Permit Application Status

PRCOM20152912


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20152912
Building Permit - Commercial
Certificate of Occupancy
CITY OF LEES SUMMIT
NEW COMMERCIAL
NEW AIRCRAFT HANGAR WITH PILOT LOUNGE AND RESTROOM
12/18/2015
04/06/2016
08/27/2016
12/04/2017
Locations
Contacts
THOMPSON BUILDERS LLC, Address:4559 GROVE ST, Phone:(913) 915-2836  
ELKINS A/C & HTG INC, Address:30808 E LITCHFORD RD, Phone:(816) 847-4700  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CASTROP DESIGN GROUP, Address:4318 WEST 54TH ST, Phone:(913) 515-7664  
CITY OF LEES SUMMIT, Address:PO BOX 1600  
KT CONSTRUCTION SERVICES LLC, Address:1332 NE TARA CIR, Phone:(816) 365-6861  
Reviews
Review Type Outcome Est. Completion Date Completed
Final Development Plan Review Approved 03/24/2016
Mike Weisenborn
Licensed Contractors Approved 02/29/2016 03/02/2016
Joe Frogge
Building Plan Review Approved with Conditions 03/07/2016 03/02/2016
Joe Frogge
Final Development Plan
Resolved
03/23/2016

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes. 1/20/16 - acknowledged in letter
Misc
Resolved
03/23/2016

412.4.4 Heating equipment. Heating equipment shall be placed in another room separated by 2-hour fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or both. Entrance shall be from the outside or by means of a vestibule providing a two-doorway separation. Exceptions: 1. Unit heaters and vented infrared radiant heating equipment suspended not less than 10 feet (3048 mm) above the upper surface of wings or engine enclosures of the highest aircraft that are permitted to be housed in the hangar need not be located in a separate room provided they are mounted not less than 8 feet (2438 mm) above the floor in shops, offices and other sections of the hangar communicating with storage or service areas. 2. Entrance to the separated room shall be permitted by a single interior door provided the sources of ignition in the appliances are not less than 18 inches (457 mm) above the floor. Action required: Furnace to be in a room separated by 2 hour barrier. Provide construction details complete with UL. (It may be more economical to extend under floor heating?) 1/20/16 - updated drawings have omitted furnace in lieu of water heater. - - - It is unclear how the exemptions listed on drawings apply to this situation. - - 2/17/16 - Entry door to boiler room moved to exteriror, but the separating structure (wall & ceiling) is still not designated as 2 hour barrier. 3/2/16 - resolved after Joe (me) altered a note on sheet A1 to clarify which walls are required to be fire rated
Fire Plan Review Approved with Conditions 03/03/2016 03/02/2016
Joe Dir
Address numbers required
Corrective Action Required
02/29/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC OF ALPHBETIC BUILDING ADDRESS ON THE BUILDING READABLE FROM THE ROADWAY. VERIFIED AT INSPECTION. (ADDRESSED IN LETTER AND PLANS)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
02/29/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. PROVIDE A MINIMUM OF THREE 2A-10BC ( 5 POUND) FIRE EXTINGUISHERS. VERIFIED AT INSPECTION. MOUNT THE THIRD FIRE EXTINGUISHER ON THE SOUTH WALL BETWEEN THE TWO MAN DOORS (ADDRESSED IN LETTER AND PLANS)
Fire Plan Review Approved with Conditions 02/23/2016 02/18/2016
Joe Dir
Address numbers required
Corrective Action Required
02/16/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC OF ALPHBETIC BUILDING ADDRESS ON THE BUILDING READABLE FROM THE ROADWAY. VERIFIED AT INSPECTION. (ADDRESSED IN LETTER AND PLANS)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
02/16/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. PROVIDE A MINIMUM OF THREE 2A-10BC ( 5 POUND) FIRE EXTINGUISHERS. VERIFIED AT INSPECTION. MOUNT THE THIRD FIRE EXTINGUISHER ON THE SOUTH WALL BETWEEN THE TWO MAN DOORS (ADDRESSED IN LETTER AND PLANS)
Licensed Contractors Approved 02/16/2016 02/17/2016
Joe Frogge
Building Plan Review Rejected 02/23/2016 02/17/2016
Joe Frogge
Final Development Plan
Corrective Action Required
02/16/2016

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes. 1/20/16 - acknowledged in letter
Misc
Resolved
02/16/2016

