/2016 10/05/2016
Water Service Inspection - R Partial 10/5/2016 10/05/2016
Underslab Plumbing Inspection - Residential Passed 10/6/2016 10/6/2016 10/05/2016
Water Service Inspection - R Passed 10/5/2016 (1:00) 10/5/2016 10/05/2016
Piers/Caissons Inspection - Residential Passed 10/10/2016 (8:00) 10/10/2016 10/10/2016
Footing Inspection - Residential Passed 10/10/2016 10/10/2016
Misc
Resolved
10/10/2016
-TWO GARAGE PADS ARE AT EDGE OF OVERDIG AND ARE UNDERMINED. FILL THE OVERDIG WITH CLEAN GRAVEL AND HAVE THIS INSPECTED
All Rough Inspection - Residential Failed 12/22/2016 12/22/2016 12/22/2016
Misc
Corrective Action Required
12/22/2016
***INSTALL EROSION CONTROL ALONG THE STREET FRAMING: -SUPPORT HIP ABOVE FRONT DINING; HIP ABOVE MASTER BEDHIPS AND VALLEY ABOVE GARAGE -INSTALL 3 STUD SUPPORT FOR 3X JOIST AND SOLIDBLOCK TO I BEAM BELOW (AT FRONT DINING) -OVERNOTCHED JOIST ABOVE MASTER CLOSET/LAUNDRY -INSTALL HANGERS FOR JOIST CONNECTIONS TO BEAM ABOVE MASTER BATH -FIREBLOCK FIREPLACE SPACE FROM ROOF SPACE -FULLY NAIL ANGLE HANGER ABOVE GREATROOM -INSTALL SIX STUDS NAILED TOGETHER FOR I BEAM SUPPORT AT KITCHEN END -PROVIDE R-13 FOR WALL AND R-19 FOR CEILING IN GARAGE -SEAL RETURN AIR SPACE PENETRATIONS AT CEILING -INSTALL DOUBLE LVL BEAM UNDER LOFT BEARING WALL -SUPPORT HIPS ABOVE 2ND FL WEST BED TO BEARING WALL -BRACE ROOF SUPPORT LVL BEAM ENDS FROM ROTATION PLUMBING: -INSTALL STUD SHOE FOR OVER BORED STUD AT MASTER CLOSET/LAUNDRY WALL -PROTECT WATER LINES AT MASTER CLOSET WALL AND AT MASTER SHOWER -STRAP TOP PLATES BORED > 50% AT REAR DINING -INSULATE WATER LINES AT REAR DINING -INSTALL ROOF FLASHING FOR VENT ELECTRICAL: -BOND HYDROTUB MOTOR TO THE WATER METAL VALVE ASSY FOR EQUIPOTENTIAL -PROTECT WIRINGS AT KITCHEN WALL NEAR 3" PVC MECHANICAL: -COMPLETE FLUE FOR FIREPLACE **OK TO INSULATE
Gas Service Inspection - Residential Failed 12/22/2016 12/22/2016 12/22/2016
Misc
Corrective Action Required
12/22/2016
NO PRESSURE
Electrical Service Inspection Passed 12/22/2016 12/22/2016 12/22/2016
Gas Service Inspection - Residential Passed 12/30/2016 12/30/2016 12/30/2016
Misc
Resolved
12/30/2016
NO PRESSURE
All Rough Inspection - Residential Failed 12/30/2016 12/30/2016 12/30/2016
Misc
Corrective Action Required
12/22/2016
***INSTALL EROSION CONTROL ALONG THE STREET. NO FURTHER INSPECTION IF EROSION CONTROL IS NOT RESTORED -SUPPORT HIPS AND VALLEY ABOVE GARAGE -OVERNOTCHED JOIST ABOVE MASTER CLOSET/LAUNDRY **FIX IS NON-COMPLIANT: 1) NEED DOUBLE TRIMMER JOIST WHEN FRAME OPENING IS MORE THAN 3 FT FROM SUPPORT. 2) TAIL JOIST IS NOT SUPPORTED TO THE HEADER JOIST. 3) YOU'RE BLOCKING THE COLD AIR RETURN -SEAL RETURN AIR SPACE PENETRATIONS AT CEILING **ABOVE KITCHEN **OK TO INSULATE
All Rough Inspection - Residential Failed 1/6/2017 01/06/2017
Misc
Corrective Action Required
12/30/2016
-OVERNOTCHED JOIST ABOVE MASTER CLOSET/LAUNDRY **FIX IS NON-COMPLIANT: EVERY TIME I ASKED THE FRAMER TO FIX THING, HE MADE IT WORSE. JUST ADD A 2X4 TO SUPPORT THE SUBFLOOR UNDER THE SHOWER. SUBFLOOR IS ONLY RATED FOR 24" MAX. SPAN **OK TO ROCK OTHER AREA, EXCEPT AT THE LOCATION ABOVE
Driveway Inspection Passed 1/24/2017 01/24/2017
Sidewalk Inspection Passed 1/24/2017 01/24/2017
Occupancy Inspection - Codes Residential Failed 6/12/2017 6/12/2017 06/12/2017
Misc
Corrective Action Required
06/12/2017
-UN-RESOLVED ISSUE FROM ALL ROUGH INSPECTION OVER MASTER SHOWER. EXPOSE FOR INSPECTION. -SUBMIT AS-GRADED PLOT PLAN FOR APPROVAL FROM ENGINEERING. -INSTALL SECOND LOCK AT REAR SLIDER -REPAIR IRRIGATION LEAK IN BASEMENT AT BACKFLOW PREVENTOR -INSTALL REAR STEPS -INSTALL COVER FOR REAR RECEPTACLE
Occupancy Inspection - Codes Residential Temporary C of O 9/21/2017 9/21/2017 at 9:25 AM 09/21/2017
Misc
Corrective Action Required
06/12/2017
-UN-RESOLVED ISSUE FROM ALL ROUGH INSPECTION OVER MASTER SHOWER. EXPOSE FOR INSPECTION. **REQUIRE VERIFICATION THAT THE SUBFLOOR SUPPORT UNDER THE SHOWER IS COMPLETED
All Rough Inspection - Residential Passed 09/28/2017
Misc
Resolved
09/28/2017
Occupancy Inspection - Codes Residential Full C of O 09/28/2017
Misc
Resolved
09/28/2017
-UN-RESOLVED ISSUE FROM ALL ROUGH INSPECTION OVER MASTER SHOWER. EXPOSE FOR INSPECTION. **REQUIRE VERIFICATION THAT THE SUBFLOOR SUPPORT UNDER THE SHOWER IS COMPLETED
Documents & Images
Date Uploaded File Type Document Name
09/19/2016 Receipt Receipt for transaction: 2016-006002
09/19/2016 Letter Codes Building Permit
09/19/2016 Plot Plan DOC091916-001
09/21/2016 Receipt Receipt for transaction: 2016-006044
09/22/2016 Letter Inspection Summary
10/05/2016 Letter Inspection Summary
10/05/2016 Letter Inspection Summary
10/10/2016 Letter Inspection Summary
12/22/2016 Letter Inspection Summary
12/30/2016 Letter Inspection Summary
01/06/2017 Letter Inspection Summary
01/24/2017 Letter Inspection Summary
06/12/2017 Letter Inspection Summary
09/06/2017 Plot Plan As Graded Plot Plan 20162317
09/21/2017 Letter Codes Temporary Certificate of Occupancy
09/28/2017 Letter Field Certificate of Occupancy
09/29/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home