Permit Application Status

PRRES20130710


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20130710
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
HOUSE WITH COVERED PATIO
04/22/2013
05/02/2013
04/21/2014
Locations
Contacts
WYSS HOME BUILDING LLC, Address:PO BOX 6620, Phone:(816) 820-0142  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
ROBERTSON PLUMBING LLC, Address:PO BOX 165, Phone:(816) 781-9340  
ACH DEVELOPMENT LLC, Address:3170 NE CARNEIGE # 400  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 04/24/2013 04/29/2013
Codes Admin
Plot Plan Review Approved 04/24/2013 04/24/2013
Gene Williams, P.E.
Plot Plan Review (P&D) Approved 04/24/2013 04/22/2013
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,272.90 $1,272.90 Paid 05/02/2013
$1,272.90
9110073-Right of Way Permit Fee $60.00 $60.00 Paid 05/02/2013
$60.00
8331507-Sewer Connection Fee $600.00 $600.00 Paid 05/02/2013
$600.00
8331401-Water Tap Fee $3,085.00 $3,085.00 Paid 05/02/2013
$3,085.00
8350015-Water Meter Fee $253.99 $253.99 Paid 05/02/2013
$253.99
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/7/2013 (11:30) 5/7/2013 at 12:00 AM 05/07/2013
Underslab Plumbing Inspection - Residential Passed 6/14/2013 (8:00 to 5:00) 6/14/2013 at 12:00 AM 06/14/2013
Sewer Service Inspection - R Passed 6/19/2013 (11:30) 6/19/2013 at 12:00 AM 06/19/2013
Water Service Inspection - R Passed 6/19/2013 (11:30) 6/19/2013 at 12:00 AM 06/19/2013
Piers/Caissons Inspection - Residential Failed 7/3/2013 (10:15) 7/3/2013 at 12:00 AM 07/03/2013
Misc
Corrective Action Required
07/03/2013
-CLEAN OUT ALL DEBRIS AND LOOSE DIRT; MAKE SURE THE WEST PIERS ARE DUG DOWN TO GOOD BEARING SOIL
Piers/Caissons Inspection - Residential Passed 7/3/2013 (2:30) 7/3/2013 at 12:00 AM 07/03/2013
Misc
Resolved
07/03/2013
-CLEAN OUT ALL DEBRIS AND LOOSE DIRT; MAKE SURE THE WEST PIERS ARE DUG DOWN TO GOOD BEARING SOIL
Electrical Service Inspection Passed 9/23/2013 at 12:00 AM 09/23/2013
Gas Service Inspection - Residential Not Ready 9/23/2013 at 12:00 AM 09/23/2013
All Rough Inspection - Residential Failed 9/23/2013 9/23/2013 at 12:00 AM 09/23/2013
Misc
Corrective Action Required
09/23/2013
*HAVE PLAN ON SITE *COMPLETE GAS PIPING SYSTEM FRAMING: -NAIL GARAGE PORTAL BRACE WALL SHEATHING TO SILL PLATE -ANCHOR SILL PLATE WITHIN 12" OF BREAK -FIREBLOCKING PER CODE THROUGHOUT-ALL FLOOR PENETRATIONS; ALL VERTICAL SPACES FROM HORIZONTAL SPACES; FIREPLACE WALL SPACE FROM FURDOWN; MASTER AREA WALLS FROM ROOF SPACE; BASEMENT WALL EVERY 10 FT (FILL THE GAP) -EXTERIOR GARAGE DOOR: FILL IN GAP AT HINGES; BLOCK JAMB STUD 3 STUD SPACES OUT -NAIL CORNER STUDS WITH 16D AT 12" INTERVAL OR EQUIVALENT NAILING -TOE-NAIL ALL JOISTS TO WALL TOP PLATES THROUGHOUT WITH MINIMUM 2-12D OR 3-8D -LAG LEDGEBOARD TO I BEAM WEB FRONT DINING -BLOCK UNDERNEATH POINT LOADS OF I BEAM ABOVE FRONT DINING -SHIM GAP AT RAFTER HANGERS ABOVE FRONT ENTRY DOOR -SUPPORT RIDGE EVERY 4 FT ABOVE PILE OF DUCTS BETWEEN FRONT BED AMD MASTER BED -ATTIC ACCESS TO MAIN ROOF -RAFTERS ABOVE MASTER AREA-REDUCE SPAN TO 14'4" -AT MASTER AREA, NAIL SIDING TO STUDS AT STEP FLASHINGS; SNOW-BLOCK STEP FLASHINGS -SUPPORT RIDGE ABOVE HYDROTUB -SUPPORT UNDERNEATH POINT LOAD OF MASTER BED WALL. CHECK PLAN, OR INSTALL DOUBLE JOISTS IF NOT ON PLAN - ELECTRICAL: -SHALL NOT USE WOOD SCREW TO BOND THE GROUNDING BAR TO EXTERIOR SUBPANEL ENCLOSURE. USE HIGH THREAD SCREWS -COMPLETE SOFFIT ELECTRICAL MECHANICAL: -VENT ALL BATHFANS -PAN OFF RETURN AIR FROM ADJACENT SPACES. RA BELOW FRONT DINING (BOTH FLOOR AND WALL RA) PLUMBING: -PROTECT 3" PLUMBING AT MUD CLOSET WALL **DO NOT INSULATE