2012 IBC 1704.2 Special inspections. Where application is made for construction as described in this section, the owner or the registered design professional in responsible charge acting as the owner’s agent shall employ one or more approved agencies to perform inspections during construction on the types of work listed under Section 1705. These inspections are in addition to the inspections identified in Lee’s Summit Code of Ordinances Chapter 7. (see code section for exceptions) Action required: Provide statement of special inspections / letter of responsibility from company contracted to perform special inspections. 1/20/16 - letter received but lacks reference to being responsible for: - testing of concrete - bolts installed in concrete - high strength bolting
Misc
Resolved
02/18/2016

412.4.1 Exterior walls. Exterior walls located less than 30 feet (9144 mm) from lot lines or a public way shall have a fire-resistance rating not less than 2 hours. Action required: Provide UL listed 2 hour fire barrier at north exterior walls within 30 feet of property line. 2/18/16 - per earlier precedents, the 2hr barrier will not be required. Reasoning as I understand it is that we own the property so therefore have control over the construction 1/20/16 - updated drawings reference UL V473. Provide complete construction details including nail/screw patterns as our inspectors do not have UL information available in the field. Also, given that this assembly requires gyp on each side, provide details as to how this will be accomplished and inspected. 2/17/16 - Note has been added referring to an attached drawing that we do not have.
Misc
Corrective Action Required
02/16/2016

412.4.4 Heating equipment. Heating equipment shall be placed in another room separated by 2-hour fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or both. Entrance shall be from the outside or by means of a vestibule providing a two-doorway separation. Exceptions: 1. Unit heaters and vented infrared radiant heating equipment suspended not less than 10 feet (3048 mm) above the upper surface of wings or engine enclosures of the highest aircraft that are permitted to be housed in the hangar need not be located in a separate room provided they are mounted not less than 8 feet (2438 mm) above the floor in shops, offices and other sections of the hangar communicating with storage or service areas. 2. Entrance to the separated room shall be permitted by a single interior door provided the sources of ignition in the appliances are not less than 18 inches (457 mm) above the floor. Action required: Furnace to be in a room separated by 2 hour barrier. Provide construction details complete with UL. (It may be more economical to extend under floor heating?) 1/20/16 - updated drawings have omitted furnace in lieu of water heater. - - - It is unclear how the exemptions listed on drawings apply to this situation. - - 2/17/16 - Entry door to boiler room moved to exteriror, but the separating structure (wall & ceiling) is still not designated as 2 hour barrier.
Misc
Resolved
02/17/2016

412.4.3 Floor surface. Floors shall be graded and drained to prevent water or fuel from remaining on the floor. Floor drains shall discharge through an oil separator to the sewer or to an outside vented sump. (see code for exceptions) Action required: Provide oil separator at DWV piping system that serves trench drain. 1/20/16 - Specify oil separator size and provide installation details. 2/17/16 - separator omitted. floor slopes to o.h. door
Misc
Resolved
02/17/2016

Mechanical design incomplete. Action required: Provide specifications for under floor heating system. Provide complete HVAC design at office area complete with, but not limited to, duct sizes, furnace specifications, furnace support, etc. 1/20/16 - reference comment #5 for heating equipment.
Special Inspections Review Approved 02/16/2016
Joe Frogge
Fire Plan Review Approved with Conditions 01/26/2016 01/21/2016
Joe Dir
Address numbers required
Corrective Action Required
01/19/2016

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC OF ALPHBETIC BUILDING ADDRESS ON THE BUILDING READABLE FROM THE ROADWAY. VERIFIED AT INSPECTION. (ADDRESSED IN LETTER AND PLANS)
Portable fire extinguishers - conspicuous locations
Corrective Action Required
01/19/2016

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. PROVIDE A MINIMUM OF TWO 2A-10BC ( 5 POUND) FIRE EXTINGUISHERS. VERIFIED AT INSPECTION. (ADDRESSED IN LETTER AND PLANS)
Building Plan Review Rejected 01/26/2016 01/20/2016
Joe Frogge
Final Development Plan
Corrective Action Required
01/19/2016

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes. 1/20/16 - acknowledged in letter
Code analysis required
Resolved
01/20/2016

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis as noted. 1/20/16 - provided on revised sheet
Misc
Corrective Action Required
01/19/2016

2012 IBC 1704.2 Special inspections. Where application is made for construction as described in this section, the owner or the registered design professional in responsible charge acting as the owner’s agent shall employ one or more approved agencies to perform inspections during construction on the types of work listed under Section 1705. These inspections are in addition to the inspections identified in Lee’s Summit Code of Ordinances Chapter 7. (see code section for exceptions) Action required: Provide statement of special inspections / letter of responsibility from company contracted to perform special inspections. 1/20/16 - letter received but lacks reference to being responsible for: - testing of concrete - bolts installed in concrete - high strength bolting
Misc
Corrective Action Required
01/19/2016

412.4.1 Exterior walls. Exterior walls located less than 30 feet (9144 mm) from lot lines or a public way shall have a fire-resistance rating not less than 2 hours. Action required: Provide UL listed 2 hour fire barrier at north exterior walls within 30 feet of property line. 1/20/16 - updated drawings reference UL V473. Provide complete construction details including nail/screw patterns as our inspectors do not have UL information available in the field. Also, given that this assembly requires gyp on each side, provide details as to how this will be accomplished and inspected.
Misc
Corrective Action Required
01/19/2016

412.4.4 Heating equipment. Heating equipment shall be placed in another room separated by 2-hour fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or both. Entrance shall be from the outside or by means of a vestibule providing a two-doorway separation. Exceptions: 1. Unit heaters and vented infrared radiant heating equipment suspended not less than 10 feet (3048 mm) above the upper surface of wings or engine enclosures of the highest aircraft that are permitted to be housed in the hangar need not be located in a separate room provided they are mounted not less than 8 feet (2438 mm) above the floor in shops, offices and other sections of the hangar communicating with storage or service areas. 2. Entrance to the separated room shall be permitted by a single interior door provided the sources of ignition in the appliances are not less than 18 inches (457 mm) above the floor. Action required: Furnace to be in a room separated by 2 hour barrier. Provide construction details complete with UL. (It may be more economical to extend under floor heating?) 1/20/16 - updated drawings have omitted furnace in lieu of water heater. - Information is still inadequate for approval. Provide complete design. (information provided was for the heating equipment only) - If this heater is to be used for domestic water provide details as to how the domestic water system will be protected. - It is unclear how the exemptions listed on drawings apply to this situation. - If nonpotable water is utilized it must be identified per IPC 608.8 - Given the lack of a complete design, this review is cursory and incomplete. i.e. more review comments are possible upon submission.
Misc
Corrective Action Required
01/19/2016

412.4.3 Floor surface. Floors shall be graded and drained to prevent water or fuel from remaining on the floor. Floor drains shall discharge through an oil separator to the sewer or to an outside vented sump. (see code for exceptions) Action required: Provide oil separator at DWV piping system that serves trench drain. 1/20/16 - Specify oil separator size and provide installation details.
Engineered truss package
Resolved
01/20/2016

Copies of the pre-engineered metal building package were not provided at the time of permit application. Action required: Provide steel building package or request to defer to construction. 1/20/16 - provided
Misc
Resolved
01/20/2016

Interior walls not specified. Action required: Provide construction details for interior walls. 1/20/16 - provided
Accessibility - Water closet clearance width 604.3.1
Resolved
01/20/2016

ICC A117.1-2009 604.3.1 – Clearance width. Clearance around a water closet shall be 60 inches minimum in width, measured perpendicular from the sidewall. Action required: Modify restroom design to demonstrate compliance. 1/20/16 - provided
Accessibility - Flush controls 604.6
Resolved
01/20/2016

ICC A117.1-2009 604.6 – Flush controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with Section 309. Flush controls shall be located on the open side of the water closet. Action required: Modify restroom design to demonstrate compliance. 1/20/16 - provided
Accessibility - Swinging doors - restrooms404.2.3.2
Resolved
01/20/2016

ICC A117.1-2009 Section 603.2.2 Door Swing. Doors shall not swing into the clear floor space or clearance for any fixture. (see code for exceptions) Action required: Modify restroom design to demonstrate compliance. 1/20/16 - provided
Bldg - Accessibility - Continuity and components 1007.2
Resolved
01/20/2016

2012 IBC 1007.2 – Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components: 1. Accessible routes complying with Section 1104. 2. Interior exit stairways complying with Sections 1007.3 and 1022. 3. Interior exit access stairways complying with Sections 1007.3 and 1009.3. 4. Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge. 5. Elevators complying with Section 1007.4. 6. Platform lifts complying with Section 1007.5. 7. Horizontal exits complying with Section 1025. 8. Ramps complying with Section 1010. 9. Areas of refuge complying with Section 1007.6. 10. Exterior area for assisted rescue complying with Section 1007.7. Action required: Specify method and location of accessible entry. 1/20/16 - provided
Misc
Corrective Action Required
01/19/2016

Mechanical design incomplete. Action required: Provide specifications for under floor heating system. Provide complete HVAC design at office area complete with, but not limited to, duct sizes, furnace specifications, furnace support, etc. 1/20/16 - reference comment #5 for heating equipment.
Misc
Resolved
01/20/2016