All Rough Inspection - Residential Failed 9/25/2013 9/25/2013 at 12:00 AM 09/25/2013
Misc
Corrective Action Required
09/23/2013
-RAFTERS ABOVE MASTER AREA-REDUCE SPAN TO 14'4" -SUPPORT RIDGE ABOVE BED ADJACENT TO LAUNDRY TO BEARING WALL PLUMBING: -SHALL PROTECT THE 1" WARDFLEX INSIDE A STRIPWOUND CONDUIT. DO NOT SECURE TO STUD **OK TO INSULATE. DO NOT ROCK
Gas Service Inspection - Residential Failed 9/25/2013 at 12:00 AM 09/25/2013
Misc
Corrective Action Required
09/25/2013
-SEE ALLROUGH INSPECTION
All Rough Inspection - Residential Passed 9/27/2013 at 12:00 AM 09/27/2013
Misc
Resolved
09/27/2013
-RAFTERS ABOVE MASTER AREA-REDUCE SPAN TO 14'4" -SUPPORT RIDGE ABOVE BED ADJACENT TO LAUNDRY TO BEARING WALL PLUMBING: -SHALL PROTECT THE 1" WARDFLEX INSIDE A STRIPWOUND CONDUIT. DO NOT SECURE TO STUD **OK TO INSULATE. DO NOT ROCK
Gas Service Inspection - Residential Passed 9/27/2013 at 12:00 AM 09/27/2013
Misc
Resolved
09/27/2013
-SEE ALLROUGH INSPECTION
Driveway Inspection Passed 11/4/2013 at 1:00 AM 11/12/2013
Sidewalk Inspection Passed 11/12/2013 at 1:00 AM 11/12/2013
Occupancy Inspection - Codes Residential Failed 11/18/2013 11/18/2013 at 12:00 AM 11/18/2013
Misc
Corrective Action Required
11/18/2013
-FINAL GRADE,SOD, AND SPLASHBLOCKS -SEAL EXTERIOR: SEAL ABOVE METER AND ADJACENT ENCLOSURE, SEAL GFCI AT A/C, SEAL LIGHTS -INSTALL REAR STAIR AND HANDRAIL -SECURITY CODE: AT GARAGE SIDE DOOR- INSTALL 3-3" SCREWS AT STRIKE PLATE, INSTALL 2-3" SCREWS AT EACH HINGE, AND INSTALL SECURITY COMPLIANT LIGHT OUTSIDE DOOR; SLIDE DOOR SECONDARY LOCK -RECEPTACLE IN GARAGE SHALL BE GFCI-PROTECTED. ONE NEAR THE SIDE DOOR IS NOT TRIPPING -INSTALL METAL PLATE AT COOKTOP J-BOX; SECURE FLC WITHIN 12" OF J-BOX -COMPLETE INSTALLATION OF GUARDRAILS AND HANDRAIL THROUGHOUT -FIREBLOCK FLOOR PENETRATION AT HYDROTUB TRAP -COMPLETE GAS LINE TO WATER HEATER -REPLACE A/C BREAKER WITH MAX. 45 AMP BREAKERS
Occupancy Inspection - Codes Residential Temporary C of O 11/20/2013 11/20/2013 at 12:00 AM 11/20/2013
Misc
Corrective Action Required
11/18/2013
-FINAL GRADE,SOD, AND SPLASHBLOCKS -SEAL EXTERIOR: SEAL ABOVE METER AND ADJACENT ENCLOSURE, SEAL GFCI AT A/C, SEAL LIGHTS -COMPLETE GAS LINE TO WATER HEATER **GAS TEST REQUIRED
Gas Piping Inspection - Residential Passed 11/22/2013 11/21/2013 at 12:00 AM 11/21/2013
Occupancy Inspection - Codes Residential Full C of O 4/21/2014 at 12:00 AM 04/21/2014
Misc
Resolved
04/21/2014
-FINAL GRADE,SOD, AND SPLASHBLOCKS -SEAL EXTERIOR: SEAL ABOVE METER AND ADJACENT ENCLOSURE, SEAL GFCI AT A/C, SEAL LIGHTS
Documents & Images
Date Uploaded File Type Document Name
05/02/2013 Letter Building Permit
05/02/2013 Plot Plan
05/07/2013 Letter Inspection Summary
06/14/2013 Letter Inspection Summary
06/19/2013 Letter Inspection Summary
07/03/2013 Letter Inspection Summary
07/03/2013 Letter Inspection Summary
07/03/2013 Letter Inspection Summary
09/23/2013 Letter Inspection Summary
09/25/2013 Letter Inspection Summary
09/27/2013 Letter Inspection Summary
11/18/2013 Letter Inspection Summary
11/20/2013 Letter Codes Temporary Certificate of Occupancy
11/21/2013 Letter Inspection Summary
04/21/2014 Letter Field Certificate of Occupancy
04/22/2014 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home