2011 NEC 210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 25 feet of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. Action required: Provide exterior convenience receptacle within 25' of condensing unit. 1/20/16 - provided
Licensed Contractors Approved 01/19/2016 01/20/2016
Joe Frogge
Fire Plan Review Approved with Conditions 01/05/2016 01/05/2016
Joe Dir
Address numbers required
Corrective Action Required
12/22/2015

2012 IFC 505.1- Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. In Multi-tenant commercial building where tenants have multiple entrances located on different sides of the building , each door shall be addressed. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). POST THE NUMERIC OF ALPHBETIC BUILDING ADDRESS ON THE BUILDING READABLE FROM THE ROADWAY. VERIFIED AT INSPECTION.
Portable fire extinguishers - conspicuous locations
Corrective Action Required
12/22/2015

2012 IFC 906.5- Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. PROVIDE A MINIMUM OF TWO 2A-10BC ( 5 POUND) FIRE EXTINGUISHERS. VERIFIED AT INSPECTION.
Building Plan Review Rejected 01/05/2016 12/31/2015
Joe Frogge
Final Development Plan
Corrective Action Required
12/31/2015

The building permit for this project can not be issued until the Codes Administration Department has received the approved Final Development Plan from the Planning and Development Department. Action required: Comment is for informational purposes.
Code analysis required
Corrective Action Required
12/31/2015

A code analysis shall be provided which includes but is not limited to occupancy type, occupant load, construction type, actual area, height and floors, allowable area, height and floors, and the codes to which the project is designed. Action required: Provide code analysis as noted.
Misc
Corrective Action Required
12/31/2015

2012 IBC 1704.2 Special inspections. Where application is made for construction as described in this section, the owner or the registered design professional in responsible charge acting as the owner’s agent shall employ one or more approved agencies to perform inspections during construction on the types of work listed under Section 1705. These inspections are in addition to the inspections identified in Lee’s Summit Code of Ordinances Chapter 7. (see code section for exceptions) Action required: Provide statement of special inspections / letter of responsibility from company contracted to perform special inspections.
Misc
Corrective Action Required
12/31/2015

412.4.1 Exterior walls. Exterior walls located less than 30 feet (9144 mm) from lot lines or a public way shall have a fire-resistance rating not less than 2 hours. Action required: Provide UL listed 2 hour fire barrier at north exterior walls within 30 feet of property line.
Misc
Corrective Action Required
12/31/2015

412.4.4 Heating equipment. Heating equipment shall be placed in another room separated by 2-hour fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or both. Entrance shall be from the outside or by means of a vestibule providing a two-doorway separation. Exceptions: 1. Unit heaters and vented infrared radiant heating equipment suspended not less than 10 feet (3048 mm) above the upper surface of wings or engine enclosures of the highest aircraft that are permitted to be housed in the hangar need not be located in a separate room provided they are mounted not less than 8 feet (2438 mm) above the floor in shops, offices and other sections of the hangar communicating with storage or service areas. 2. Entrance to the separated room shall be permitted by a single interior door provided the sources of ignition in the appliances are not less than 18 inches (457 mm) above the floor. Action required: Furnace to be in a room separated by 2 hour barrier. Provide construction details complete with UL. (It may be more economical to extend under floor heating?)
Misc
Corrective Action Required
12/31/2015

412.4.3 Floor surface. Floors shall be graded and drained to prevent water or fuel from remaining on the floor. Floor drains shall discharge through an oil separator to the sewer or to an outside vented sump. (see code for exceptions) Action required: Provide oil separator at DWV piping system that serves trench drain.
Engineered truss package
Corrective Action Required
12/31/2015

Copies of the pre-engineered metal building package were not provided at the time of permit application. Action required: Provide steel building package or request to defer to construction.
Misc
Corrective Action Required
12/31/2015

Interior walls not specified. Action required: Provide construction details for interior walls.
Accessibility - Water closet clearance width 604.3.1
Corrective Action Required
12/31/2015

ICC A117.1-2009 604.3.1 – Clearance width. Clearance around a water closet shall be 60 inches minimum in width, measured perpendicular from the sidewall. Action required: Modify restroom design to demonstrate compliance.
Accessibility - Flush controls 604.6
Corrective Action Required
12/31/2015

ICC A117.1-2009 604.6 – Flush controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with Section 309. Flush controls shall be located on the open side of the water closet. Action required: Modify restroom design to demonstrate compliance.
Accessibility - Swinging doors - restrooms404.2.3.2
Corrective Action Required
12/31/2015

ICC A117.1-2009 Section 603.2.2 Door Swing. Doors shall not swing into the clear floor space or clearance for any fixture. (see code for exceptions) Action required: Modify restroom design to demonstrate compliance.
Bldg - Accessibility - Continuity and components 1007.2
Corrective Action Required
12/31/2015

2012 IBC 1007.2 – Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components: 1. Accessible routes complying with Section 1104. 2. Interior exit stairways complying with Sections 1007.3 and 1022. 3. Interior exit access stairways complying with Sections 1007.3 and 1009.3. 4. Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge. 5. Elevators complying with Section 1007.4. 6. Platform lifts complying with Section 1007.5. 7. Horizontal exits complying with Section 1025. 8. Ramps complying with Section 1010. 9. Areas of refuge complying with Section 1007.6. 10. Exterior area for assisted rescue complying with Section 1007.7. Action required: Specify method and location of accessible entry.
Misc
Corrective Action Required
12/31/2015

Mechanical design incomplete. Action required: Provide specifications for under floor heating system. Provide complete HVAC design at office area complete with, but not limited to, duct sizes, furnace specifications, furnace support, etc. Specify restroom exhaust fan complete with duct and termination information.
Misc
Corrective Action Required
12/31/2015

2011 NEC 210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet. A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 25 feet of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means. Action required: Provide exterior convenience receptacle within 25' of condensing unit.
Licensed Contractors Approved 01/05/2016 12/18/2015
Joe Frogge
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Commercial $1,083.00 $1,083.00 Paid 04/06/2016
8331507-Sewer Connection Fee $90.00 $90.00 Paid 04/06/2016
8331401-Water Tap Fee $3,214.00 $3,214.00 Paid 04/06/2016
8350015-Water Meter Fee $377.18 $377.18 Paid 04/06/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection Partial 9/12/2016 (1:15) 9/12/2016 09/12/2016
Sewer Service Inspection Failed 9/12/2016 09/12/2016
Misc
Corrective Action Required
09/12/2016
-SEWER HOLDING TANK TOO CLOSE TO THE FOOTING, UNDERMINING THE FOOTING. HAVE ENGINEER ADDRESS THIS
Water Service Inspection Passed 9/13/2016 (9:45) 9/13/2016 09/13/2016
Occupancy Inspection - Planning Temporary C of O 12/13/2016
Corrective Action Required
12/13/2016
LIGHT FIXTURES. The wall packs do not meet the ordinance requirement for having full 90 degree cut-offs. The type of fixture submitted for approval as part of the final development plan was identical to the fixtures used on the adjacent hangar to the immediate south. Please refer to the wall packs on the adjacent building referenced above.
Corrective Action Required
12/13/2016
ADA PARKING SPACE. The ADA accessible parking space shall be posted with a type R7-8 sign (as identified in the Manual of Uniform Traffic Control Devices) mounted onto the buiding directly in front of the space. The R7-8 sign has a white background, blue wheelchair symbol, green text and green border.
Corrective Action Required
12/13/2016
LANDSCAPING. The disturbed areas on the north and west sides of the hangar shall be sodded.
Occupancy Inspection - Fire Temporary C of O 12/13/2016 12/13/2016
Sewer Service Inspection Passed 12/13/2016
Misc
Resolved
12/13/2016
-SEWER HOLDING TANK TOO CLOSE TO THE FOOTING, UNDERMINING THE FOOTING. HAVE ENGINEER ADDRESS THIS **SEE FINAL REPORT
Occupancy Inspection - Codes Commercial Temporary C of O 12/13/2016 12/13/2016 12/13/2016
Misc
Corrective Action Required
12/13/2016
-LICENSED TAX HAS NOT BEEN PAID -APPROVAL REQUIRED FROM: FIRE, PLANNING, PUBLIC WORKS -SUBMIT 3RD PARTY SPECIAL INSPECTION APPROVAL LETTER FOR: SOIL BEARING, CONCRETE, STEEL FRAMING, SEWER HOLDING TANK CLOSE TO THE FOOTING -SOD DISTURBED AREA -INSTALL SPLASHBLOCKS OUTSIDE -WINDOWS BY REAR DOOR MUST BE SAFTY TEMPERED WINDOWS -COMPLETE ELECTRICAL SERVICE AND ALL CIRCUITS; LIGHTS AT EXTERIOR DOORS; SECURE MC WITHIN 12" OF BOX; COMPLETE WATER SERVICE ***BUILDING OK FOR AIRCRAFT STORAGE ONLY
In-wall Inspection Failed 2/28/2017 3/9/2017 03/09/2017
Misc
Corrective Action Required
03/09/2017
-PROVIDE CITY APPROVED PLAN ON SITE -PROTECT ALL PLUMBING PER CODE -SECURELY FASTEN ALL MC CABLES WITHIN 12" OF ALL BOXES AND ENCLOSURES AND AT INTERVAL NOT MORE THAN 6 FT -SECURE EMT WITHIN 3 FT OF PANEL -PROVIDE EM EXIT LIGHTING AND EXIT DISCHARGE -BOND ALL METAL BOXES -INSTALL BUSHING AT EMT ENTRY INTO PANEL -ID GROUNDED CONDUCTOR PER CODE -INSTALL PROPER DRAINAGE FITTING PER CODE -INSTALL MID-WALL HEIGHT SUPPORT FOR 2" OR SMALLER PVC INSIDE WALL -REMOVE ALL CONSTRUCTION DEBRIS OUT OF WALL SPACE -VENT PLUMBING FIXTURES PER CODE -OPEN PLUMBING INSIDE WALL SPACE -SECURELY SUPPORT PEX WATER LINES PER CODE -RESTROOM SHALL COMPLY WITH ADA/ANSI 117 -INSTALL BLOCKINGS FOR GRAB BARS PER ANSI 117 -VENT BATH FAN ***PLUMBER LICENSED???
Electrical Service Inspection Failed 2/28/2017 4/17/2017 04/17/2017
Misc
Corrective Action Required
04/17/2017
-PROTECT GROUNDING ELECTRODE CONDUCTOR INSIDE A RACEWAY WHERE IT IS EXPOSED TO DAMAGE -BOND SERVICE PANEL ENCLOSURE -TAPE THE SERVICE GROUNDED CONDUCTOR WITH PROPER COLOR -INSTALL INSULATING BUSHINGS AT ALL EMT ENTRIES INTO THE PANEL FOR CONDUCTORS #4 OR LARGER -TOO MANY CONDUCTORS INSIDE THE SAME EMT RACEWAY. CONDUCTORS SHALL BE DE-RATED. 7-9 CURRENT-CARRYING CONDUCTORS INSIDE THE SAME RACEWAY ARE NOW AT 70% AMPACITY -CANNOT INSTALL WESTINGHOUSE BREAKERS IN THE EATON PANEL
In-wall Inspection Failed 4/17/2017 04/17/2017
Misc
Corrective Action Required
03/09/2017
-PROVIDE CITY APPROVED PLAN ON SITE -PROTECT ALL PLUMBING PER CODE -SECURELY FASTEN ALL MC CABLES WITHIN 12" OF ALL BOXES AND ENCLOSURES AND AT INTERVAL NOT MORE THAN 6 FT -SECURE EMT WITHIN 3 FT OF PANEL -BOND ALL METAL BOXES -INSTALL BUSHING AT EMT ENTRY INTO PANEL -ID GROUNDED CONDUCTOR PER CODE -RESTROOM SHALL COMPLY WITH ADA/ANSI 117 -INSTALL BLOCKINGS FOR GRAB BARS PER ANSI 117 ***PLUMBER LICENSED???
Occupancy Inspection - Codes Commercial Failed 4/17/2017 4/17/2017 04/17/2017
Misc
Corrective Action Required
12/13/2016
-LICENSED TAX HAS NOT BEEN PAID -APPROVAL REQUIRED FROM: FIRE, PLANNING, PUBLIC WORKS -SOD DISTURBED AREA -WINDOWS BY REAR DOOR MUST BE SAFTY TEMPERED WINDOWS ***DO NOT CLOSE UNTIL FIRE HYDRANT HAS BEEN RAISED***** ***BUILDING OK FOR AIRCRAFT STORAGE ONLY
Occupancy Inspection - Fire Failed 4/17/2017 04/17/2017
Electrical Service Inspection Failed 4/27/2017 4/27/2017 04/27/2017
Misc
Corrective Action Required
04/17/2017
-PROTECT GROUNDING ELECTRODE CONDUCTOR INSIDE A RACEWAY WHERE IT IS EXPOSED TO DAMAGE -BOND SERVICE PANEL ENCLOSURE -INSTALL INSULATING BUSHINGS AT ALL EMT ENTRIES INTO THE PANEL FOR CONDUCTORS #4 OR LARGER
In-wall Inspection Failed 4/27/2017 4/27/2017 04/27/2017
Misc
Corrective Action Required
04/17/2017
-SECURE EMT WITHIN 3 FT OF PANEL -BOND ALL METAL BOXES **BOND THE SWITCHBOX IN RESTROOM -INSTALL BUSHINGS AT EMT ENTRY INTO PANEL **CUT BUSHINGS -INSTALL BLOCKINGS FOR GRAB BARS PER ANSI 117
In-wall Inspection Partial 5/3/2017 05/03/2017
Misc
Corrective Action Required
04/27/2017
-INSTALL BLOCKINGS FOR GRAB BARS PER ANSI 117 **MAKE SURE TO HAVE THE BLOCKING FOR THE REAR GRAB BAR, AS WELL AS THE 18" VERTICAL GRAB BAR **OK TO ROCK
Electrical Service Inspection Passed 5/3/2017 05/03/2017
Misc
Resolved
05/03/2017
-PROTECT GROUNDING ELECTRODE CONDUCTOR INSIDE A RACEWAY WHERE IT IS EXPOSED TO DAMAGE -BOND SERVICE PANEL ENCLOSURE -INSTALL INSULATING BUSHINGS AT ALL EMT ENTRIES INTO THE PANEL FOR CONDUCTORS #4 OR LARGER
In-wall Inspection Passed 09/26/2017
Misc
Resolved
09/26/2017
-INSTALL BLOCKINGS FOR GRAB BARS PER ANSI 117 **MAKE SURE TO HAVE THE BLOCKING FOR THE REAR GRAB BAR, AS WELL AS THE 18" VERTICAL GRAB BAR **OK TO ROCK
Occupancy Inspection - Codes Commercial Failed 9/26/2017 9/26/2017 at 8:55 AM 09/26/2017
Misc
Corrective Action Required
04/17/2017
-LICENSED TAX HAS NOT BEEN PAID -APPROVAL REQUIRED FROM: FIRE, PLANNING, PUBLIC WORKS -INSTALL MIN. 3 FT DOWNSPOUT EXTENSIONS -EXTERIOR RECEPTACLE SHALL BE GFCI-PROTECTED -RESTROOM: INSTALL NON-ABSORBANT WALL BASE; WALL MUST HAVE NON-ABSORBANT WALL FINISH PAINT -SUPPORT RECEPTACLE AT BAR SINK -ALL BOXES RECESSED BEHIND THE COMBUSTIBLE WALL FINISH SHALL HAVE SPARK-RING EXTENSIONS -INSTALL ANTI-BACKFLOW FOR HOSE BIBB -AC UNIT: INSTALL MAXIMUM 15 AMP BREAKER FOR AC UNIT; SECURE AC WHIP WITHIN 12" OF DISCONNECT; INSTALL CONDUCTORS RATED FOR WET LOCATION FOR THE WHIP CONDUCTORS; ID UNGROUNDED CONDUCTOR WITH PROPER COLOR; SEAL AC LINE PENETRATION OF THE EXTERIOR WALL;
Occupancy Inspection - Planning Temporary C of O 9/26/2017 09/26/2017
Corrective Action Required
09/26/2017
LIGHT FIXTURES. The wall packs do not meet the ordinance requirement for having full 90 degree cut-offs. The type of fixture submitted for approval as part of the final development plan was identical to the fixtures used on the adjacent hangar to the immediate south. Please refer to the wall packs on the adjacent building referenced above.
Corrective Action Required
09/26/2017
ADA PARKING SPACE. The ADA accessible parking space shall be posted with a type R7-8 sign (as identified in the Manual of Uniform Traffic Control Devices) mounted onto the buiding directly in front of the space. The R7-8 sign has a white background, blue wheelchair symbol, green text and green border.
Occupancy Inspection - Fire Temporary C of O 9/26/2017 09/26/2017
Occupancy Inspection - Fire Passed 11/3/2017 11/03/2017
Occupancy Inspection - Codes Commercial Failed 11/7/2017 11/7/2017 at 10:30 AM 11/07/2017
Misc
Corrective Action Required
09/26/2017
-APPROVAL REQUIRED FROM: PLANNING AND DEVELOPMENT ENGINEER INSPECTION -EXTERIOR RECEPTACLE SHALL BE GFCI-PROTECTED **FRONT RECEPTACLE -ALL BOXES RECESSED BEHIND THE COMBUSTIBLE WALL FINISH SHALL HAVE SPARK-RING EXTENSIONS **THE SWITCHBOX -AC UNIT: INSTALL CONDUCTORS RATED FOR WET LOCATION FOR THE WHIP CONDUCTORS; ID UNGROUNDED CONDUCTOR WITH PROPER COLOR **THE NM CABLE IS NOT RATED FOR WET LOCATION
Occupancy Inspection - Engineering Passed 11/7/2017 11/07/2017
Occupancy Inspection - Planning Temporary C of O 11/7/2017 11/07/2017
Misc
Corrective Action Required
11/07/2017
The exterior light fixtures located on the south wall of the building do not meet the requirements for zero cut off. Action required - Make needed corrections.
Misc
Corrective Action Required
11/07/2017
The required accessible parking space is not properly marked. Action Required - Installe required pavement and wall signage as shown on the approved final development plan.
Occupancy Inspection - Planning Temporary C of O 11/9/2017 11/09/2017
Misc
Corrective Action Required
11/09/2017
LIGHT FIXTURES. The wall packs do not meet the ordinance requirement for having full 90 degree cut-offs. The type of fixture submitted for approval as part of the final development plan was identical to the fixtures used on the adjacent hangar to the immediate south. Please refer to the wall packs on the adjacent building referenced above.
Misc
Corrective Action Required
11/09/2017
ADA PARKING SPACE. The ADA accessible parking space shall be posted with a type R7-8 sign (as identified in the Manual of Uniform Traffic Control Devices) mounted onto the buiding directly in front of the space. The R7-8 sign has a white background, blue wheelchair symbol, green text and green border.
Occupancy Inspection - Engineering Passed 11/9/2017 11/09/2017
Occupancy Inspection - Codes Commercial Failed 11/9/2017 11/9/2017 at 10:10 AM 11/09/2017
Misc
Corrective Action Required
11/07/2017
-APPROVAL REQUIRED FROM: PLANNING **NOTHING IS DONE -EXTERIOR RECEPTACLE SHALL BE GFCI-PROTECTED **THE FRONT EXTERIOR GFCI RECEPTACLE IS REPLACED, BUT THE WEATHER PROOF COVER IS MISSING THE HINGE ROD -ALL BOXES RECESSED BEHIND THE COMBUSTIBLE WALL FINISH SHALL HAVE SPARK-RING EXTENSIONS **THE SWITCHBOX
Occupancy Inspection - Planning Passed 11/17/2017 11/21/2017
Misc
Corrective Action Required
11/09/2017
LIGHT FIXTURES. The wall packs do not meet the ordinance requirement for having full 90 degree cut-offs. The type of fixture submitted for approval as part of the final development plan was identical to the fixtures used on the adjacent hangar to the immediate south. Please refer to the wall packs on the adjacent building referenced above.
Misc
Corrective Action Required
11/09/2017
ADA PARKING SPACE. The ADA accessible parking space shall be posted with a type R7-8 sign (as identified in the Manual of Uniform Traffic Control Devices) mounted onto the buiding directly in front of the space. The R7-8 sign has a white background, blue wheelchair symbol, green text and green border.
Occupancy Inspection - Codes Commercial Full C of O 11/17/2017 12/4/2017 12/04/2017
Misc
Resolved
12/04/2017
-APPROVAL REQUIRED FROM: PLANNING **NOTHING IS DONE -EXTERIOR RECEPTACLE SHALL BE GFCI-PROTECTED **THE FRONT EXTERIOR GFCI RECEPTACLE IS REPLACED, BUT THE WEATHER PROOF COVER IS MISSING THE HINGE ROD -ALL BOXES RECESSED BEHIND THE COMBUSTIBLE WALL FINISH SHALL HAVE SPARK-RING EXTENSIONS **THE SWITCHBOX
Documents & Images
Date Uploaded File Type Document Name
12/22/2015 Letter Fire Building Plan Review
01/05/2016 Letter Codes P/R Corrections Document
01/21/2016 Letter Fire Building Plan Review
01/21/2016 Letter Codes P/R Corrections Document
02/18/2016 Letter Fire Building Plan Review
02/19/2016 Letter Codes P/R Corrections Document
03/02/2016 Letter Fire Building Plan Review
03/23/2016 Letter Codes Plan Review Conditions
04/06/2016 Receipt Receipt for transaction: 2016-001010
04/06/2016 Letter Codes Building Permit
09/12/2016 Letter Inspection Summary
09/13/2016 Letter Inspection Summary
12/13/2016 Letter Codes Temporary Certificate of Occupancy
03/09/2017 Letter Inspection Summary
04/17/2017 Letter Inspection Summary
04/27/2017 Letter Inspection Summary
05/03/2017 Letter Inspection Summary
07/11/2017 Letter Codes 10 Day Letter
09/26/2017 Letter Inspection Summary
11/07/2017 Letter Inspection Summary
11/07/2017 Letter Inspection Summary
11/09/2017 Letter Inspection Summary
12/04/2017 Letter Field Certificate of Occupancy
12/05/2017 Letter Codes Final Certificate of Occupancy
02/27/2018 16-0915 Wahl Hanger 15182 Letter
02/27/2018 16-1214-
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home